ADL100-EYZ single phase pre-paid meters with intro-control are used for calculating the single active energy respectively on the
frequency of 50/60 Hz. The built-in magnetic of meter can keep the relay on and off .It also supports RF card or remote recharge ,
load controlling and RS485 communication etc. meet the related technical requirements of electronic power meter in the
IEC62053-21, IEC62053-22 standards.
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
ACREL
-
Model Number:
-
ADL100-EYZ
-
Accuracy Class:
-
0.5
-
Output Voltage:
-
220V
-
Operating Temperature:
-
-25-+55℃
-
Dimensions:
-
72*88*70mm
-
Frequency:
-
50HZ-60HZ
-
Certificate:
-
IEC 60512:1988
-
Display:
-
LCD Digital Display
-
Communication:
-
RS 485
-
Current:
-
Access 60A
-
Accuracy:
-
1.0 class
-
Optional:
-
Multi tariff function
-
Size:
-
72*88*70mm
-
Installation:
-
DIN Rail Installation
-
Payment:
-
Online&RF Card
Quick Details
-
Phase:
-
Single Phase
-
Measuring Energy Range:
-
0-99999.9kwh
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
ACREL
-
Model Number:
-
ADL100-EYZ
-
Accuracy Class:
-
0.5
-
Output Voltage:
-
220V
-
Operating Temperature:
-
-25-+55℃
-
Dimensions:
-
72*88*70mm
-
Frequency:
-
50HZ-60HZ
-
Certificate:
-
IEC 60512:1988
-
Display:
-
LCD Digital Display
-
Communication:
-
RS 485
-
Current:
-
Access 60A
-
Accuracy:
-
1.0 class
-
Optional:
-
Multi tariff function
-
Size:
-
72*88*70mm
-
Installation:
-
DIN Rail Installation
-
Payment:
-
Online&RF Card
ADL100-EYZ Single Phase Prepaid Meter
Product Description
Accuracy: kWh Class 1
Frequency
50/60HZ(Optional), Range: 45~65HZ
Auxiliary power supply(self supply):
220Vac(L-N), range:154~264V AC
Pulse output: Pulse output kWh
Consumption: <4VA(Each phase)
Installation: DIN 35mm
Dimension(L*W*H): 72*88*70mm
Active pulse:
Constant: 6400imp/kWh,400imp/kWh
Clock:M ≤0.5s/d
Starting current: 0.04A
Technical parameters
Technical parameters
|
|
ADL100-EY
|
ADL300-EY
|
||
Voltage
|
Nominal voltage
|
220V
|
3*220/380V
|
||
|
Nominal frequency
|
50/60Hz
|
|
||
|
Consumption
|
<4VA(Each phase)
|
|
||
Current
|
Maximum current
|
60A
|
6A,80A
|
||
|
Starting current
|
Connect directly:0.04A,connect via CT:0.002A
|
|
||
|
Consumption
|
<4VA(Maximum current)
|
|
||
Measurement
performance
|
Accuracy
|
Class 1
|
Class 0.5s
|
||
Clock
|
Accuracy
|
Error ≤0.5
|
|
||
Active pulse
|
Width
|
80ms±20ms
|
|
||
|
Constant
|
1600imp/kWh
|
6400imp/kWh
|
||
Communication
|
Interface
|
RS485
|
|
||
|
Protocol
|
MODBUS-RTU
|
|
||
Temperature range
|
Operating
|
-25℃ ~55℃
|
|
||
|
Storage
|
-40℃ ~70℃
|
|
||
Humidity
|
|
≤95%(No condensation)
|
|
||
Altitude
|
|
≤2000m
|
|
Dimensions and wirings