4 stage (5μ PP filter + Compressed activated carbon filter + 1μ PP filter + RO)
- Product Details
- {{item.text}}
Quick Details
-
Weight:
-
180kg
-
Size:
-
LxWxH=1.3x0.65x1.5m
-
Power:
-
1.1-1.8kw
-
Productivity:
-
250-1000L/hour
-
Weight (KG):
-
180 kg
-
Input water:
-
Tap water or equivalent bore water
-
Output water:
-
Direct drinking water, Pure water, Bottled water
-
Capacity available:
-
250L,500L,750L,1000L/hour
-
Function:
-
Water desalination/ Pure water making
-
Working theory:
-
RO (reverse osmosis) water desalination
-
Treatment procedure:
-
5μ PP fitler+Active carbon filter+1μ PP filter+RO
-
Optional:
-
Sand filter, Carbon filter, Chemical dosing, UV sterilizer
-
Operation:
-
Automatic (manual as optional)
-
OEM/ODM:
-
Available
Quick Details
-
Place of Origin:
-
Shaanxi, China
-
Brand Name:
-
APS
-
Material:
-
Plywood case, FRP / Carbon steel / SS304
-
Weight:
-
180kg
-
Size:
-
LxWxH=1.3x0.65x1.5m
-
Power:
-
1.1-1.8kw
-
Productivity:
-
250-1000L/hour
-
Weight (KG):
-
180 kg
-
Input water:
-
Tap water or equivalent bore water
-
Output water:
-
Direct drinking water, Pure water, Bottled water
-
Capacity available:
-
250L,500L,750L,1000L/hour
-
Function:
-
Water desalination/ Pure water making
-
Working theory:
-
RO (reverse osmosis) water desalination
-
Treatment procedure:
-
5μ PP fitler+Active carbon filter+1μ PP filter+RO
-
Optional:
-
Sand filter, Carbon filter, Chemical dosing, UV sterilizer
-
Operation:
-
Automatic (manual as optional)
-
OEM/ODM:
-
Available
Product Overview
RO Reverse osmosis well water filter system Water filter machine for commercial drinking water filter system
RO (reverse osmosis) is most advanced, effective, and energy-saving membrane separation technology nowadays.
Effectively remove the dissolving salt , ion, colloid, microorganism, heat source, organics, as well as other impurities such as bacteria, sugars, proteins, dyes and constituents having a molecular weight greater than 150-250 dalton.
It’s wildly used in Public use water treatment . Household, business group and other industry use. Treated water can reach tap water standard, WHO drinking water standard.
Effectively remove the dissolving salt , ion, colloid, microorganism, heat source, organics, as well as other impurities such as bacteria, sugars, proteins, dyes and constituents having a molecular weight greater than 150-250 dalton.
It’s wildly used in Public use water treatment . Household, business group and other industry use. Treated water can reach tap water standard, WHO drinking water standard.
Product Paramenters
Capaity (Liter/hour)
|
Capaity (Gallon/day)
|
Power
|
Recovery rate
|
Desalination rate
|
Input water
|
Output
|
Treatment procedure
|
||||||
100LPH
|
600GPD
|
1kw
|
35-50%
|
≥97%
|
Tap water or equivalent bore water
|
Direct drinking water
|
4 stage (5μ PP filter + Active carbon filter+1μ PP filter+RO)
|
||||||
250LPH
|
1500GPD
|
1.1kw
|
35-50%
|
≥97%
|
Tap water or equivalent
bore water
|
Direct drinking water
|
4 stage (5μ PP filter + Active carbon filter+1μ PP filter+RO)
|
||||||
500LPH
|
3000GPD
|
1.5kw
|
|
|
|
|
|
||||||
750LPH
|
4500GPD
|
1.5kw
|
|
|
|
|
|
||||||
1000LPH
|
6000GPD
|
1.8kw
|
|
|
|
|
|
||||||
Optional:
|
Sand filter, Active carbon filter, Water softener, UF ultra filter, EDI ultra pure water making, Pressure tank, UV sterilizer, Anti-scale dosing system, etc
|
|
|
|
|
|
|
||||||
Note:
|
We supply design service base on your water condition / analysis.
Capacity from 100L/hour to 1000m³/hour.
|
|
|
|
|
|
|
Operating conditions
|
Input pressure
|
Working pressure
|
Environment temperature
|
Input water temperature
|
|
0.2-0.4Mpa
|
0.8-1Mpa
|
5-45℃
|
5-35℃
|
Treatment Process
4 stage
(5μ PP filter + Compressed activated carbon filter + 1μ PP filter + RO)
Optional:
Sand filter, Active carbon filter, Water softener,
UF ultra filter, EDI ultra pure water making,
Pressure tank, UV sterilizer, Anti-scale dosing system, etc
Products Structure
Standard RO
Standard RO + Sand filter + Active carbon filter
5 stage (Sand filter + Carbon filter + 5μ PP filter + 1μ PP filter + RO)
Standard RO + Water softener + Pressure tank
5 stage (Water softener + 5μ PP filter + Compressed activated carbon filter + 1μ PP filter + RO)
Products Advantage & Application
Product advantages:
1. Intelligent controller: one key start, intelligent control, online detection of inlet / outlet water quality, intelligent cleaning of RO membrane, online display of operation status.
2. Flushing solenoid valve: pure brass structure, reliable quality and more stable operation.
3. Water shortage protection: protect the machine and stop automatically when there is water shortage, which makes you feel more secure.
4. Pressure gauge and flowmeter: 304 stainless steel pressure gauge, show clean water flow / concentrated water flow, clear at a glance.
5. Electric control cabinet: brand switch and cable, durable and safe.
2. Flushing solenoid valve: pure brass structure, reliable quality and more stable operation.
3. Water shortage protection: protect the machine and stop automatically when there is water shortage, which makes you feel more secure.
4. Pressure gauge and flowmeter: 304 stainless steel pressure gauge, show clean water flow / concentrated water flow, clear at a glance.
5. Electric control cabinet: brand switch and cable, durable and safe.
Application field:
Bottled drinking water, Circulating water for small water plants, Injection molding, Water for steam boilers, Urea solution, Glass water antifreeze, Water for daily chemical washing industry, Chemical industry, Coating process, Electroplating, Medical high-purity water, Community water sales, Hotels, Hospitals, Schools, Units, Canteens, etc.
Buyer's notice:
1. The RO reverse osmosis process produces wastewater, and the water utilization rate is between 30-60%. (the better the source water quality, the higher the utilization rate)
2. The drainage pipeline of the equipment shall not be equipped with any valve and must be kept unblocked.
3. Water tank or pressure tank shall be installed at the purified water outlet of the equipment to store purified water.
(Equipment with pressure tank can be directly connected to the water use point)
4. The water inlet pressure of the equipment shall be above 0.2MPa. (if the water pressure on the installation site is insufficient, a booster pump can be supplied)
2. The drainage pipeline of the equipment shall not be equipped with any valve and must be kept unblocked.
3. Water tank or pressure tank shall be installed at the purified water outlet of the equipment to store purified water.
(Equipment with pressure tank can be directly connected to the water use point)
4. The water inlet pressure of the equipment shall be above 0.2MPa. (if the water pressure on the installation site is insufficient, a booster pump can be supplied)
Products photo
Products Package
RO & Spare parts Package
Delivery & Container loading
Hot Searches