- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
OEM
-
Model Number:
-
OHSP350S
-
Focal Length:
-
42mm, 42mm
-
Wavelength Range:
-
350-950
-
Product name:
-
OHSP305S nir spectrometer
-
Stray light:
-
≤0.3%
-
Spectral bandwidth (FWHM):
-
2nm
-
Frequency range:
-
25-1KHz
-
CCT range:
-
1,000K~ 100,000K
-
Chromaticity coordinate accuracy:
-
±0.0025
-
Application:
-
Medical Beauty Light source
-
Frequency sampling rate:
-
1-10KHz
Quick Details
-
Size:
-
138.5*81*23mm, 138.5*81*23mm
-
Weight:
-
430g
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
OEM
-
Model Number:
-
OHSP350S
-
Focal Length:
-
42mm, 42mm
-
Wavelength Range:
-
350-950
-
Product name:
-
OHSP305S nir spectrometer
-
Stray light:
-
≤0.3%
-
Spectral bandwidth (FWHM):
-
2nm
-
Frequency range:
-
25-1KHz
-
CCT range:
-
1,000K~ 100,000K
-
Chromaticity coordinate accuracy:
-
±0.0025
-
Application:
-
Medical Beauty Light source
-
Frequency sampling rate:
-
1-10KHz
OHSP350S/SF
spectral irradiance colorimeter , extends wider wavelength
to350-950nm.add the latest and most authoritative evaluation of light source
color rendering Methods TM-30-2015 .it is suitable for measuring all light
source, Such as solar radiation spectrum, medical light sources, grow
light,365nm UV light, 850 nm infrared LED etc.
Meas parameters Wave range:350-950nm
CCT(K) | Irradiance(W/m2) | Peak wave(nm) | illumination(lx) |
TM-30-2015 Rf | Coordinate x,y | Spectral Distribution | TLCI-2012 |
TM-30-2015 Rg | Plant parameters PAR,PPFD | OHSP350 Basic parameters | CRI(Ra) |
350SF Parameters
PPFD(umol/m2/s) | Blue light hazard irradiance Be (mW/cm2) | TM-30 |
YPFD(umol/m2/s) | Risk Hints | Flicker Curve |
PAR(mW/cm2) | Blue light ratio Bek (mW/cm2) | Modulation depth % |
Kppfv(umol/s/klm) | Exposable time S | TLCI-2012 |
Ech-A (mW/cm2) | Flicker Frequency (Hz) | |
Ech-B (mW/cm2) | Flicker Percent(%) |
Model |
OHSP-350S flagship version |
Wavelength range |
3 5 0nm ~ 950 nm |
Splitting mode |
Long-focus cross asymmetric CT optical system |
Sensor |
High-precision CCD |
By light device |
10 mm Cosine corrector |
Spectral resolution |
0.2nm X, Y repetitive ± 0.0005 |
Wavelength accuracy |
±0.5nm |
Illumination accuracy |
(± 4 % Reading +1 Digita l ) |
Spectral bandwidth (FWHM) |
2nm |
TM-30 chromaticity parameters |
YES |
Plant growth light parameters |
YES |
Accuracy of chromaticity coordinates |
±0.0025(Relative to the standard light source whose stability is better than ±0.0005and NIM traceable calibrated value) |
CCT range |
1,000K ~ 100,000K |
Stray light |
≤ 0.3% |
Illuminance measurement range |
5 lx ~ 200klx |
Integration time |
5 0µs ~ 1 0000ms |