For example: Set the start time to 8:00 The rise up time is performed for 60 min It rises evenly to the set brightness value
within 60 minutes from 8:00 PM, that is, 9 PM to the set brightness val
lamp is on, the brightness should drop to zero before starting the rise. Sunset: End time: End time of lamp luminance drop (set
the same as "start time") Rise down time: End time of lamp luminance decrease Drop evenly to the lamp is off according to the set
rise down time " time; For example: Set the end time to 20:00 The rise down time of 60 minutes drops evenly within 60 minutes from
19:00,60 minutes, when it drops at 19:00, and closes at 20:00; The "ON" means that the feature is enabled; The " OFF function
means that the feature is not enabled; After setting, press "tick" in the top right corner to confirm and exit, or click exit not
to save; When the settings parameters overlap, the pop-up prompts are as follows: Parameter overlap is: end time minus rise down
time must be greater than start time plus rise up time popup prompts if less
- Product Details
- {{item.text}}
Quick Details
-
Product Weight(kg):
-
2
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Koniea
-
Connection Mode:
-
Daisy Chain
-
Lamp Body Material:
-
ABS
-
Support Dimmer:
-
Yes
-
Application:
-
Seed Starting, BLOOM, VEG
-
Working Temperature(℃):
-
-20 - 45
-
Color Rendering Index(Ra):
-
90
-
IP Rating:
-
IP65
Quick Details
-
Warranty(Year):
-
3-Year
-
Type:
-
Remote Control
-
Luminous Efficacy(lm/w):
-
0
-
Product Weight(kg):
-
2
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
Koniea
-
Connection Mode:
-
Daisy Chain
-
Lamp Body Material:
-
ABS
-
Support Dimmer:
-
Yes
-
Application:
-
Seed Starting, BLOOM, VEG
-
Working Temperature(℃):
-
-20 - 45
-
Color Rendering Index(Ra):
-
90
-
IP Rating:
-
IP65
Product Description
13: System Settings button, click to enter the setting interface, as follow
Real-TEMP:Collect temperature in real time; TEMP Derating:Temperature reduction protection, when the collected temperature reaches
the set value, the current open all channel brightness began to press the speed of 1% every 5 minutes to reduce the brightness of
the light, until the temperature returns to 5℃ lower than the set value, began to press the speed of 5 minutes up 1% back to the
original brightness (if the temperature cannot recover is down to 0%); Example: Set the decrease temperature to 32℃. When the
collected temperature reaches 32℃, the brightness starts to decrease until the temperature drops to 27℃;
Over-TEMP:Over-temperature protection, when the collected temperature reaches the set value, all the currently opened channels are
closed until the temperature returns to 5℃ below the set value, returning to the original brightness. Example: Set the descending
temperature to 35℃. When the collected temperature reaches 35℃, turn off the lights until the original brightness is restored when
the temperature drops to 30℃;
the set value, the current open all channel brightness began to press the speed of 1% every 5 minutes to reduce the brightness of
the light, until the temperature returns to 5℃ lower than the set value, began to press the speed of 5 minutes up 1% back to the
original brightness (if the temperature cannot recover is down to 0%); Example: Set the decrease temperature to 32℃. When the
collected temperature reaches 32℃, the brightness starts to decrease until the temperature drops to 27℃;
Over-TEMP:Over-temperature protection, when the collected temperature reaches the set value, all the currently opened channels are
closed until the temperature returns to 5℃ below the set value, returning to the original brightness. Example: Set the descending
temperature to 35℃. When the collected temperature reaches 35℃, turn off the lights until the original brightness is restored when
the temperature drops to 30℃;