- Product Details
- {{item.text}}
Quick Details
-
Jacket:
-
PVC
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Greater
-
Model Number:
-
YJV32
-
Size:
-
100M/200M/500M/1000M /OEM
-
Voltage:
-
0.6/1KV
-
Standard:
-
IEC60502, IEC60332, lEC60754.
-
Certificate:
-
CE
-
No. of Conductor:
-
Single Core /2 /3 /4/3+1 cores/ 4+1cores / 5 cores /3+2 cores
-
Conductor:
-
Copper
-
Insulation:
-
XLPE
-
Sheath:
-
PVC
-
Temperature:
-
90℃
-
Keyword:
-
Copper Core 240mm2 630mm2 1400mm2 110Kv Underground Cable
-
Warranty:
-
1 Year
Quick Details
-
Insulation Material:
-
Xlpe
-
Application:
-
Industrial
-
Conductor Material:
-
Copper
-
Jacket:
-
PVC
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Greater
-
Model Number:
-
YJV32
-
Size:
-
100M/200M/500M/1000M /OEM
-
Voltage:
-
0.6/1KV
-
Standard:
-
IEC60502, IEC60332, lEC60754.
-
Certificate:
-
CE
-
No. of Conductor:
-
Single Core /2 /3 /4/3+1 cores/ 4+1cores / 5 cores /3+2 cores
-
Conductor:
-
Copper
-
Insulation:
-
XLPE
-
Sheath:
-
PVC
-
Temperature:
-
90℃
-
Keyword:
-
Copper Core 240mm2 630mm2 1400mm2 110Kv Underground Cable
-
Warranty:
-
1 Year
Products Description
Brief of XLPE Insulated Power Cable
XLPE insulated power cable has a number of advantages over paper insulated and PVC
insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resistance, environmental stressresisting anti-chemicalcorrosion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Various of flame-retardant and non-flameretardant XLPE cable can be manufacturedwith three technology (peroxide, silence, and iradiation, cross linking). The flame-retardant cable covers all kinds of low-smoke, low-halogen, low-smoke halogen free and non-smoke no halogenated and three classes of A,B, C.
Our XLPE cable can be manufactured according to company's specification which is equivalent to IEC60502, IEC60332, IEC60754. Some of indexes are superior to above international standard IEC.
Some of special XLPE cable can be manufactured according to the other standards required by customs.
XLPE cable having higher long-tem working temperature and greater current rating, ar the same environment XLPE cable may be reduced size (nominal cross section) 1 or 2 class in comparison with paper and PVC cable. These are not only improving the quality and properties of products, but also reduce cable's production costs.
insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resistance, environmental stressresisting anti-chemicalcorrosion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Various of flame-retardant and non-flameretardant XLPE cable can be manufacturedwith three technology (peroxide, silence, and iradiation, cross linking). The flame-retardant cable covers all kinds of low-smoke, low-halogen, low-smoke halogen free and non-smoke no halogenated and three classes of A,B, C.
Our XLPE cable can be manufactured according to company's specification which is equivalent to IEC60502, IEC60332, IEC60754. Some of indexes are superior to above international standard IEC.
Some of special XLPE cable can be manufactured according to the other standards required by customs.
XLPE cable having higher long-tem working temperature and greater current rating, ar the same environment XLPE cable may be reduced size (nominal cross section) 1 or 2 class in comparison with paper and PVC cable. These are not only improving the quality and properties of products, but also reduce cable's production costs.
Product Paramenters
Single Core
Nominal Cross Saction
|
Over all Dia.
|
Nominal Thickness of insulation
|
Size of Armour
|
|
|
Approx, Over all Diameter & Weight
|
|
Recommending Curent Rating
|
|
||||
|
|
|
Steel Tape
|
Fine Steel Wire
|
Thick Steel Wire
|
YJV32
|
|
|
|
||||
|
|
|
Layer x Thickness
|
Dia.
|
Dia.
|
Over all Dia.
