- Product Details
- {{item.text}}
Quick Details
-
Weight:
-
150 KG
-
Power:
-
4300
-
Product name:
-
Water Cooled Water Chiller
-
Application:
-
Industrial Cooling Solutions
-
Function:
-
Circulating Cooling Water
-
Cooling type:
-
Water Cooled Condenser
-
Refrigerant:
-
R-22/R134a
-
Compressor type:
-
Totally closed vortex type or piston type
-
Refrigeranting capacity:
-
13690-16018Kcal/h
-
Pump power:
-
0.55kw
-
Water Tank Capacity:
-
0.045m³
-
Range of temperature control:
-
3°CNormel temperature( Over 0°Ccan be customized)
Quick Details
-
Condition:
-
New
-
Place of Origin:
-
Guangdong, China
-
Dimension(L*W*H):
-
1050*500*1000m
-
Weight:
-
150 KG
-
Power:
-
4300
-
Product name:
-
Water Cooled Water Chiller
-
Application:
-
Industrial Cooling Solutions
-
Function:
-
Circulating Cooling Water
-
Cooling type:
-
Water Cooled Condenser
-
Refrigerant:
-
R-22/R134a
-
Compressor type:
-
Totally closed vortex type or piston type
-
Refrigeranting capacity:
-
13690-16018Kcal/h
-
Pump power:
-
0.55kw
-
Water Tank Capacity:
-
0.045m³
-
Range of temperature control:
-
3°CNormel temperature( Over 0°Ccan be customized)
They feature excellent performance and a long lifespan. The series of working flow is based on the basic principle of heat exchange. It is applicable to the industry that requires flow of precisely controlled chilled water, and considered as indispensable equipment for modern industry.
After starting up, the compressor ① starts to work, the refrigerant becomes into high pressure and high temperature gas under the
compression effect of the compressor and circulates towards the direction of A-B; in the process of B-C-A the high pressure and
high temperature gas of refrigerant passes through the condenser ②, changes the energy of heat with the cooling water, and
transforms into liquid state from gaseous state, at the same time, the cooling water makes away with the energy of heat; in the
process of D-E, the refrigerant of liquid state passes through the thermostatic expansion valve ④, the pressure reduces, partial
refrigerant transforms into gaseous state from liquid state, at this time the refrigerant is in the state of two phases admixture
of liquid state and gaseous state, in the process of E-A, the refrigerant passes through the evaporator ⑤, changes the energy of
heat with transferring medium in the evaporator, cools down the refrigerated water to achieve the required temperature to meet the
requirements; the refrigerant in gaseous state after passing through the evaporator returns to compressor, then one time for
refrigerating cycle is completed.
compression effect of the compressor and circulates towards the direction of A-B; in the process of B-C-A the high pressure and
high temperature gas of refrigerant passes through the condenser ②, changes the energy of heat with the cooling water, and
transforms into liquid state from gaseous state, at the same time, the cooling water makes away with the energy of heat; in the
process of D-E, the refrigerant of liquid state passes through the thermostatic expansion valve ④, the pressure reduces, partial
refrigerant transforms into gaseous state from liquid state, at this time the refrigerant is in the state of two phases admixture
of liquid state and gaseous state, in the process of E-A, the refrigerant passes through the evaporator ⑤, changes the energy of
heat with transferring medium in the evaporator, cools down the refrigerated water to achieve the required temperature to meet the
requirements; the refrigerant in gaseous state after passing through the evaporator returns to compressor, then one time for
refrigerating cycle is completed.
S
chematic Drawing of Installation
Feature
1>
Adopting imported compressor heads from Europe and America
2>
Copper pipes are welded using anaerobic welding method
3>
RS485 communication function, achieving automated management (optional)
4>
Adopting imported advanced components, with a long service life
5>
Electrical appliances adopt
OMRON.FUJI,TE.LG,MOELLER,ABB,WEST
6>
Control method: Imported microcomputer or PLC control (optional)
7>
Complete safety protection, fault display, no need for professional personnel for maintenance and repair
8>
Efficient evaporators and condensers can save over 30% of energy
9>
Two sets of compressor heads are used for 20P and above, which can be used separately or together
Low Noise Condenser Fan
Circulating Water Pump
Pressure Gauge
Control Panel
Filte
r
Electrical Cabinet
Water Pump
PLC Control Panel
Fan
Large elevation angle, large air volume, low speed quiet external rotation axial fan.
Pressure Gauge
Installation of high and low-pressure gauges to monitor the pressure of the water pump during operation at any time.
2000m
2
Self-Own Factory
99%
of Progresses of Self-Control
2009
14
Years of
20
+ Personnel
150
+ Personnel
Founded R&D Manufacturing
R&D Team Workshop
Team
20000
m
2
30
+Patents
98
Self-Own Factory Patents Countries&Regions
More Than
30 Patents
in Inventions & Utility Designs
Exhibition
Hot Searches