Quick Details
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Xindun solar
-
Model Number:
-
XD-HP Pro hybrid solar inverter
-
Input Voltage:
-
24VDC 48VDC
-
Output Voltage:
-
220V±2% / 230V±2% / 240V±2%
-
Output Current:
-
60A~120A
-
Output Frequency:
-
50Hz/60Hz
-
Size:
-
400x315x101.5mm~440x342x101.5mm
-
Certificate:
-
CE RoHS
-
Warranty:
-
12 months
-
Weight:
-
8.5kg~10kg
-
Color:
-
White or Customized Color solar inverter
-
Waveform:
-
Puer Sine Wave output solar Inverter
-
Protection:
-
Short Circuit/Overload/Over Voltage etc.
-
Application:
-
Hybrid solar inverter used for Fan, Pump, Light, solar inverter system
-
Product name:
-
Pure Sine Wave Off-Grid Electric Solar Charge Controller Inverter
-
Keyword:
-
5.5kw 5kva 3kva hybrid solar inverter 5.5kw 5kva 5 kw
-
Battery type:
-
Lead Acid Battery \ Lithium ion Battery \ Gel Battery
-
Display:
-
LCD+LED Display Solar Inverter
-
power:
-
3kva 5kva 3000 watt 5kv 5 kw 5.5kw
-
Controller type:
-
MPPT solar controller inverter
Quick Details
-
Output Type:
-
Single phase solar inverter
-
Type:
-
DC/AC Solar Inverter
-
Inverter Efficiency:
-
99%
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Xindun solar
-
Model Number:
-
XD-HP Pro hybrid solar inverter
-
Input Voltage:
-
24VDC 48VDC
-
Output Voltage:
-
220V±2% / 230V±2% / 240V±2%
-
Output Current:
-
60A~120A
-
Output Frequency:
-
50Hz/60Hz
-
Size:
-
400x315x101.5mm~440x342x101.5mm
-
Certificate:
-
CE RoHS
-
Warranty:
-
12 months
-
Weight:
-
8.5kg~10kg
-
Color:
-
White or Customized Color solar inverter
-
Waveform:
-
Puer Sine Wave output solar Inverter
-
Protection:
-
Short Circuit/Overload/Over Voltage etc.
-
Application:
-
Hybrid solar inverter used for Fan, Pump, Light, solar inverter system
-
Product name:
-
Pure Sine Wave Off-Grid Electric Solar Charge Controller Inverter
-
Keyword:
-
5.5kw 5kva 3kva hybrid solar inverter 5.5kw 5kva 5 kw
-
Battery type:
-
Lead Acid Battery \ Lithium ion Battery \ Gel Battery
-
Display:
-
LCD+LED Display Solar Inverter
-
power:
-
3kva 5kva 3000 watt 5kv 5 kw 5.5kw
-
Controller type:
-
MPPT solar controller inverter
GP-C Series
Solar
Inverter
◆ Soft-start function
◇ DC/AC isolation
◆ Pure sine wave output
◇ Excellent load adaptability and stability
◆ Strong startup ability, high efficiency conversion
◇ Industrial universal socket designed for wide applicability
◆ Small volume, light, safe to use, portable
◇ Protection against over-heating,over-voltage,under-voltage,over load and short-circuits
Df Series Solar Inverter
◆
Supports internal and external two LCD screen display, and theexternal LCD is one key operation.
◇ Micro-processing chip design to improve the computing speedand stability of the equipment.
◆ LCD display, setting parameters and equipment operating status.- The adjustable mains charging current range is 0-30A.
◇ Working modes: grid priority, inverter priority.
◆ Optional built-in PwM or MPPT solar controller to achievehigh-efficiency charging.
◇ Support diesel and gasoline generators, suitable for various gridpower.
◇ Micro-processing chip design to improve the computing speedand stability of the equipment.
◆ LCD display, setting parameters and equipment operating status.- The adjustable mains charging current range is 0-30A.
◇ Working modes: grid priority, inverter priority.
◆ Optional built-in PwM or MPPT solar controller to achievehigh-efficiency charging.
◇ Support diesel and gasoline generators, suitable for various gridpower.
◆
With Toroidal low-loss transformer, high-efficiency inverter conversion, pure sine wave output.
◇ Intelligent LCD display.
◆ Provide adjustable working modes: mains priority, inverter priority.
◇ Optional built-in Mppt solar controller to achieve high-efficiency charging.
◆ Support diesel and gaso;ine generators, suitable for various grid power.
◇ Support RS485 communication / mobile APP (optional).
◇ Intelligent LCD display.
◆ Provide adjustable working modes: mains priority, inverter priority.
◇ Optional built-in Mppt solar controller to achieve high-efficiency charging.
◆ Support diesel and gaso;ine generators, suitable for various grid power.
