- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
BLS
-
Model Number:
-
BLS-4294
-
Standard:
-
ASTM D4294
-
Function:
-
Test the sulfur content in the petroleum products
-
Application:
-
igh sulfur content oils sulfur measurement
-
Measurement range:
-
7 ppm to 5%
-
Test method:
-
X-ray fluorescence
-
Oil sample quantity:
-
2~3 ml (it is equal to sample depth of 3 mm~4 mm)
-
Measurement time:
-
can preset 60, 120, 240, 300, and 600 s arbitrarily
Quick Details
-
Warranty:
-
1 Year
-
Power:
-
Electronic
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
BLS
-
Model Number:
-
BLS-4294
-
Standard:
-
ASTM D4294
-
Function:
-
Test the sulfur content in the petroleum products
-
Application:
-
igh sulfur content oils sulfur measurement
-
Measurement range:
-
7 ppm to 5%
-
Test method:
-
X-ray fluorescence
-
Oil sample quantity:
-
2~3 ml (it is equal to sample depth of 3 mm~4 mm)
-
Measurement time:
-
can preset 60, 120, 240, 300, and 600 s arbitrarily
ASTM D4294 Sulfur Content in Diesel Oil Analyzer/ Sulphur Content Testing Kit
Application
This instrument is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so it is rapid and accurate. It can meet the requirements of National Standard GB/T 17040 and GB/T11140 on repeatability and reproducibility, and it can also meet requirements of ASTM D4294-03 on these indexes. It provides a measure to determine sulfur content during petroleum or petrochemical production process.
Application Area
(1) It can be used to determine mass% of total sulfur in the crude petroleum, petroleum, heavy oil, diesel oil, gasoline, and naphtha.
(2) It can be used to determine total sulfur content in the products of coal chemical industry, such as primary benzene.
(3) It can be used to determine total sulfur or sulfide in other liquid or solid powder samples.
Technical Parameters
(1) Measuring range:7ppm to 5%
(2) Repeatability (r): <0.02894 (X+0.1691) (3) Reproducibility (R): <0.1215(X+0.5555) (4) Detection limit: 10 ppm (5) Oil sample quantity: (2~3) ml (it is equal to sample depth of 3 mm-4mm) (6) Measurement time: it can preset 60, 120, 240, 300, and 600 s at random (7) It can make measurement automatically for single sample. Repeat times: can set 2, 3, 5, 10, and 50 at random; it will show average value and standard deviation at end of measurement. (8) Calibration curve numbers: it can save 9 calibration curves. 5 pieces of them are unary linear equation and 4 pieces of them are unary quadratic equation. (9) Working condition: Ambient temperature: 5~40ºC Relative humidity: ≤85% (30 ºC) (10) Power supply: AC 220V±20V, 50 Hz; Rated power: 30 W (11) Dimension and weight: 468mm×368mm×136mm; 13 kg |