- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
xindun power
-
Model Number:
-
XD-DP Power Inverter with Charger
-
Output Frequency:
-
Low frequency 50/60Hz±1%
-
Size:
-
620*345*255~680*365*280(mm)
-
Weight:
-
17KG~38KG
-
Application:
-
Off-grid area, every field
-
Battery type:
-
Lead Acid/GEL/AGM/LiFePO4/Lithium
-
Warranty:
-
1-2 Year
-
Service:
-
OEM Service Offered
-
Rated power:
-
1000w 1500w 2000w 3000w 4000w 5000w 6000w 7000w inverter
-
Protection:
-
Overload,over voltage,short circuit
-
Color:
-
White
-
Display:
-
LCD
-
Output waveform:
-
Pure Sine Wave Solar Inverter
-
Product name:
-
Low frequency power inverter with charger
-
Certificate:
-
CE RoHS TUV IEC
Quick Details
-
Output Current:
-
Load
-
Customized support:
-
yes
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
xindun power
-
Model Number:
-
XD-DP Power Inverter with Charger
-
Output Frequency:
-
Low frequency 50/60Hz±1%
-
Size:
-
620*345*255~680*365*280(mm)
-
Weight:
-
17KG~38KG
-
Application:
-
Off-grid area, every field
-
Battery type:
-
Lead Acid/GEL/AGM/LiFePO4/Lithium
-
Warranty:
-
1-2 Year
-
Service:
-
OEM Service Offered
-
Rated power:
-
1000w 1500w 2000w 3000w 4000w 5000w 6000w 7000w inverter
-
Protection:
-
Overload,over voltage,short circuit
-
Color:
-
White
-
Display:
-
LCD
-
Output waveform:
-
Pure Sine Wave Solar Inverter
-
Product name:
-
Low frequency power inverter with charger
-
Certificate:
-
CE RoHS TUV IEC
1. Low frequency toroidal transformer increase efficiency,Pure sine wave output;
2. Integrated LCD display; One-button start with an external display screen( optional);
3. Dedicated DCP chip design; stable and high-speed operation;
4. LCD display, easy to monitor the operation condition in real time;
5. AC charge current 0-30A adjustable; battery capacity configuration more flexible;
6. Three types working modes adjustable:AC first, DC first, energy-saving mode;
7. AVR output, all-around automatic protection function;
8. Built-in PWM or MPPT controller optional;
9. Added fault codes query function,facilitate user to monitor the operation state in real time;
10. Supports diesel or gasoline generator, adapt any tough electricity situation;
11. RS485 communication port/APP optional.
Highlight
Product Description
Specification
Specification
|
|
|
|
|
|
|
|
|
|
|||||||||
Model: DP/DP-T
|
|
10212/24/48
|
15212/24/48
|
20212/24/48
|
30224/48
|
40224/48
|
50248
|
60248
|
70248
|
|||||||||
Rated Power
|
|
1000W
|
1500W
|
2000W
|
3000W
|
4000W
|
5000W
|
6000W
|
7000W
|
|||||||||
Peak Power(20ms)
|
|
3000VA
|
4500VA
|
6000VA
|
9000VA
|
12000VA
|
15000VA
|
18000VA
|
21000VA
|
|||||||||
Start Motor
|
|
1HP
|
1.5HP
|
2HP
|
3HP
|
3HP
|
4HP
|
4HP
|
5HP
|
|||||||||
Battery Voltage
|
|
12/24/48VDC
|
|
|
24/48VDC
|
24/48VDC
|
48VDC
|
|
|
|||||||||
Size(L*W*Hmm)
|
|
555*297*184
|
|
|
|
615*315*209
|
|
|
|
|||||||||
Packing Size(L*W*Hmm)
|
|
620*345*255
|
|
|
|
680*365*280
|
|
|
|
|||||||||
N.W.(kg)
|
|
12
|
13
|
15.5
|
18
|
23
|
24.5
|
26
|
27.5
|
|||||||||
G.W.(kg)(Carton Packing)
|
|
14
|
15
|
17.5
|
20
|
25.5
|
27
|
28.5
|
30
|
|||||||||
Installation Method
|
|
Wall-Mounted
|
|
|
|
|
|
|
|
|||||||||