|
Weight
|
In Ground
|
In Air
|
||||
mm
|
mm
|
mm
|
|
mm
|
mm
|
mm
|
kg/km
|
A
|
A
|
||||
1.5
|
1.38
|
0.7
|
2x0.3
|
1.6
|
4.0
|
16.9
|
594
|
45
|
32
|
||||
2.5
|
1.78
|
0.7
|
2x0.3
|
1.6
|
4.0
|
16.9
|
601
|
59
|
42
|
||||
4
|
2.25
|
0.7
|
2x0.3
|
1.6
|
4.0
|
16.9
|
614
|
77
|
56
|
||||
6
|
2.76
|
0.7
|
2x0.3
|
1.6
|
4.0
|
16.9
|
625
|
97
|
70
|
||||
10
|
3.57
|
0.7
|
2x0.3
|
1.6
|
4.0
|
16.9
|
655
|
130
|
97
|
||||
16
|
4.50
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.0
|
702
|
170
|
125
|
||||
25
|
6.30
|
0.9
|
2x0.3
|
1.6
|
4.0
|
17.4
|
778
|
220
|
165
|
||||
35
|
7.30
|
0.9
|
2x0.3
|
1.6
|
4.0
|
18.4
|
919
|
265
|
200
|
||||
50
|
8.30
|
1.0
|
2x0.3
|
1.6
|
4.0
|
19.6
|
1111
|
320
|
245
|
||||
70
|
10.00
|
1.1
|
2x0.3
|
1.6
|
4.0
|
21.5
|
1394
|
295
|
305
|
||||
95
|
11.60
|
1.1
|
2x0.3
|
1.6
|
4.0
|
23.1
|
1699
|
475
|
375
|
||||
120
|
13.00
|
1.2
|
2x0.3
|
1.6
|
4.0
|
24.7
|
1991
|
545
|
435
|
||||
150
|
14.60
|
1.4
|
2x0.3
|
1.6
|
4.0
|
26.7
|
2375
|
610
|
500
|
||||
185
|
16.20
|
1.6
|
2x0.3
|
1.6
|
4.0
|
28.8
|
1791
|
695
|
580
|
||||
240
|
18.60
|
1.7
|
2x0.3
|
1.6
|
4.0
|
31.6
|
3445
|
810
|
685
|
||||
300
|
20.80
|
1.8
|
2x0.3
|
1.6
|
4.0
|
34.2
|
4126
|
910
|
795
|
||||
400
|
24.30
|
2.0
|
2x0.3
|
2.0
|
4.0
|
39.3
|
5570
|
1050
|
930
|
||||
500
|
28.80
|
2.2
|
2x0.5
|
2.0
|
4.0
|
44.3
|
6647
|
1190
|
108
|
||||
630
|
33.00
|
2.4
|
2x0.5
|
2.0
|
4.0
|
50.4
|
8798
|
1350
|
1250
|
||||
800
|
37.29
|
2.6
|
2x0.5
|
2.0
|
4.0
|
55.6
|
10790
|
1520
|
1440
|
||||
1000
|
41.80
|
2.8
|
2x0.5
|
2.0
|
4.0
|
60.9
|
13135
|
1690
|
1630
|
Two Cores
Nominal Cross Saction
|
Nominal Thickness of insulation
|
Size of Armour
|
|
|
Approx, Over all Diameter & Weight
|
|
Recommending Curent Rating
|
|
||||
|
|
Steel Tape
|
Fine Steel Wire
|
Thick Steel Wire
|
YJV32
|
|
|
|
||||
|
|
Layer x Thickness
|
Dia.
|
Dia.
|
Over all Dia.
|
Weight
|
In Ground
|
In Air
|
||||
mm
|
mm
|
|
mm
|
mm
|
mm
|
kg/km
|
A
|
A
|
||||
1.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.1
|
543
|
40
|
34
|
||||
2.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.0
|
557
|
50
|
45
|
||||
4
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.0
|
582
|
65
|
55
|
||||
6
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.1
|
617
|
82
|
70
|
||||
10
|
0.7
|
2x0.3
|
1.6
|
4.0
|
18.8
|
763
|
120
|
99
|
||||
16
|
0.7
|
2x0.3
|
1.6
|
4.0
|
20.6
|
948
|
140
|
120
|
||||
25
|
0.9
|
2x0.3
|
1.6
|
4.0
|
22.2
|
1301
|
180
|
160
|
||||
35
|
0.9
|
2x0.3
|
1.6
|
4.0
|
23.7
|
1536
|
215
|
200
|
||||
50
|
1.0
|
2x0.3
|
1.6
|
4.0
|
25.7
|
1881
|
255
|
240
|
||||
70
|
1.1
|
2x0.3
|
2.0
|
4.0
|
29.4
|
2628
|
315
|
300
|
||||
95
|
1.1
|
2x0.3
|
2.0
|
4.0
|
32.0
|
3247
|
380
|
375
|
||||
120
|
1.2
|
2x0.5
|
2.0
|
4.0
|
34.7
|
3897
|
430
|
430
|
||||
150
|
1.4
|
2x0.5
|
2.5
|
4.0
|
38.9
|
4990
|
480
|
490
|
||||
185
|
1.6
|
2x0.5
|
2.5
|
4.0
|
42.2
|
5927
|
540
|
570
|
Three Core
Nominal Cross Saction
|
Nominal Thickness of insulation
|
Size of Armour
|
|
|
Approx, Over all Diameter & Weight
|
|
Recommending Curent Rating
|
|
||||
|
|
Steel Tape
|
Fine Steel Wire
|
Thick Steel Wire
|
YJV32
|
|
|
|
||||
|
|
Layer x Thickness
|
Dia.
