- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
BK-GLH01
-
Place of Origin:
-
Shandong, China
-
Name:
-
Auto Glycated Hemoglobin HbA1c Analyzer
-
Model:
-
BK-GLH01
-
Test Method:
-
Chromatography/Ion-exchange liquid chromatography
-
Testing Range:
-
3%-18%
-
Photometer:
-
415nm LED integral flow colorimeter
-
Testing Mode:
-
Auto test for batch, single test for emergency
-
Sample Type:
-
venous blood(EDTA anticoagulation)peripheral finger blood
-
Display:
-
LCD Display, showing real-time testing curve
-
Printer:
-
58mm Thermal Printer
-
Working Environment:
-
Temperature 15-30C, relative humidity<85%
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Brand Name:
-
BIOBASE
-
Model Number:
-
BK-GLH01
-
Place of Origin:
-
Shandong, China
-
Name:
-
Auto Glycated Hemoglobin HbA1c Analyzer
-
Model:
-
BK-GLH01
-
Test Method:
-
Chromatography/Ion-exchange liquid chromatography
-
Testing Range:
-
3%-18%
-
Photometer:
-
415nm LED integral flow colorimeter
-
Testing Mode:
-
Auto test for batch, single test for emergency
-
Sample Type:
-
venous blood(EDTA anticoagulation)peripheral finger blood
-
Display:
-
LCD Display, showing real-time testing curve
-
Printer:
-
58mm Thermal Printer
-
Working Environment:
-
Temperature 15-30C, relative humidity<85%
BIOBASE Portable Glycated Hemoglobin HbA1c Analyzer, BK-GLH01
More information, please send an inquiry, Cherry will reply to you soon, thanks.
Technical Parameters:
Model |
BK-GLH01 |
|
Basic Parameters |
Test Method |
Chromatography/Ion-exchange liquid chromatography |
Testing Item |
Glycated hemoglobin HbA1c |
|
Testing Range |
3%~18% |
|
Testing Parameter |
Precision(CV)≤3% |
|
Testing Time |
4 minutes(Including report) |
|
Sample Type |
Venous blood(EDTA anticoagulation) peripheral finger blood |
|
Function Parameters |
Photometer |
415nm LED Integral flow colorimeter |
Sampling Mode |
Full-auto 25 position sample turntable (20 sample positions, 2 quality control positions, 1 emergency position, 1 cleaning position, 1 zero position) |
|
Testing Mode |
Auto Test for batch, single test for emergency |
|
Calibration |
Optional 2 points or 4 points calibration, Manual or automatic, 2 sets of high and low level calibration |
|
Thermostatic Control |
Column and reagent thermostatic control 25±1℃ |
|
Reagent Matching |
One piece of column an reagent consumable/300 pieces of test samples |
|
Reagent Allocation |
Each standard package include A, B, C, D, eluent, Calibrator, Hemolytic agent, Pump tube |
|
Output Parameters |
Display |
LCD Display, showing real-time testing curve |
Printer |
58mm thermal printer |
|
Report Output |
IFCC concentration value, NGSP area percentage, ADAG average glucose |
|
Date Storage |
1000 test report(including testing curve) |
|
Communication Interface |
RS232, HIS/LIS System available |
|
Working Parameters |
Power Supply |
220V±10%, 50Hz |
Main Size(W*D*H) |
520*392*500mm |
|
Sampling System Size(W*D*H) |
265*215*255mm |
|
Main Weight |
14kg |
|
Sampling System Weight |
2kg |
|
Working Environment |
Temperature 15~30℃ Relative humidity≤85% |