Quick Details
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
Goodwe
-
Model Number:
-
DNS Series 3~6KW;MS Series 5~10KW
-
Input Voltage:
-
80-550 V
-
Output Voltage:
-
220 / 230V
-
Output Current:
-
13.6-27.3A
-
Output Frequency:
-
50/60Hz
-
Size:
-
354/ 433 /147
-
Certificate:
-
CE/IEC
-
Warranty:
-
10 Years
-
Weight:
-
13-13.5kg
-
Product name:
-
Goodwe On-Grid Solar Inverter
-
PV Input Power:
-
3KW-6KW
-
MPPT Voltage Range:
-
80-550 V
-
Max. Input Current per MPPT (A):
-
11-13A
-
Number of MPP Trackers:
-
2
-
Number of Strings per MPPT:
-
1
-
Max. Total Harmonic Distortion:
-
<3%
-
DC Surge Protection:
-
Type III
-
AC Surge Protection:
-
Type III
-
User Interface:
-
LED, LCD (Optional), WLAN + APP
Quick Details
-
Output Type:
-
Single
-
Type:
-
DC/AC Inverters
-
Inverter Efficiency:
-
97.8%
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
Goodwe
-
Model Number:
-
DNS Series 3~6KW;MS Series 5~10KW
-
Input Voltage:
-
80-550 V
-
Output Voltage:
-
220 / 230V
-
Output Current:
-
13.6-27.3A
-
Output Frequency:
-
50/60Hz
-
Size:
-
354/ 433 /147
-
Certificate:
-
CE/IEC
-
Warranty:
-
10 Years
-
Weight:
-
13-13.5kg
-
Product name:
-
Goodwe On-Grid Solar Inverter
-
PV Input Power:
-
3KW-6KW
-
MPPT Voltage Range:
-
80-550 V
-
Max. Input Current per MPPT (A):
-
11-13A
-
Number of MPP Trackers:
-
2
-
Number of Strings per MPPT:
-
1
-
Max. Total Harmonic Distortion:
-
<3%
-
DC Surge Protection:
-
Type III
-
AC Surge Protection:
-
Type III
-
User Interface:
-
LED, LCD (Optional), WLAN + APP
Products Description
Smart Monitoring System
Technical specifications
Technical Data
|
GW3000/3600/4200/5000/6000D-NS
GW3000/3600/4200/5000/6000T-DS
|
|
|
|
|
|
|
|
|
|||||||||
Input
|
|
|
|
|
|
|
|
|
|
|||||||||
Max. Input Voltage (V)
|
600
|
|
|
|
|
|
|
|
|
|||||||||
MPPT Operating Voltage Range (V)
|
80~550
|
|
|
|
|
|
|
|
|
|||||||||
Start-up Voltage (V)
|
80
|
|
|
|
|
|
|
|
|
|||||||||
Nominal Input Voltage (V)
|
360
|
|
|
|
|
|
|
|
|
|||||||||
Max. Input Current per MPPT (A)
|
11
|
|
|
|
|
|
|
|
|
|||||||||
Max. Short Circuit Current per MPPT (A)
|
13.8
|
|
|
|
|
|
|
|
|
|||||||||
Number of MPP Trackers
|
2
|
|
|
|
|
|
|
|
|
|||||||||
Number of Strings per MPPT
|
1
|
|
|
|
|
|
|
|
|
|||||||||
Output
|
|
|
|
|
|
|
|
|
|
|||||||||
Nominal Output Power (W)
|
3000
|
3680
|
4200
|
5000
|
6000
|
3000
|
3680
|
4200
|
5000
|
|||||||||
Nominal Output Apparent Power (VA)
|
3000
|
3680
|
4200
|
5000
|
6000
|
3000
|
3680
|
4200
|
5000
|
|||||||||
Max. AC Active Power (W)
|
3000
|
3680
|
4200
|
5000
|
6000
|
3000
|
3680
|
4200
|
5000
|
|||||||||
Max. AC Apparent Power (VA)
|
3000
|
3680
|
4200
|
5000
|
6000
|
3000
|
3680
|
4200
|
5000
|
|||||||||
Nominal Output Voltage (V)
|
220 / 230
|
|
|
|
|
|
|
|
|
|||||||||
Nominal AC Grid Frequency (Hz)
|
50 / 60
|
|
|
|
|
|
|
|
|
|||||||||
Max. Output Current (A)
|
13.6
|
|
|
|
|
|
|
|
|
|||||||||
Power Factor
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
|
|
|
|
|
|
|
|
|||||||||
Max. Total Harmonic Distortion
|
<3%
|
|
|
|
|
|
|
|
|
|||||||||
Efficiency
|
|
|
|
|
|
|
|
|
|
Max. Efficiency
|
97.8%
|
|
|
|
|
|
|
|
|
|||||||||
European Efficiency
|
97.5%
|
|
|
|
|
|
|
|
|
|||||||||
Protection
|
|
|
|
|
|
|
|
|
|
|||||||||
PV String Current Monitoring
