Products
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China
Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China

Intelligent Oil Lpg Gas Saturated Steam Vortex Sensor Flow Meter Transmitters From China

FOB Reference Price: Get Latest Price
≥1 Sets
US $180
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
CS-SUP
Measuring medium:
Water, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Wafer connection:
DN10-DN500(priority PN2.5MPa)
Flange connection:
DN10-DN500
HS Code:
90261000
Measuring Principle:
Electrical Principles
Measurement Object:
Closed Pipeline
Medium Temperature:
-40℃~+260℃,-40℃~+300℃
Output signal:
4-20mA or frequency
Interface:
RS485,HART
Ingress protection:
IP65(IP67, IP68 need to customize)

Quick Details

Type:
Variable Area Water Flowmeters, Variable Area Air & Gas Flowmeters, Variable Area Petrolum Flowmeters, Variable Area Oil Flowmeters
Warranty:
1 year
Place of Origin:
Jiangsu, China
Model Number:
CS-SUP
Measuring medium:
Water, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
Wafer connection:
DN10-DN500(priority PN2.5MPa)
Flange connection:
DN10-DN500
HS Code:
90261000
Measuring Principle:
Electrical Principles
Measurement Object:
Closed Pipeline
Medium Temperature:
-40℃~+260℃,-40℃~+300℃
Output signal:
4-20mA or frequency
Interface:
RS485,HART
Ingress protection:
IP65(IP67, IP68 need to customize)

Explosion-proof Flow Meter Dn50 316 Stainless

Steel Saturated Steam Vortex Flowmeter Sensor

Flange Connection

High precision with good price
PRODUCT SPECIFICATIONS
TYPE 2
Vortex flow meters
Vortex flow meters are designed for measuring the volume/mass flow of liquids, gases and steam based on Karman vortex principle.
Main Features:
1. Configure with temperature/pressure senor.
2. Low power consumption, a dry battery can service at least 3 years.
3. Self-checking function: the rich self-checking information makes maintenance and debugging easy.
4. Three-Wire system supports RS485 communication.
Product Paramenters
Vortex flow meters
DN (mm)
DN25-DN300, DN300~1000 insert type
PN
1.6MPa ~4.0MPa
Range ratio
1:6~1:30
Power
+24V DC; 3.6V battery
Fluid
Steam, Gas, Liquid
Material
Carbon steel, SS304, SS316
Accuracy
±1.5%R, ±1FS; insert: ±2.5%R, ±2.5%FS
Signal
pulse (no-battery) or 4~20mA
Suitable temp.
-40~250 ºC, -40~450C
IP
IP65 or IP68 on order
Vibrating acceleration
Piezoelectric type:0.2g, Capacitance:1.0~2.0g
Transmission distance
3-wire flow sensor:≤300m, 2-wire 4~20mA: load resistance≤750Ω
Environment
Temp -20ºC~55ºC,Relative humidity 5%~90%, Atm press 86~106kPa
Electromagnetic Flow Meter
Main power
AC220V 50HZ/110VAC / DC24V /battery/solar
Display
LCD display with back lighting can display the instantaneous flow ,total flow and percentage of flow as well as alarm display
Connection method
clamp on,wafer,flange(JIS,DIN,ANSI,ASME,),thread(BSP,NPT,G,CG),tri clamp,clamping ,welding
Body material
SS304,SS316L,CS,PP
Lining material
PTFE,NBR,rubber,F46,F4,EPDM,PO,PPS,PEA,ceramics
electrode
SS316L,HC,HB,Ti,Ta,Pt,ceramics
Accuracy
±0.5% of the value displayed ,±0.3% or ±0.2% are selectable.
Signal output
4-20ma,pulse,0-5V,0-10V,Alarm
Communication
RS232 ,RS485,Profibus or HART Communication are selectable ,
Protection class
IP65/IP68(split type)
Ex-proof Mark
Exd IIBT4
Accumulator
Forward total quantity ,reverse total quantity
Medium Temperature
-40ºC ~ +180ºC
Medium Electrical Conductivity
≥ 20μs/cm;special make ≥ 5μs/cm
Measuring Range
1500 : 1, flow rate < 15m/s
Liquid Turbine flowmeter
Nominal diameter
4~200mm
Accuracy level
±1%R. ±0.5%R. ±0.2%R(Need to be specially made)
flow velocity range
0.9-7m/s
Work temperature
-20 C~+110 C
Work pressure
1.6Mpa;2.5Mpa;4Mpa;6.3Mpa;>6.3Mpa~20MPa
Ambient
Temp.: -10 C to +55 C, Pressure: 86 to 106 KPa , Humidity: 5% to 90%
Material
304SS ; SS316L etc
Output mode
Field display ; 4-20ma ; pulse signal
Communications
RS485, HART
Explosion-proof
Explosion-proof EXdII BT1~T6;Intrinsic explosion-proof type EXiaII CT1~T6
Protection level
IP65 (Can customizable higher)
Gas turbine flowmeter
Measuring diameter
25~300mm
Accuracy level
±1.5%R, ±1%R
Flow rate range
2.2-80m/s
Medium temperature
-30oC~+80oC
Working pressure
1.6Mpa; 2.5Mpa; 4Mpa
Environmental temp.
-20oC~+60oC
Material
304SS ; SS316L
Power supply
8-24VDC+ 3.6V lithium battery
Output mode
Field display; 4-20mA; pulse
Communication
RS485 ; HART
Explosion-proof
EXdII BT1 ~ T6 , EXiaII CT1 ~ T6
Protection level
IP65 ( or higher )
Coriolis Mass flow meter
Diameter
10~150mm
Accuracy
0.5%; 0.2%; 0.15%; 0.1%
Repeatability
±0.1~0.25%
Density measurement range
0.5~3.000g/cm3, Accuracy: ±0.002 g/cm3
Temperature measuring range
-200~350ºC, Accuracy: ±1ºC
Material
The measuring tube SS316L; Housing: SS304
Working pressure
0~4.0MPa
Ambient temperature
-40ºC~60ºC
Power supply
18~36VDC;85~265VAC
Unit
Mass flow rate: g/h. kg/h. t/h. g/m. kg/m. t/m
Total flow: g, kg, t
Volume flow rate: cm³/h. dm³/h. m³/h. cm³/m. dm³/m. m³/m
Total volume: cm³/m. dm³/m
Density: kg/m³. g/cm³
Temperature:ºC. K. ºF
Output signal
0~10000Hz pulse frequency signal flow signal (open collector signal)
Equivalent pulse signal flow signal
4~20mA Current signal choose one signal from flow rate, density, temperature
Current output load capacity is not less than 750Ω(24VDC power supply)
Accuracy: Pulse signal 0.05%
Current signal 0.2%
Communication signal: RS485, MODBUS protocol
Hart
Explosion-proof level
Exd (ia) II C T6Gb
Transmitter and Sensor protection
IP67
Ultrasonic flowmeter
Items
Specifications