◇ Support RS485 communication / mobile APP (optional).
![](https://cdn.bestsuppliers.com/seo_products_img/xindunpower/3201cc3d89943b0fbb576cdfde8a1346.jpg!/rotate/180)
Feature
1. High frequency design, high power density, small size, high efficiency, low no-load loss.
2. Built-in MPPT or PWM solar charge controller optional.
3. Pure sine wave output,any types of loads adaptable.
4. Battery charge and discharge voltage parameters adjustable,suitable for different types of
batteries,can prolong the life of the battery and improve system performance.
5. The charging current can be set, battery capacity configuration more flexible.
6. Three working modes adjustable:AC first,Battery first,PV first.
7. Output voltage/frequency adjustable function,adapt to different grid environment.
8. Extra wide voltage and frequency input range, support mains or generator.
9. LED+LCD display, easy operation and data checking,can set each function and data directly.
10. Multi-protection function(overload,over temperature,short circuit protection and so on).
11. RS485 communication port/APP optional.
Highlight
Product Detail
Specification
Specification
|
|
|
|
|
|
|
||||||
Model: HP pro-T
|
|
|
32224L
|
32224
|
50248L
|
50248
|
||||||
Rated Power
|
|
|
3200W
|
3200W
|
5000W
|
5000W
|
||||||
Peak Power(20ms)
|
|
|
9.6KVA
|
9.6KVA
|
15KVA
|
15KVA
|
||||||
Battery Voltage
|
|
|
24VDC
|
24VDC
|
48VDC
|
|
||||||
Product Size(L*W*Hmm)
|
|
|
400x315x101.5
|
|
440x342x101.5
|
|
||||||
Package Size(L*W*Hmm)
|
|
|
488x393x198
|
|
528x420x198
|
|
||||||
N.W(Kg)
|
|
|
8.5
|
|
10
|
|
||||||
G.W(Kg)
|
|
|
9.5
|
|
11
|
|
||||||
Installation Method
|
|
|
Wall-Mounted
|
|
|
|
||||||
PV
|
Charging Mode
|
|
MPPT
|
|
|
|
||||||
|
MPPT tracking voltage range
|
|
30V-100VDC
|
120V-450VDC
|
60V-140VDC
|
120V-450VDC
|
||||||
|
Rated (recommended) operating voltage of PV array
|
|
30V-60VDC
|
360VDC
|
60V-90VDC
|
360VDC
|
||||||
|
Max PV Input Voltage Voc
(At the lowest temperature) |
|
120VDC
|
500VDC
|
180VDC
|
500VDC
|
||||||
|
PV Array Maximum Power
|
|
1680W
|
4000W
|
3360W
|
6000W
|
||||||
|
MPPT tracking channels (input channels)
|
|
1
|
|
|
|
||||||
Input
|
DC Input Voltage Range
|
|
21VDC-30VDC
|
|
42VDC-60VDC
|
|
||||||
|
Rated AC input voltage
|
|
220VAC / 230VAC / 240VAC
|
|
|
|
||||||
|
AC Input Voltage Range
|
|
170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode)
|
|
|
|
||||||
|
AC Input Frequency Range
|
|
45Hz~55Hz(50Hz),55Hz~65Hz(60Hz)
|
|
|
|
||||||
Output
|
Output efficiency(Battery/PV Mode)
|
|
94%(Peak value)
|
|
|
|
||||||
|
Output Voltage(Battery/PV Mode)
|
|
220VAC±2% / 230VAC±2% / 240VAC±2%
|
|
|
|
||||||
|
Output Frequency(Battery/PV Mode)
|
|
50Hz±0.5 or 60Hz±0.5
|
|
|
|
||||||
|
Output Wave(Battery/PV Mode)
|
|
Pure Sine Wave
|
|
|
|
||||||
|
Efficiency(AC Mode)
|
|
>99%
|
|
|
|
||||||
|
Output Voltage(AC Mode)
|
|
Follow input
|
|
|
|
||||||
|
Output Frequency(AC Mode)
|
|
Follow input
|
|
|
|
||||||
|
Output waveform distortion
Battery/PV Mode) |
|
≤3%(Linear load)
|
|
|
|
||||||
|
No load loss(Battery Mode)
|
|
≤1% rated power
|
|
|
|
||||||
|
No load loss(AC Mode)
|
|
≤0.5% rated power(charger does not work in AC mode)
|
|
|
|
||||||
Battery
|
Battery
Type |
VRLA Battery
|
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
|
|
|
|
||||||
|
|
Customize battery
|
Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
|
|
|
||||||
|
Maximum charging current (mains + PV)
|
|
120A
|
100A
|
120A
|
100A
|
||||||
|
Max PV Charging Current
|
|
60A
|
100A
|
60A
|
100A
|
||||||
|
Max AC Charging Current
|
|
60A
|
60A
|
60A
|
60A
|
||||||
|
Charging method
|
|
Three-stage (constant current, constant voltage, floating charge)
|
|
|
|
||||||
Protection
|
Battery low voltage alarm
|
|
Battery undervoltage protection value+0.5V(Single battery voltage)
|
|
|
|
||||||
|
Battery low voltage protection
|
|
Factory default: 10.5V(Single battery voltage)
|
|
|
|
||||||
|
Battery over voltage alarm
|
|
Constant charge voltage+0.8V(Single battery voltage)
|
|
|
|
||||||
|
Battery over voltage protection
|
|
Factory default: 17V(Single battery voltage)
|
|
|
|
||||||
|
Battery over voltage recovery voltage
|
|
Battery overvoltage protection value-1V(Single battery voltage)
|
|
|
|
||||||
|
