- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
MeCan
-
Model Number:
-
MCS0024
-
Quality Certification:
-
None
-
Voltage:
-
220V±10V, 50Hz ±1Hz
-
Working frequency:
-
330KHz ~ 460KHz
-
Leakage currents to ground:
-
Less than 0.5mA
-
Leakage currents to patient:
-
Less than 0.01mA
-
Environmental temperature range:
-
5°C~ 40°C
-
Relative moisture range:
-
≤80%
-
Atmosphere pressure range:
-
86.0 ~ 106.0 Kpa
-
Max. power:
-
350W
-
power frequency:
-
60Hz±1Hz
-
Rating power:
-
880VA
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
MeCan
-
Model Number:
-
MCS0024
-
Quality Certification:
-
None
-
Voltage:
-
220V±10V, 50Hz ±1Hz
-
Working frequency:
-
330KHz ~ 460KHz
-
Leakage currents to ground:
-
Less than 0.5mA
-
Leakage currents to patient:
-
Less than 0.01mA
-
Environmental temperature range:
-
5°C~ 40°C
-
Relative moisture range:
-
≤80%
-
Atmosphere pressure range:
-
86.0 ~ 106.0 Kpa
-
Max. power:
-
350W
-
power frequency:
-
60Hz±1Hz
-
Rating power:
-
880VA
Surgical High Frequency Electrosurgical Unit, Portable Diathermy Machine
Model:
MCS0024
Introduction
Excellent compatibility, available in vessel sealing, suitable for general surgery,vascular surgery, hepatobiliary and pancreatic surgery, cardiothoracic surgery, gastroenterology, TURP and TUVP, and compatible with cystoscopy, arthroscopy, laparoscopy and hysteroscopy.
Features
What is the features of our bipolar electrosurgical unit?
1. Automatic Detection Function for Startup and Error Function.
2.Memory Function. Therer are totally 10 memory settings, the previous power setting digits is presented when restart the generator
3.Neutral electrode contact quality inspection system, the contact area between the pad and the patient skin can be detected,the system is providing the real-time evaluation of the pad and the patient skin to see if it is big enough for the efficient contact area, the output will be automatically stopped and alarm is raised once it's detected that the contact area is getting small to the certain dangerous situation.
4.Large vessel ligation
5. It can start the argon system, the set of argon plasma coagulation system is completed by matching up with the argon system.
6.Huge high-definition digital display.
7.With excellent compatibility, it connects with cystoscopy, arthroscopy, laparoscopy, and hysteroscopy and providing them the power source to cutting and coagulation. It also operated at the urethral resection of the prostate(TURP),the arthroscopic surgery and the usage of gasification electrode surgery(TUVP) etc.
8.Each output terminal is independent output design.
Parameter
Voltage
|
220V±10V, 50Hz ±1Hz
|
Working frequency
|
330KHz ~ 460KHz
|
Leakage currents to ground
|
Less than 0.5mA
|
Leakage currents to patient
|
Less than 0.01mA
|
Environmental temperature range
|
5°C~ 40°C
|
Relative moisture range
|
≤80%
|
More Detail
Details Images
What is the the standard configuration included?
Main unit
|
1 set
|
Electrosurgical Pencil
|
5 pcs
|
Electrosurgical Pad
|
10 pcs
|
Electrosurgical pad cable
|
1 pc
|
Footswitch
|
1 set
|
Bipolar Forceps
|
1 pc
|
Bipolar forceps cable
|
1 pc
|
Accessories of the electrosurgical cautery unit
Recommend Products
Hot Searches