- Product Details
- {{item.text}}
Quick Details
-
Product name:
-
Automatic X-ray Fluorescence Method XRF Sulfur Analyzer
-
Brand:
-
GOLD
-
Standard:
-
ASTM D4294
-
Test item:
-
Oil, petroleum products
-
Power supply:
-
AC 220V±20V, 50 Hz
-
Measuring range:
-
17 ppm to 5%
-
Repeatability (r):
-
<0.02894 (S+0.1691)
-
Reproducibility (R):
-
<0.1215 (S+0.05555)
-
Detection limit:
-
10 ppm
-
Oil sample quantity:
-
3 ml ~ 5ml
Quick Details
-
Warranty:
-
1 year
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
GOLD
-
Product name:
-
Automatic X-ray Fluorescence Method XRF Sulfur Analyzer
-
Brand:
-
GOLD
-
Standard:
-
ASTM D4294
-
Test item:
-
Oil, petroleum products
-
Power supply:
-
AC 220V±20V, 50 Hz
-
Measuring range:
-
17 ppm to 5%
-
Repeatability (r):
-
<0.02894 (S+0.1691)
-
Reproducibility (R):
-
<0.1215 (S+0.05555)
-
Detection limit:
-
10 ppm
-
Oil sample quantity:
-
3 ml ~ 5ml
ASTM D4294 XRF Sulfur Oil Analyzer Testing Instrument
S cope of ASTM D4294
This test method covers the determination of total sulfur in petroleum and petroleum products that are single-phase and either liquid at ambient conditions, liqufiable with moderate heat, or soluble in hydrocarbon solvents. These materials can include diesel fuel, jet fuel, kerosine, other distillate oil, naphtha, residual oil, lubricating base oil, hydraulic oil, crude oil, unleaded gasoline, gasoline-ethanol blends, biodiesel (see Note 2), and similar petroleum products.
Advantages of Sulfur Oil Analyzer
1. The sulfur oil analyzer is suitable to determine the S in Oil refer to ASTM D4294, ISO 8754 and IP336 by ENERGY-DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY.
2. The detection lower limit of sulfur content can reach 0.0017%, which can be widely used in the detection of sulfur content of related oil products with percentage content greater than this index.
3. Few samples are used for testing, about 3ml-5ml, the detection time is fast, about 1min ~ 5min, and the detection result is stable, accurate and reliable.
4. Mechanical and electrical integration microcomputer design, 8-inch wide angle colored touch screen, simple and beautiful interface.
5. With the method of fluorescence intensity ratio analysis, the temperature and air pressure can be automatically corrected, and the C / H ratio can also be corrected.
6. The x ray fluorescence analyzer has the function of automatic diagnosis, automatic judgment of the working state of the instrument and automatic detection of working parameters.
7. The data storage capacity is large, it can store 4096 analysis results, 8192 count measurement data and 10 calibration curves. The stored data can be queried, it also can be uploaded to the computer through RS-232 standard communication port.
8. The working curve is automatically selected by default when the instrument is turned on, without user intervention.
9. The unit of measurement result can be selected, ppm or (m / m)%.
Parameters:
Measuring range |
17 ppm to 5% |
Repeatability (r) |
|
Reproducibility (R) |
|
Detection limit |
10 ppm |
Oil sample quantity |
3 ml ~ 5ml |
Measurement time |
It can be set to 30s or 60s or 90s or 120s or 150s |
It can make measurement automatically for single sample |
Replication times can set 1,2, 3, 5, 10 at random; it will show average value and standard deviation at end of measurement. |
Calibration curve numbers |
It can save 10 calibration curves |
Working condition |
a. Ambient temperature: 5~30℃ |
b. Relative humidity: ≤85% (30 ℃) |
|
Power supply |
AC 220V±20V, 50 Hz; Rated power: 30 W |
Dimension and weight |
460mm*260mm*260mm; 12 kg |