|
-
|
|
|
|
|
Integrated
|
|
|
|
|||||||||
PV Insulation Resistance Detection
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
Residual Current Monitoring
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
PV Reverse Polarity Protection
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
Anti-islanding Protection
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
AC Overcurrent Protection
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
AC Short Circuit Protection
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
AC Overvoltage Protection
|
Integrated
|
|
|
|
|
|
|
|
|
|||||||||
DC Switch
|
Optional
|
|
|
|
|
|
|
|
|
|||||||||
DC Surge Protection
|
Type III
|
|
|
|
|
Type III (Type II Optional)
|
|
|
|
|||||||||
AC Surge Protection
|
Type III
|
|
|
|
|
|
|
|
|
|||||||||
AFCI
|
Optional
|
|
|
|
|
Optional
|
|
|
|
|||||||||
Emergency Power Off
|
Optional
|
|
|
|
|
|
|
|
|
|||||||||
Remote Shutdown
|
Optional
|
|
|
|
|
|
|
|
|
|||||||||
General Data
|
|
|
|
|
|
|
|
|
|
|||||||||
Operating Temperature Range (ºC)
|
-25 ~ +60
|
|
|
|
|
|
|
|
|
|||||||||
Relative Humidity
|
0 ~ 100%
|
|
|
|
|
|
|
|
|
|||||||||
Max. Operating Altitude (m)*4
|
4000
|
|
|
|
|
|
|
|
|
|||||||||
Cooling Method
|
Natural Convection
|
|
|
|
|
|
|
|
|
|||||||||
User Interface
|
LED, LCD, WLAN + APP
|
|
|
|
|
|
|
|
|
|||||||||
Communication
|
WiFi, RS485 or 4G or 2G or LAN (Optional)
|
|
|
|
|
|
|
|
|
|||||||||
Weight (kg)
|
13.0
|
13.0
|
13.0
|
13.0
|
13.5
|
13.0
|
13.0
|
13.0
|
13.0
|
|||||||||
Dimension (W × H × D mm)
|
354 × 433 × 147
|
|
|
|
|
|
|
|
|
|||||||||
Noise Emission (dB)
|
<25
|
<25
|
<25
|
<25
|
<50
|
<25
|
<25
|
<25
|
<25
|
|||||||||
Topology
|
Non-isolated
|
|
|
|
|
|
|
|
|
|||||||||
Self-consumption at Night (W)
|
<1
|
|
|
|
|
|
|
|
|
|||||||||
Ingress Protection Rating
|
IP65
|
|
|
|
|
|
|
|
|
|||||||||
DC Connector
|
MC4
|
|
|
|
|
|
|
|
|
|||||||||
AC Connector
|
Plug and play connector
|
|
|
|
|
|
|
|
|
Technical Data
|
GW5000-MS
|
GW6000-MS
|
GW7000-MS
|
GW8500-MS
|
GW10K-MS
|
|||||
Input
|
|
|
|
|
|
|||||
Max.Input Voltage (V)
|
600
|
600
|
600
|
600
|
600
|
|||||
MPPT Operating Voltage Range (V)
|
80 ~ 550
|
80 ~ 550
|
80 ~ 550
|
80 ~ 550
|
80 ~ 550
|
|||||
Start-up Voltage (V)
|
80
|
80
|
80
|
80
|
80
|
|||||
Nominal Input Voltage (V)
|
360
|
360
|
360
|
360
|
360
|
|||||
Max. Input Current per MPPT (A)
|
16
|
16
|
16
|
16
|
16
|
|||||
Max. Short Circuit Current per MPPT (A)
|
20
|
20
|
20
|
20
|
20
|
|||||
Number of MPP Trackers
|
3
|
3
|
3
|
3
|
3
|
|||||
Number of Strings per MPPT
|
1
|
1
|
1
|
1
|
1
|
|||||
Output
|
|
|
|
|
|
|||||
Nominal Output Power (W)
|
5000
|
6000
|
7000
|
8500
|
10000
|
|||||
Nominal Output Apparent Power (VA)
|
5000
|
6000
|
7000
|
8500
|
10000
|
|||||
Max. AC Active Power (W)*1
|
5500
|
6600
|
7700
|
9350
|
10000
|
|||||
Max. AC Apparent Power (VA)*2
|
5500
|
6600
|
7700
|
9350
|
10000
|
|||||
Nominal Output Voltage (V)
|
220 / 230 / 240
|
220 / 230 / 240
|
220 / 230 / 240
|
220 / 230 / 240
|
220 / 230 / 240
|
|||||
Nominal AC Grid Frequency (Hz)
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
50 / 60
|
|||||
Max. Output Current (A)
|
25.0
|
30.0
|
35.0
|
42.5
|
45.5
|
|||||
Power Factor
|