|
Dia.
|
Over all Dia.
|
Weight
|
In Ground
|
In Air
|
||||
mm
|
mm
|
|
mm
|
mm
|
mm
|
kg/km
|
A
|
A
|
||||
1.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.1
|
557
|
28
|
21
|
||||
2.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.0
|
582
|
38
|
30
|
||||
4
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.1
|
621
|
50
|
49
|
||||
6
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.8
|
700
|
65
|
55
|
||||
10
|
0.7
|
2x0.3
|
1.6
|
4.0
|
19.5
|
885
|
89
|
78
|
||||
16
|
0.7
|
2x0.3
|
1.6
|
4.0
|
21.5
|
1141
|
115
|
105
|
||||
25
|
0.9
|
2x0.3
|
1.6
|
4.0
|
26.6
|
1670
|
150
|
140
|
||||
35
|
0.9
|
2x0.3
|
1.6
|
4.0
|
28.8
|
2033
|
180
|
170
|
||||
50
|
1.0
|
2x0.3
|
1.6
|
4.0
|
31.8
|
2513
|
215
|
205
|
||||
70
|
1.1
|
2x0.3
|
2.0
|
4.0
|
36.1
|
3502
|
265
|
260
|
||||
95
|
1.1
|
2x0.5
|
2.0
|
4.0
|
39.4
|
4392
|
315
|
320
|
||||
120
|
1.2
|
2x0.5
|
2.0
|
4.0
|
42.4
|
5258
|
360
|
370
|
||||
150
|
1.4
|
2x0.5
|
2.5
|
4.0
|
46.9
|
6706
|
405
|
430
|
||||
185
|
1.6
|
2x0.5
|
2.5
|
4.0
|
51.1
|
8104
|
460
|
490
|
||||
240
|
1.7
|
2x0.5
|
2.5
|
4.0
|
56.1
|
10062
|
530
|
580
|
||||
300
|
1.8
|
2x0.5
|
2.5
|
4.0
|
60.6
|
12082
|
590
|
660
|
||||
400
|
2.0
|
2x0.5
|
3.15
|
4.0
|
68.5
|
15744
|
670
|
750
|
Four Cores
Nominal Cross Saction
|
Nominal Thickness of insulation
|
Size of Armour
|
|
|
Approx, Over all Diameter & Weight
|
|
Recommending Curent Rating
|
|
||||
|
|
Steel Tape
|
Fine Steel Wire
|
Thick Steel Wire
|
YJV32
|
|
|
|
||||
|
|
Layer x Thickness
|
Dia.
|
Dia.
|
Over all Dia.
|
Weight
|
In Ground
|
In Air
|
||||
mm
|
mm
|
|
mm
|
mm
|
mm
|
kg/km
|
A
|
A
|
||||
1.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.0
|
593
|
28
|
21
|
||||
2.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
18.0
|
663
|
38
|
30
|
||||
4
|
0.7
|
2x0.3
|
1.6
|
4.0
|
19.1
|
770
|
50
|
49
|
||||
6
|
0.7
|
2x0.3
|
1.6
|
4.0
|
20.3
|
916
|
65
|
55
|
||||
10
|
0.7
|
2x0.3
|
1.6
|
4.0
|
22.3
|
1148
|
89
|
78
|
||||
16
|
0.7
|
2x0.3
|
1.6
|
4.0
|
24.5
|
1472
|
115
|
105
|
||||
25
|
0.9
|
2x0.3
|
1.6
|
4.0
|
27.5
|
1942
|
150
|
140
|
||||
35
|
0.9
|
2x0.3
|
1.6
|
4.0
|
29.5
|
2386
|
180
|
170
|
||||
50
|
1.0
|
2x0.3
|
2.0
|
4.0
|
32.9
|
3206
|
215
|
205
|
||||
70
|
1.1
|
2x0.5
|
2.0
|
4.0
|
36.7
|
4197
|
265
|
260
|
||||
95
|
1.1
|
2x0.5
|
2.0
|
4.0
|
40.5
|
5362
|
315
|
320
|
||||
120
|
1.2
|
2x0.5
|
2.5
|
4.0
|
45.3
|
6908
|
360
|
370
|
||||
150
|
1.4
|
2x0.5
|
2.5
|
4.0
|
50.0
|
8327
|
405
|
430
|
||||
185
|
1.6
|
2x0.5
|
2.5
|
4.0
|
54.2
|
10044
|
460
|
490
|
||||
240
|
1.7
|
2x0.5
|
2.5
|
4.0
|
60.4
|
12672
|
530
|
580
|
||||
300
|
1.8
|
2x0.5
|
2.5
|
4.0
|
65.7
|
15302
|
590
|
660
|
||||
400
|
2.0
|
2x0.5
|
3.15
|
4.0
|
74.2
|
19969
|
670
|
750
|
Five Cores
Nominal Cross Saction
|
Nominal Thickness of insulation
|
Size of Armour
|
|
|
Approx, Over all Diameter & Weight
|
|
Recommending Curent Rating
|
|
||||
|
|
Steel Tape
|
Fine Steel Wire
|
Thick Steel Wire
|
YJV32
|
|
|
|
||||
|
|
Layer x Thickness
|
Dia.
