- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
HIRP
-
Model Number:
-
RP6-63S
-
Rated Current:
-
63A
-
Product name:
-
Automatic Transfer Switch
-
Certificate:
-
CE,CB
-
Standard Control voltage:
-
220V
-
Frequency:
-
50/60Hz
-
Pole:
-
4 Poles
-
Function:
-
Transferring between normal power and reserve power
-
Warranty:
-
24 Months
-
Whether the smart:
-
No
-
Max. Voltage:
-
400V
Quick Details
-
Type:
-
CB
-
Number of Pole:
-
4
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
HIRP
-
Model Number:
-
RP6-63S
-
Rated Current:
-
63A
-
Product name:
-
Automatic Transfer Switch
-
Certificate:
-
CE,CB
-
Standard Control voltage:
-
220V
-
Frequency:
-
50/60Hz
-
Pole:
-
4 Poles
-
Function:
-
Transferring between normal power and reserve power
-
Warranty:
-
24 Months
-
Whether the smart:
-
No
-
Max. Voltage:
-
400V
Products Description
RP6-63S is terminal type ATS. It’s suitable for 3 phases 4 wires (or 1 phase 1 wire) dual power grid with AC 50/60Hz, rated voltage 400V/230V and rated current up to 63A. When one power goes wrong (only test normal Phase A voltage and reserve Phase A voltage, only test loss voltage or loss phase), it will automatically connect one or several load circuits from one power to the other power, to ensure normal power supply of load circuits. The ATS conforms to IEC60947-6-1 and GB/T14048.11
Normal conditions for operation and installation:
Environmental Temperature Condition:-5~+40°C
Installation site is not more than 2000 meters above sea level.
Pollution Level: Grade 3
Installation Category: 3
Vertical installation or horizontal installation
Normal conditions for operation and installation:
Environmental Temperature Condition:-5~+40°C
Installation site is not more than 2000 meters above sea level.
Pollution Level: Grade 3
Installation Category: 3
Vertical installation or horizontal installation
Product Paramenters
Rated Current Ie A
|
6,10,16,20,25,32,40
|
50,63
|
|
|
|||
Electrical Appliances Class
|
CB
|
|
|
|
|||
Use Category
|
AC~33iB
|
|
|
|
|||
Tripping Current
|
5~10In(Type C)
|
10~15In(Type D)
|
|
|
|||
Rated Voltage Ue
|
220V(2P), 400V(3P, 4P)
|
|
|
|
|||
Rated Frequency
|
50Hz/60Hz
|
|
|
|
|||
Rated Short Circuit Connection Ability Icm (Peak)
|
7.65KA
|
|
|
|
|||
Rated Short Circuit Breaking Ability Icm (Effective Value)
|
5KA
|
|
|
|
Specification
Appearance & Installation Dimension
ATS can be installed in power control cabinet directly. Users can wire after ATS installation (refer to design and use). As per current value use suitable conductor to connect the mains side (top terminal) and load side (bottom terminal) of MCB of normal electric power and standby electric power. In-phase parallel connection at load side, and ensure the phase sequence of normal electric power and standby electric power must be accordant (Wire as per A,B,C,N sequence). For 3 poles ATS should add one conductor with section not less than 0.3mm2 to connect theneuter line of power supply correctly, thus ATS can work properly. For 4 poles or 2 poles ATS, N pole of normal electric power and standby electric power should be connected to N pole of MCB respectively. In addition, when install ATS please ground reliably at grounding mark.
Auxiliary terminal is active contact signal, only used for external connection with indicator to display Off state, should be connected to the indicator directly. Can’t put in power at auxiliary terminal (but for 3 poles ATS should add one conductor with section not less than 0.3mm2 to connect theneuter line of power supply and the terminals of neuter line on ATS auxiliary terminal.Otherwise ATS can’t work properly.)
