- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
CHHP
-
Model Number:
-
FLN36-12/24
-
Product name:
-
SF6 Load Break Switch
-
Certificate:
-
ISO9001
-
Material:
-
Copper
-
Rated voltage:
-
12kV/24kV
-
Color:
-
Brown
-
Function:
-
Opening/Closing
-
Feature:
-
Low Voltage/High Voltage
-
Application:
-
Switchgear
Quick Details
-
Number of Pole:
-
3
-
Rated Current:
-
630
-
Rated Voltage:
-
12
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
CHHP
-
Model Number:
-
FLN36-12/24
-
Product name:
-
SF6 Load Break Switch
-
Certificate:
-
ISO9001
-
Material:
-
Copper
-
Rated voltage:
-
12kV/24kV
-
Color:
-
Brown
-
Function:
-
Opening/Closing
-
Feature:
-
Low Voltage/High Voltage
-
Application:
-
Switchgear
FLN36-12/24 Indoor AC High Voltage SF6 Load Break Switch Break Switch
The product has "joint-division-ground" three-position arc chamber, with reliable interlocking, high dielectric strength of fracture, design of large creepage path, and its leading-out terminal is protected by a voltage-sharing protection cover. For the cable head installable load break switch, its outgoing end is equipped with touch-type cable connector, the outgoing line is installed with high-voltage cable, equipped in cable branch (distribution) box. The switch has special dynamic seal and fixed seal design, which is reliable, and it is equipped with a voltmeter in a clear position for monitoring in operation to ensure safe operation, which is a new generation of high voltage switchgear for urban power grid.
This product is suitable for three-phase AC 10KV,20KV,50Hz power system, for cut-off, turning off load current, fault current, control, protective circuit and distribution transformer in industrial and mining enterprises, high-rise buildings, residential quarters and prefabricated substation.
MODEL AND MEANING
Technical Sheet
NO. |
Item |
Unit |
Data |
||
FLN36-12D(24D) |
FLRN36-12D(24D) |
||||
1 |
Rated voltage |
kV |
12 (24) |
12 (24) |
|
2 |
Rated frequency |
Hz |
50 (50) |
50 (50) |
|
3 |
Rated current |
A |
630 (630) |
125 (125) |
|
4 |
Rated short time withstand current of load break switch/rated duration of short-circuit |
kA/s |
20/3 (20/3) |
- |
|
Rated short time withstand current of earthing switch/rated duration of short-circuit |
kA/s |
20/2 (20/2) |
- |
||
5 |
Rated peak withstand current and Rated Short circuit Making Current |
kA |
50 (50) |
125 (Expected) (125) |
|
6 |
Rated breaking current |
Active load breaking current |
A |
630 (630) |
- |
Closed loop breaking current |
A |
630 (630) |
- |
||
5% rated active load breaking current |
A |
31.5 (31.5) |
- |
||
Breaking cable charging current |
A |
10 (10) |
- |
||
Breaking non-load transformer capacity |
kVA |
1250 (2000) |
1250 (2000) |
||
Breaking transfer current |
A |
- |
1700 (1700) |
||
Expected short circuit breaking current |
kA |
- |
20 (50) |
||
7 |
Rated insulation levels |
1min P.F, withstand voltage, phase to phase, earth/across open contacts |
kV |
42/48 (65/79) |
42/48 (65/79) |
Lightning impulse withstand voltage, phase to phase, earth/across open contacts |
kV |
75/85 (125/145) |
75/85 (125/145) |
||
8 |
Mechanical life |
|
5000 (5000) |
5000 (5000) |
|
9 |
Rated pressure of SF6 (20℃, gauge pressure) |
MPa |
0.04~0.05 (0.04~0.05) |
0.04~0.05 (0.04~0.05) |
OUTLINE AND INSTALLATION DIMENSION