Parameter
|
|
|
|
|
|
|
|
|
|
|||||||||
Input
|
DC Input Voltage Range
|
10.5-15VDC(Single battery voltage)
|
|
|
|
|
|
|
|
|||||||||
|
AC Input Voltage Range
|
85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC)
/ 190VAC~295VAC(240VAC) |
|
|
|
|
|
|
|
|||||||||
|
AC Input Frequency Range
|
45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
|
|
|
|
|
|
|
|
|||||||||
|
Max AC charging current
|
0~30A(Depending on the model)
|
|
|
|
|
|
|
|
|||||||||
|
AC charging method
|
Three-stage (constant current, constant voltage, floating charge)
|
|
|
|
|
|
|
|
|||||||||
Output
|
Efficiency(Battery Mode)
|
≥85%
|
|
|
|
|
|
|
|
|||||||||
|
Output Voltage(Battery Mode)
|
110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%
|
|
|
|
|
|
|
|
|||||||||
|
Output Frequency(Battery Mode)
|
50/60Hz±1%
|
|
|
|
|
|
|
|
|||||||||
|
Output Wave(Battery Mode)
|
Pure Sine Wave
|
|
|
|
|
|
|
|
|||||||||
|
Efficiency(AC Mode)
|
>99%
|
|
|
|
|
|
|
|
|||||||||
|
Output Voltage(AC Mode)
|
110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%
|
|
|
|
|
|
|
|
|||||||||
|
Output Frequency(AC Mode)
|
Follow input
|
|
|
|
|
|
|
|
|||||||||
|
Output waveform distortion
(Battery Mode) |
≤3%(Linear load)
|
|
|
|
|
|
|
|
|||||||||
|
No load loss(Battery Mode)
|
≤0.8% rated power
|
|
|
|
|
|
|
|
|||||||||
|
No load loss(AC Mode)
|
≤2% rated power( charger does not work in AC mode)
|
|
|
|
|
|
|
|
|||||||||
|
No load loss(Energy saving Mode)
|
≤10W
|
|
|
|
|
|
|
|
|||||||||
Battery Type
|
VRLA Battery
|
Charge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
|
|
|
|
|
|
|
|
|||||||||
|
Customize battery
|
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
|
|
|
|
|
|
|
|||||||||
Protection
|
Battery undervoltage alarm / Battery undervoltage protection / Battery overvoltage alarm / Battery overvoltage protection / Battery overvoltage recovery voltage / Overload power protection / Inverter output short circuit protection / Temperature protection
|
|
|
|
|
|
|
|
|
|||||||||
Alarm
|
A
|
Normal working condition, buzzer has no alarm sound
|
|
|
|
|
|
|
|
|||||||||
|
B
|
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
|
|
|
|
|
|
|
|
|||||||||
|
C
|
When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
|
|
|
|
|
|
|
|
|||||||||
Inside Solar controller
(Optional) |
Charging Mode
|
PWM or MPPT
|
|
|
|
|
|
|
|
|||||||||
|
Charging current
|
10A~60A(PWM or MPPT)
|
|
|
|
10A~60A(PWM ) / 10A~100A(MPPT)
|
|
|
|
|||||||||
|
PV Input Voltage Range
|
PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system) |
|
|
|
|
|
|
|
|||||||||
|
Max PV Input Voltage(Voc)
(At the lowest temperature) |
PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system)
|
|
|
|
|
|
|
|
|||||||||
|
PV Array Maximum Power
|
12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A);
48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A) |
|
|
|
|
|
|
|
|||||||||
|
Standby loss
|
≤3W
|
|
|
|
|
|
|
|
|||||||||
|
Maximum conversion efficiency
|
>95%
|
|
|
|
|
|
|
|
Wiring Diagram
1. We offer 3 optional working modes (transfer time≤4ms):
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
Application
Packing & Delivery