Auxiliary terminal is active contact signal, only used for external connection with indicator to display Off state, should be connected to the indicator directly. Can’t put in power at auxiliary terminal (but for 3 poles ATS should add one conductor with section not less than 0.3mm2 to connect theneuter line of power supply and the terminals of neuter line on ATS auxiliary terminal.Otherwise ATS can’t work properly.)
Use
1) Normal use, please set the switch of controller at Automatic Function. Under Auto working the controller of ATS monitor normal electric power and standby electric power and display running status of ATS. When Normal power cut, novoltage, failure, ATS will transfer load automatically from normal power to standby power. If normal power get right, ATS will transfer load automatically from standby power to normal power. The luminous diode on switch panel indicate switch off situation.
2) If you don’t adopt automatic transfer or need other manual operation please set the controller at manual. Under manual operation the controller stop work, and manual operation can make the breaker on off, and the switch doesn’t transfer automatically.
3) When ATS is short circuit or over load, The MCB of ATS will protect tripping. If power display normally the handle of MCB is switching on. If the MCB has protected tripping users should set at manual and operate the switch to dual separating brake by hand, and check the reason of trip. After trouble clearing please set the controller at auto again to operate.
4) When ATS transfer to auto from manual, if normal and standby power are normal ATS will prior connect normal power to load (even if load connected standby power ago)
Matters need attention
When users test or operate please follow relative rules and pay attention to the following matters to ensure use our ATS correctly.
1)Neutral conductor N can’t be connected in wrong way, must connect reliably, otherwise ATS can’t operate properly, even burn controller and motor.
2)The protective grounding of ATS must be connected reliably to ensure safety.
3)Detection sampling signal for controller work power and main power supply is taken from Power supply side of main circuit, and work power of auxiliary connection terminal used for connect indicator is taken from main circuit, so can’t have voltage test between spare terminals (unless dismantle the secondary wires). Can have power frequency voltage test between main circuit and shell or between secondary auxiliary terminals and shell.
Simple troubleshooting
When users find fault can request professional to test and deal with. Keep Away for Safety when operate. Or contact our Specialized Service Departments.
1) Double Power are both switched on, but ATS can’t transfer automatically
1. Check Auto/manual should be in automatic position.
1) Normal use, please set the switch of controller at Automatic Function. Under Auto working the controller of ATS monitor normal electric power and standby electric power and display running status of ATS. When Normal power cut, novoltage, failure, ATS will transfer load automatically from normal power to standby power. If normal power get right, ATS will transfer load automatically from standby power to normal power. The luminous diode on switch panel indicate switch off situation.
2) If you don’t adopt automatic transfer or need other manual operation please set the controller at manual. Under manual operation the controller stop work, and manual operation can make the breaker on off, and the switch doesn’t transfer automatically.
3) When ATS is short circuit or over load, The MCB of ATS will protect tripping. If power display normally the handle of MCB is switching on. If the MCB has protected tripping users should set at manual and operate the switch to dual separating brake by hand, and check the reason of trip. After trouble clearing please set the controller at auto again to operate.
4) When ATS transfer to auto from manual, if normal and standby power are normal ATS will prior connect normal power to load (even if load connected standby power ago)
Matters need attention
When users test or operate please follow relative rules and pay attention to the following matters to ensure use our ATS correctly.
1)Neutral conductor N can’t be connected in wrong way, must connect reliably, otherwise ATS can’t operate properly, even burn controller and motor.
2)The protective grounding of ATS must be connected reliably to ensure safety.
3)Detection sampling signal for controller work power and main power supply is taken from Power supply side of main circuit, and work power of auxiliary connection terminal used for connect indicator is taken from main circuit, so can’t have voltage test between spare terminals (unless dismantle the secondary wires). Can have power frequency voltage test between main circuit and shell or between secondary auxiliary terminals and shell.
Simple troubleshooting
When users find fault can request professional to test and deal with. Keep Away for Safety when operate. Or contact our Specialized Service Departments.
1) Double Power are both switched on, but ATS can’t transfer automatically
1. Check Auto/manual should be in automatic position.
2. Check if incoming line is correct or not, if phase sequence is accordance or not, and wiring is solid and reliable or not.