Main unit
Accuracy
Better than ±1%
Repeatability
Better than 0.2%
Display
LCD with backlight, display accumulated flow/heat, instantaneous flow/heat, velocity, time etc.



Output
Analogue output: 4-20mA or 0-20mA current output. Impedance 0∼1kW. Accuracy 0.1%.
OCT output: Frequency signal (1~9999HZ)
Relay output: over 20 source signal (no signal, reverse flow etc.)
RS485 serial port


pipe
material
Steel, stainless steel, cast iron, cement pipe, copper, PVC, aluminum, FRP etc. Liner is allowed
Size
15-6000mm
Straight pipe section
In the upstream it must be beyond 10D, in the downstream it must be beyond 5D, in the upstream the length must be beyond 30D fro
the access of the pump. (D stands for pipe diameter)


Liquid

Types
Water, sea water, industrial sewage, acid & alkali liquid, alcohol, beer, all kinds of oils which can transmit ultrasonic single
uniform liquid
Temperature
Standard: -30˚C - 90˚C ,High-temperature:-30˚C - 160˚C
Turbidity
Less than 10000ppm, with a little bubble
Flow Direction
Bi-directional measuring, net flow/heat measuring

Cable
Twisted Pair Line, standard length of 20m, can be extended to 500m (no recommended); Contact the manufacturer for longer cable
requirement.
RS-485 interface, transmission distance up to 1000m
Power Supply
AC220V or DC24V
Power Consumption
Less than 1.5W
Protocols
MODBUS, M-BUS, Fuji extended protocol and other factory protocol
Thermal gas mass flowmeter
Measuring Medium
Various gases (Except the acetylene)
Pipe Size
DN10~DN4000mm
Velocity
0.1~100 Nm/s
Accuracy
±1~2.5%
Working
Temperature
Sensor: -40ºC~+550ºC
Transmitter: -20ºC~+45ºC
Working Pressure
Insertion Sensor: medium pressure≤ 1.6MPa
Flanged Sensor: medium pressure≤ 1.6MPa Special pressure please contact us
Power Supply
Compact type: 24VDC or 220VAC, Power consumption ≤18W
Remote type: 220VAC, Power consumption ≤19W
Output
4-20mA (optoelectronic isolation, maximum load 500Ω), Pulse,
RS485 (optoelectronic isolation) and HART
Alarm Output
1-2 line Relay, Normally Open state, 10A/220V/AC or 5A/30V/DC
Sensor Type
Standard Insertion, Hot-tapped Insertion and Flanged
Construction
Compact and Remote
Pipe Material
Carbon steel, stainless steel, plastic, etc
Display
4 lines LCD
Mass flow, Volume flow in standard condition, Flow totalizer, Date and Time, Working time, and Velocity, etc.
Protection Class
IP65
Sensor Housing
Material
Stainless steel (316)
Applicable media
Dry gas, air which doesn't contains water.
Measuring range
0.05-141m/s (at standard conditions 20ºC, 0.101325MPa), if flow velocity out of
this range, please consult with the manufacturers customization
Our Advantages
1. Integrating R&D, production, distributing and technical services
2.After Warranty Service
Site Installation and commissioning, 24 hours online support and Video technical support
SIMILAR PRODUCTS
DCS & SIS CONTROL SYSTEM SUPPLY

APP
Post My RFQ
WhatsApp
+86-17326049340