- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
NEWGOER
-
Model Number:
-
DSC-100
-
Model:
-
DSC-100
-
DSC Range:
-
0~± 600mW
-
Temperature Range:
-
RT ~ 800℃
-
Heating Rate:
-
0.1~80℃/min
-
Temperature Resolution:
-
0.001℃
-
Temperature Fluctuation:
-
±0.001℃
-
DSC Sensitivity:
-
0.01mW
-
Product name:
-
DSC Differential Scanning Calorimeter
-
Function:
-
test the Air permeability resistance of textiles
Quick Details
-
Warranty:
-
1 year, 24 Months
-
Power:
-
Electronic
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
NEWGOER
-
Model Number:
-
DSC-100
-
Model:
-
DSC-100
-
DSC Range:
-
0~± 600mW
-
Temperature Range:
-
RT ~ 800℃
-
Heating Rate:
-
0.1~80℃/min
-
Temperature Resolution:
-
0.001℃
-
Temperature Fluctuation:
-
±0.001℃
-
DSC Sensitivity:
-
0.01mW
-
Product name:
-
DSC Differential Scanning Calorimeter
-
Function:
-
test the Air permeability resistance of textiles
DSC Analyzer Differential Scanning Calorimeter Fully Automatic 800C
Thermal Differential Thermal Analysis Analyzer DSC Machine
Summary:
Ø The Differential Scanning Calorimeter DSC refers to in the temperature control program and a certain atmosphere, measuring the temperature difference between the sample and the reference material is proportional to the rate of heat flow through the thermal plate instrument.
Ø the relevant differential scanning calorimeter technical specifications can be found in the National Metrology regulations (JJG936-1998).
Ø DSC have two main types: the power compensation and heat flux.
Ø Our DSC is heat flow differential scanning calorimeter.
Ø DSC is widely used in the field of polymer development, performance testing & quality control.
Standard:
ISO/TR10837:1991, ASTM D3895-1998, ASTM E 967, ASTM E 968, ASTM E 793,
ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC...
Model Selection
Model | DSC-100 | DSC-100L | DSC-200 | DSC-200L | DSC-300 | DSC300L |
Temperature Rane | RT ~ 800℃ | -100 ~ 800℃ | RT ~ 600℃ | -100 ~ 600℃ | RT ~ 550℃ | -150 ~ 600℃ |
DSC Range | 0~± 600mW | 0~± 600mW | 0~± 500mW | 0~± 500mW | 0~± 600mW | 0~± 600mW |
Cooling Method | Air Cooled | Liquid Nitrogen Cooled | Air Cooled | Liquid Nitrogen Cooled | Air Cooled | Liquid Nitrogen Cooled |
Scanning Method | Heating Scan | Heating Scan | Heating Scan + Cooling Scan |
Speficiations of DSC100 / DSC100L:
Model |
DSC-100 |
DSC-100L |
|
DSC Range |
0~± 600mW |
0~± 600mW |
|
Temperature Range |
RT ~ 800℃ (Air-cooled) |
-100 ~ 800℃ (Liquid Nitrogen Cooling) |
|
Heating Rate |
0.1~80℃/min |
0.1~80℃/min |
|
Temperature Resolution |
0.001℃ |
0.001℃ |
|
Temperature Fluctuation |
±0.001℃ |
±0.001℃ |
|
Temperature Repeatability |
±0.1℃ |
±0.1℃ |
|
DSC Noise |
0.01μW |
0.01μW |
|
DSC Resolution |
0.01μW |
0.01μW |
|
DSC Accuracy |
0.01mW |
0.01mW |
|
DSC Sensitivity |
0.01mW |
0.01mW |
|
Temperature Control Mode |
Rising Temp, Constant Temp, Cooling Temp (Full Automatic Programmed Control) |
||
Curve Scanning |
Rising Scan |
Rising Scan |
|
Atmosphere Control Gas |
|||
Gas Flow Rate |
0-300mL/min |
0-300mL/min |
|
Gas Pressure |
0.2MPa |
0.2MPa |
|
Display method |
7-inch LCD Touch Screen |
7-inch LCD Touch Screen |
|
Communication Interface |
Standard USB interface |
Standard USB interface |
|
Parameters Standard |
Equip with Standard Materials (INDIUM, TIN) |
||
Software |
4 in 1 operating software |
||
Thermocouple |
Total 3 sets of thermocouples for: 1). Test Sample Temperature 2). Test Furnace Temperature, 3). Test Internal Ambient Temperature |
Features:
1. The industrial-grade 7-inch touch screen displays rich information.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.