3. Check if the fuse is burned on not.
2) Double power are both switched on, ATS standby power is switching on.
1. Check if normal power incoming line has voltage or not.
2. Check Commonly used insurance
3. Check if external light is connected in wrong way or not.
3. Check if the fuse is burned on not.
2) Double power are both switched on, ATS standby power is switching on.
1. Check if normal power incoming line has voltage or not.
2. Check Commonly used insurance
3. Check if external light is connected in wrong way or not.
Product packaging
Certifications
FAQ
1,Q:Why your quotation is higher than some other suppliers?
A:In domestic market, the high and low quality brands are mixed together. There are many low-cost ATS which is actually assembled with some cheaper and unstable parts, it crudely, to reduce costs and use of substandard components for assembly, there is a very big security risk! In order to protect the pro personal and property safety, please do not covet low price, be sure to choose a reliable ATS!
..............................................................................................................................................................
2,Q:Your ATS control voltage is 220V or 110V ?
A:Our ATS control voltage is normally 220V(240V),50Hz,if your Control voltage is 110V(120V) 60Hz,then you must tell us about this,it is important for us to make correct ATS for you.
..............................................................................................................................................................
3,Q:Should I choose 2Poles,3Poles or 4Poles ATS?
A:If your two power supply are single phase(L-N),then you can choose 2Poles or 4Poles ATS.
If your two power supply are three phases three wires(L-L-L),then you can choose 3Poles ATS.
If your two power supply are three phases four wires(L-L-L-N),then you can choose 4Poles ATS.
..............................................................................................................................................................
4,Q:In our country,voltage is very unstable,Your ATS will be easy to be damaged?
A: As we said we use the best quality key parts for ATS,such as Relays in ATS,We use silver contact relays which is famous chinese brand.
A:In domestic market, the high and low quality brands are mixed together. There are many low-cost ATS which is actually assembled with some cheaper and unstable parts, it crudely, to reduce costs and use of substandard components for assembly, there is a very big security risk! In order to protect the pro personal and property safety, please do not covet low price, be sure to choose a reliable ATS!
..............................................................................................................................................................
2,Q:Your ATS control voltage is 220V or 110V ?
A:Our ATS control voltage is normally 220V(240V),50Hz,if your Control voltage is 110V(120V) 60Hz,then you must tell us about this,it is important for us to make correct ATS for you.
..............................................................................................................................................................
3,Q:Should I choose 2Poles,3Poles or 4Poles ATS?
A:If your two power supply are single phase(L-N),then you can choose 2Poles or 4Poles ATS.
If your two power supply are three phases three wires(L-L-L),then you can choose 3Poles ATS.
If your two power supply are three phases four wires(L-L-L-N),then you can choose 4Poles ATS.
..............................................................................................................................................................
4,Q:In our country,voltage is very unstable,Your ATS will be easy to be damaged?
A: As we said we use the best quality key parts for ATS,such as Relays in ATS,We use silver contact relays which is famous chinese brand.
For motor in the ATS,we use copper coil quality. So all of these will assure our ATS quality better and stable than some other suppliers.
..............................................................................................................................................................
5,Q:How many years quality warranty you can offer?
A:We promise to give customer 2 years warranty since we ship the goods,our warranty time is longer than most of competitors.
..............................................................................................................................................................
6,Q: Can I get some samples?
A: Yes,sample order is available for quality check and market test.
..............................................................................................................................................................
7,Q: What’s the delivery time?
A: It usually takes about 2-5 working days for small sample order and 10-35 days for big order.
..............................................................................................................................................................
5,Q:How many years quality warranty you can offer?
A:We promise to give customer 2 years warranty since we ship the goods,our warranty time is longer than most of competitors.
..............................................................................................................................................................
6,Q: Can I get some samples?
A: Yes,sample order is available for quality check and market test.
..............................................................................................................................................................
7,Q: What’s the delivery time?
A: It usually takes about 2-5 working days for small sample order and 10-35 days for big order.
Hot Searches