- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
GOLD
-
Model Number:
-
GD-125
-
Product name:
-
Micro Rapid Flash Point Tester
-
Function:
-
Coating flash point test, paint flash point test.
-
Usage:
-
Continuously Closed Cup Flashpoint
-
Feature:
-
fast, accurate and convenient, continuous
-
Range:
-
10~250℃ continuously adjustable
-
Heating rate accuracy:
-
5.5℃/min±0.5℃/min
-
Amount of samples:
-
1 ml (ASTM D 6450), 2ml(ASTM D 7094)
-
Storage space:
-
more than 10000 samples
-
Ambient temperature:
-
5~40℃
-
Ambient humidity:
-
≤85%
Quick Details
-
Warranty:
-
1 Year
-
Power:
-
Electronic
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
GOLD
-
Model Number:
-
GD-125
-
Product name:
-
Micro Rapid Flash Point Tester
-
Function:
-
Coating flash point test, paint flash point test.
-
Usage:
-
Continuously Closed Cup Flashpoint
-
Feature:
-
fast, accurate and convenient, continuous
-
Range:
-
10~250℃ continuously adjustable
-
Heating rate accuracy:
-
5.5℃/min±0.5℃/min
-
Amount of samples:
-
1 ml (ASTM D 6450), 2ml(ASTM D 7094)
-
Storage space:
-
more than 10000 samples
-
Ambient temperature:
-
5~40℃
-
Ambient humidity:
-
≤85%
The original manufacturer of ASTM D6450 / D7094 Micro Continuously Closed Cup Flash Point Tester in China, we can also supply other types of flash point teters for different application,such as fuel oil, lubricating oil, solvent oil and other liquids.
>>> Features of Rapid Flash Tester <<<
1.Portable design for field use.
2. There is no open flame in the whole testing process, and there is no sample volatilization and evaporation loss.
3. Continuous closed cup design, automatic explosion detection and air supply control protection, prevent fire and smoke, and have reliable safety.
4. Using Peltier technology, the built-in electric heating and cooling technology can achieve rapid heating and cooling of the sample test, and accurately control the test temperature.
5. High flexibility, almost all flash point test methods can be simulated by this product, only need to modify the control parameters and heating rate, air intake and ignition, etc.
6.The instrument is compatible with USB interface and printer, and realizes various network, computer and LIMS system access through LAN.
>>> Main Parameters of Trace Rapid Flash Point Analyzer <<<
1 |
Range |
10~250℃ continuously adjustable |
2 |
Heating rate accuracy |
5.5℃/min±0.5℃/min |
3 |
Temperature control accuracy |
±0.1℃ |
4 |
Amount of samples |
1 ml (ASTM D 6450), 2ml(ASTM D 7094) |
5 |
Pressure range |
0 KPa - 200 KPa |
6 |
Pressure accuracy |
0.1kPa |
7 |
Display |
7-inch industrial color touch screen |
8 |
Detection |
Thermocouple, precision pressure sensor |
9 |
Storage space |
more than 10000 samples |
10 |
Ambient temperature |
5~40℃ |
11 |
Ambient humidity |
≤85% |
12 |
Power |
300W |
13 |
Dimensions |
300*280*460mm |
14 |
Weight |
20kg |
>>> Advantages of Micro Rapid Flash Point Tester <<<
The Safe Side of Flash Point Testing
In contrast to Pensky Martens instruments the GD-125Micro Rapid Flash Point Tester series does not use an open flame. Instead, 2 pins create an electric arc that is used to ignite the sample inside a closed chamber. Due to the small sample volume (1 ml or 2 ml) and the resulting low oxygen amount within the closed cup, the flame is automatically extinguished after ignition. The pressure increase in the closed cup following the ignition is used for the detection of the flash point. A pressure increase of ≥ 20 kPa is defined as a flash point by the method.
ASTM D6450, D7094 and IP 620 are inherently safe flash point methods eliminating any fire hazard from your lab.
>>> Continuously Closed Cup Flash Point Methods <<<
These modern flash point methods feature an enclosed sample volume which is not opened during the whole measurement procedure. This is possible since the sample cup, containing only 1 or 2ml of sample, is pressed against the oven plate forming a closed volume. The necessary sample temperature sensor, as well as the ignition electrodes, are incorporated directly into the oven plate. During testing the sample volume is heated by the oven plate transferring its heat onto the sample cup and further on to the sample. At each testing temperature a spark is ignited by the electrodes inflaming the vapors above the sample. A flash point is detected if the pressure increase due to the burning vapors inside the chamber is greater than 20 kPa. Any burning vapors are extinguished automatically just a few milliseconds after their ignition due to the significantly small volume of oxygen inside the measurement volume. Therefore using a CCCFP flash point tester eliminates all safety concerns in modern labs.
>>> Packaging &Shipping <<<
Pack aging |
The product will be packed in wooden case, and also can be packed by others ways as your request. |
Both neutral and customized packing are available. |
|
Shipping |
We can ship the goods to you by international express,such as DHL, UPS, TNT and so on. |
And you can choose the appropriate way based on your timeline and budget. Besides, you can choose to use your own shipping agent. |
If you have interested in Portable ASTM D7094 & D6450 Continuously Closed Cup Flash Point Tester with Micro Rapid and Safety, please feel free to contact with me:
City Office: F2501,China Resources Building,Xiejiawan,Jiulongpo District,Chongqing,400050,China
Factory: Technical Building,Loncin Industrial Park,Nanping Eco &Tech Dep Zone,Nan'an District, Chongqing
WhatsApp: +86-15123029636
Phone: +86-15123029636
Web :www.lab-testkit.com