- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
JSCS
-
Model Number:
-
JSCS009
-
Principle:
-
Radar Pulse
-
Range:
-
10-150m
-
Accuracy:
-
0.1%/0.15%/0.2%/0.25%
-
Kind:
-
Radar Level Transmitter
-
Material:
-
Aluminium Alloy Housing
-
Certification:
-
CE, Exiaii CT6 Ga, Exd Ia II CT6 GB/ IP67
-
Application:
-
Hygienic liquid storage, Corrosive
-
Process Temperature:
-
-40~130℃
-
Process Pressure:
-
-0.1~4.0 MPa
-
Process Connection:
-
Flange Connection
Quick Details
-
Grade:
-
Industrial
-
Warranty:
-
3 years
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
JSCS
-
Model Number:
-
JSCS009
-
Principle:
-
Radar Pulse
-
Range:
-
10-150m
-
Accuracy:
-
0.1%/0.15%/0.2%/0.25%
-
Kind:
-
Radar Level Transmitter
-
Material:
-
Aluminium Alloy Housing
-
Certification:
-
CE, Exiaii CT6 Ga, Exd Ia II CT6 GB/ IP67
-
Application:
-
Hygienic liquid storage, Corrosive
-
Process Temperature:
-
-40~130℃
-
Process Pressure:
-
-0.1~4.0 MPa
-
Process Connection:
-
Flange Connection
Product Description
80 Ghz/120Ghz high frequency Radar Level Meter Level
Measuring Tool Tank Liquid Water Monitoring Measurement
Device Cement Silo Sensor Transmitter/level measurement
* Radar level measurement *
W- Band 76-80GHz Radar level meter uses the millimeter wave band with a higher frequency than the Ku-band radar. It has important applications in long-distance target detection, strong smoke and dust environments, long-distance imaging, multi-spectral imaging,etc.And it can detect smaller targets and achieve more precise positioning than microwave radar, with higher resolution and stronger secrecy.
W- Band 76-80GHz Radar level meter uses the millimeter wave band with a higher frequency than the Ku-band radar. It has important applications in long-distance target detection, strong smoke and dust environments, long-distance imaging, multi-spectral imaging,etc.And it can detect smaller targets and achieve more precise positioning than microwave radar, with higher resolution and stronger secrecy.



Measuring Range
|
30m
|
Accuracy
|
±1mm
|
Working Frequency
|
W-band, 76~81GHz
|
Process connection
|
Flange
|
Beam angle
|
<3°
|
The antenna material
|
PTFE, PFA
|
Process Temperature
|
(-40~80) ℃(standard type)
|
Process Pressure
|
(0~1) Mpa
|
Signal output
|
4-20mA/HART (2-wire/4-wire)
RS485/Modbus |
Power Source
|
Two-wire (DC24V)
Four-wire(DC24V/AC220V) |
Current Consumption
|
90mW
|
Connection
|
Thread, Flange
|
Protection Grade
|
IP67
|
Explosion-proof Grade
|
Exia IIC T6 Ga/Exd IIC T6 Gb
|

Measuring Range
|
0.045m~120m
|
Accuracy
|
±1mm
|
Working Frequency
|
W-band, 76~81GHz
|
Process connection
|
Flange
|
Beam angle
|
<3°
|
The antenna material
|
PTFE, PFA
|
Process Temperature
|
(-40~80) ℃(standard type)
|
Process Pressure
|
(0.1~2) Mpa
|
Signal output
|
4-20mA/HART (2-wire/4-wire)
RS485/Modbus |
Power Source
|
Two-wire (DC24V)
Four-wire(DC24V/AC220V) |
Current Consumption
|
90mW
|
Connection
|
Thread, Flange
|
Protection Grade
|
IP67
|
Explosion-proof Grade
|
Exia IIC T6 Ga/Exd IIC T6 Gb
|
Measuring Range
|
150m
|
Accuracy
|
±1mm
|
Working Frequency
|
W-band, 76~81GHz
|
Process connection
|
Flange
|
Beam angle
|
<3°
|
The antenna material
|
PTFE, PFA
|
Process Temperature
|
(-40~80) ℃(standard type)
|
Process Pressure
|
(0~1) Mpa
|
Signal output
|
4-20mA/HART (2-wire/4-wire)
RS485/Modbus |
Power Source
|
Two-wire (DC24V)
Four-wire(DC24V/AC220V) |
Current Consumption
|
90mW
|
Connection
|
Thread, Flange
|
Protection Grade
|
IP67
|
Explosion-proof Grade
|
Exia IIC T6 Ga/Exd IIC T6 Gb
|
Suitable for Medium
|
All kind of corrosive liquid
|
Measuring Range
|
10m
|
Frequency
|
26GHz
|
Accuracy
|
±5mm
|
Process Temperature
|
(-40~130) ℃
|
Process Pressure
|
(-0.1~0.3) Mpa
|
Signal output
|
4-20mA/HART (2-wire/4-wire)
RS485/ Modbus |
Power Source
|
Two-wire (DC24V)
Four-wire(DC24V/AC220V) |
Connection
|
Thread, Flange
|
Protection Grade
|
IP67
|
Explosion-proof Grade
|
Exia IIC T6 Ga/Exd IIC T6 Gb
|
Measuring Range
|
0.02~60m
|
Accuracy
|
±1mm
|
Working Frequency
|
W-band, 76~81GHz
|
Process connection
|
Flange
|
Beam angle
|
<3°
|
The antenna material
|
PTFE, PFA
|
Process Temperature
|
(-40~80) ℃(standard type)
|
Process Pressure
|
(-0.1~2) Mpa
|
Signal output
|
4-20mA/HART (2-wire/4-wire)
RS485/Modbus |
Power Source
|
Two-wire (DC24V)
Four-wire(DC24V/AC220V) |
Current Consumption
|
90mW
|
Connection
|
Thread, Flange
|
Protection Grade
|
IP67
|
Explosion-proof Grade
|
Exia IIC T6 Ga/Exd IIC T6 Gb
|
Measuring Range
|
0.02~30m
|
Accuracy
|
±1mm
|
Working Frequency
|
W-band, 76~81GHz
|
Beam angle
|
<7°
|
The antenna material
|
PTFE, PFA
|
Process Temperature
|
(-40~80) ℃(standard type)
|
Process Pressure
|
(-0.1~2) Mpa
|
Signal output
|
4-20mA/HART (2-wire/4-wire)
RS485/Modbus |
Power Source
|
Two-wire (DC24V)
Four-wire(DC24V/AC220V) |
Current Consumption
|
70mW
|
Connection
|
Thread, Flange
|
Protection Grade
|
IP67
|
Explosion-proof Grade
|
Exia IIC T6 Ga/Exd IIC T6 Gb
|
Main Types
Recommend Products
DCS & SIS CONTROL SYSTEM SUPPLY
Our Advantages
1. Integrating R&D, production, distributing and technical services
2. After Warranty Service
Site Installation and commissioning,
24 hours online support and Video technical support
Hot Searches