Overload power protection
|
|
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
|
|
|
|
||||||
|
Inverter output short circuit protection
|
|
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
|
|
|
|
||||||
|
Temperature protection
|
|
>90°C(Shut down output)
|
|
|
|
||||||
Working Mode
|
|
|
Mains priority/PV priority/Battery priority(Can be set)
|
|
|
|
||||||
Transfer Time
|
|
|
≤10ms
|
|
|
|
||||||
Display
|
|
|
LCD+LED
|
|
|
|
||||||
Thermal method
|
|
|
Cooling fan in intelligent control
|
|
|
|
||||||
Communication(Optional)
|
|
|
RS485/APP(WIFI monitoring or GPRS monitoring)
|
|
|
|
||||||
Environment
|
Operating temperature
|
|
-10℃~40℃
|
|
|
|
||||||
|
Storage temperature
|
|
-15℃~60℃
|
|
|
|
||||||
|
Noise
|
|
≤55dB
|
|
|
|
||||||
|
Elevation
|
|
2000m(More than derating)
|
|
|
|
||||||
|
Humidity
|
|
0%~95% (No condensation)
|
|
|
|
Wiring Diagram
1. We offer 3 optional working modes (transfer time≤4ms):
1) AC priority mode (d0)
. When the mains power is normal , on the one hand, the mains power charges the battery ; on the other hand, only the mains power supplies power to the load; . When the mains power is abnormal, the inverter will switch to the battery mode, and the battery will supply power to the load .
2) PV priority mode (d1)
. When the solar is normal, if the solar power is greater than the power of the load, the load is completely powered by solar, when the solar power is less than the power of the load, the insufficient part is supplemented by the battery, and the solar and the battery supply power to the load together. If the battery is low volage due to the load, then the inverter will turn to the AC mode for power supply, and the solar will only charge the battery;
. When the solar is abormal, the inverter will directly switch to the AC mode for power supply, and the mains power will charge the battery.
3) Battery priority mode (d2)
. When the inverter has no low-voltage battery alarm, even if the mains power input is normal, the inverter will switch to the battery mode, and the battery will supply power to the load. . When the battery is low voltage (i.e. the voltage of a conventional single battery is 11vdc) and the mains power input is normal, the inverter will switch to the AC mode and the mains power will supply power to the load completely, while the solar energy will charge the battery but the mains power does not charge the battery.
1) AC priority mode (d0)
. When the mains power is normal , on the one hand, the mains power charges the battery ; on the other hand, only the mains power supplies power to the load; . When the mains power is abnormal, the inverter will switch to the battery mode, and the battery will supply power to the load .
2) PV priority mode (d1)
. When the solar is normal, if the solar power is greater than the power of the load, the load is completely powered by solar, when the solar power is less than the power of the load, the insufficient part is supplemented by the battery, and the solar and the battery supply power to the load together. If the battery is low volage due to the load, then the inverter will turn to the AC mode for power supply, and the solar will only charge the battery;
. When the solar is abormal, the inverter will directly switch to the AC mode for power supply, and the mains power will charge the battery.
3) Battery priority mode (d2)
. When the inverter has no low-voltage battery alarm, even if the mains power input is normal, the inverter will switch to the battery mode, and the battery will supply power to the load. . When the battery is low voltage (i.e. the voltage of a conventional single battery is 11vdc) and the mains power input is normal, the inverter will switch to the AC mode and the mains power will supply power to the load completely, while the solar energy will charge the battery but the mains power does not charge the battery.
Application
Packing & Delivery
Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
Payment
|
|
|
||
T/T
|
EXW
|
30% T/T in advance, balance paid before dispatch
|
||
|
FOB
|
|
||
|
CNF(CFR)
|
30% T/T in advance, balance paid against copy of B/L
|
||
|
CIF
|
|
||
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional)
|
|
|
Hot Searches