~1 (Adjustable from 0.8 leading to 0.8 lagging)
|
|
|
|
|
|||||
Max. Total Harmonic Distortion
|
<3%
|
<3%
|
<3%
|
<3%
|
<3%
|
|||||
Efficiency
|
|
|
|
|
|
|||||
Max. Efficiency
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
97.7%
|
|||||
European Efficiency
|
97.3%
|
97.3%
|
97.3%
|
97.3%
|
97.3%
|
|||||
Protection
|
|
|
|
|
|
PV Insulation Resistance Detection
|
Integrated
|
|
|
|
|
|||||
Residual Current Monitoring
|
Integrated
|
|
|
|
|
|||||
PV Reverse Polarity Protection
|
Integrated
|
|
|
|
|
|||||
Anti-islanding Protection
|
Integrated
|
|
|
|
|
|||||
AC Overcurrent Protection
|
Integrated
|
|
|
|
|
|||||
AC Short Circuit Protection
|
Integrated
|
|
|
|
|
|||||
AC Overvoltage Protection
|
Integrated
|
|
|
|
|
|||||
DC Switch
|
Integrated
|
|
|
|
|
|||||
DC Surge Protection
|
Type II
|
|
|
|
|
|||||
AC Surge Protection
|
Type III (Type II Optional)
|
|
|
|
|
|||||
AFCI
|
Optional
|
|
|
|
|
|||||
Remote Shutdown
|
Optional
|
|
|
|
|
|||||
General Data
|
|
|
|
|
|
|||||
Operating Temperature Range (°C)
|
-25 ~ +60
|
-25 ~ +60
|
-25 ~ +60
|
-25 ~ +60
|
-25 ~ +60
|
|||||
Relative Humidity
|
0 ~ 100%
|
0 ~ 100%
|
0 ~ 100%
|
0 ~ 100%
|
0 ~ 100%
|
|||||
Max. Operating Altitude (m)*3
|
4000
|
4000
|
4000
|
4000
|
4000
|
|||||
Cooling Method
|
Natural Convection
|
Natural Convection
|
Natural Convection
|
Natural Convection
|
Natural Convection
|
|||||
User Interface
|
LED, LCD
|
LED, LCD
|
LED, LCD
|
LED, LCD
|
LED, LCD
|
|||||
Communication
|
WiFi, RS485 or LAN (Optional)
|
|
|
|
|
|||||
Communication Protocols
|
Modbus-RTU (SunSpec Compliant)
|
|
|
|
|
|||||
Weight (kg)
|
22.5
|
22.5
|
22.5
|
22.5
|
22.5
|
|||||
Dimension (W × H × D mm)
|
415 × 511 × 175
|
415 × 511 × 175
|
415 × 511 × 175
|
415 × 511 × 175
|
415 × 511 × 175
|
|||||
Topology
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
Non-isolated
|
|||||
Self-consumption at Night (W)
|
<1
|
<1
|
<1
|
<1
|
<1
|
|||||
Ingress Protection Rating
|
IP65
|
IP65
|
IP65
|
IP65
|
IP65
|
|||||
DC Connector
|
MC4 (4 ~ 6mm²)
|
MC4 (4 ~ 6mm²)
|
MC4 (4 ~ 6mm²)
|
MC4 (4 ~ 6mm²)
|
MC4 (4 ~ 6mm²)
|
Product packaging
Our Factory
Project Cases
Request Complete System
Contact Us
FAQ
Q1.How to solve the technical problem?
A:24 hours after-service consultancy just for you and to make your problem to solve easily.
Q2.What is your Delivery time?
A:Usually, we make merchandise inventory, if we have the products in stock,The delivery time is 5-10 days after receiving the deposit; If we don’t have the products in stock, we will arrange the production right now, the delivery time will be 10-30days,It depends on the quantity of order
Q3.Why should we choose you?
A:1: Reliable company - 14 years manufacturing and exporting experience.
2: Qualified products - TUV, CE, UL, IEC, CEC, INMETRO, ISO certified.
3: Good payment term for clients.
4: Module with lower degradation rate than standard degradation in the PV field
Q4.How to proceed an order?
A:1.let us know your requirements or application.
2. We quote according to your requirements or our suggestions.
3. Customer confirms the samples and pay deposit for formal order.
4. We arrange the production.
If you want to know more information, you can send inquiry to our team, we will cover more details.