|
Dia.
|
Over all Dia.
|
Weight
|
In Ground
|
In Air
|
||||
mm
|
mm
|
|
mm
|
mm
|
mm
|
kg/km
|
A
|
A
|
||||
1.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
17.8
|
693
|
28
|
21
|
||||
2.5
|
0.7
|
2x0.3
|
1.6
|
4.0
|
18.9
|
796
|
38
|
30
|
||||
4
|
0.7
|
2x0.3
|
1.6
|
4.0
|
20.2
|
925
|
50
|
49
|
||||
6
|
0.7
|
2x0.3
|
1.6
|
4.0
|
21.6
|
1098
|
65
|
55
|
||||
10
|
0.7
|
2x0.3
|
1.6
|
4.0
|
23.8
|
1399
|
89
|
78
|
||||
16
|
0.7
|
2x0.3
|
1.6
|
4.0
|
26.3
|
1791
|
115
|
105
|
||||
25
|
0.9
|
2x0.3
|
1.6
|
4.0
|
33.5
|
2488
|
150
|
140
|
||||
35
|
0.9
|
2x0.3
|
2.0
|
4.0
|
37.7
|
3339
|
180
|
170
|
||||
50
|
1.0
|
2x0.3
|
2.0
|
4.0
|
38.2
|
3932
|
215
|
205
|
||||
70
|
1.1
|
2x0.3
|
2.0
|
4.0
|
41.9
|
5122
|
265
|
260
|
||||
95
|
1.1
|
2x0.5
|
2.5
|
4.0
|
47.9
|
7029
|
315
|
320
|
||||
120
|
1.2
|
2x0.5
|
2.5
|
4.0
|
52.2
|
8487
|
360
|
370
|
||||
150
|
1.4
|
2x0.5
|
2.5
|
4.0
|
55.0
|
10016
|
405
|
430
|
||||
185
|
1.6
|
2x0.5
|
2.5
|
4.0
|
60.5
|
12218
|
460
|
490
|
||||
240
|
1.7
|
2x0.5
|
2.5
|
4.0
|
66.5
|
15353
|
530
|
580
|
||||
300
|
1.8
|
2x0.5
|
2.5
|
4.0
|
73.7
|
19419
|
590
|
660
|
FAQ
Q1: Are you a factory?
A1: The company's main products are low-voltage cables. We are a manufacturer with more than 30 years of experience.
Q2: How about MOQ ?
A2: Generally 100m. The cable is heavy, you'd better order a suitable quantity to avoid high shipping costs. Sea shipping is the best option.
Q3: How long is your delivery time?
A3: Generally it is 5-10 days if wires are in stock. if wires are not in stock, it is according to quantity.
Q4: Can I see the sample first before I place the real order ?
A4: Of course. We can offer samples for testing .
A1: The company's main products are low-voltage cables. We are a manufacturer with more than 30 years of experience.
Q2: How about MOQ ?
A2: Generally 100m. The cable is heavy, you'd better order a suitable quantity to avoid high shipping costs. Sea shipping is the best option.
Q3: How long is your delivery time?
A3: Generally it is 5-10 days if wires are in stock. if wires are not in stock, it is according to quantity.
Q4: Can I see the sample first before I place the real order ?
A4: Of course. We can offer samples for testing .
Q5 : Can I get a discount?
A5:It depends on your quantity. Please contact us.
Q6:When can I get the price?
A6:We usually quote within 5 hours of receiving your inquiry. If you are in a hurry to get a price, please call us or let us know in your email so we can prioritize your inquiry.
Q7: Do you accept OEM/ODM?
A7:We support OEM/ODM service: please don't hesitate to tell us your thoughts. Please feel free to leave your request.
A5:It depends on your quantity. Please contact us.
Q6:When can I get the price?
A6:We usually quote within 5 hours of receiving your inquiry. If you are in a hurry to get a price, please call us or let us know in your email so we can prioritize your inquiry.
Q7: Do you accept OEM/ODM?
A7:We support OEM/ODM service: please don't hesitate to tell us your thoughts. Please feel free to leave your request.