- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
UHV
-
Model Number:
-
HTGK-III
-
Product name:
-
Circuit Breaker Analyzer
-
Atmospheric pressure:
-
86~106kpa ℃
-
Time:
-
16000.0ms
-
Speed:
-
20.00m/s
-
Insulation resistance:
-
>2MΩ
-
Current:
-
20.00A
-
Power supply:
-
220V±10% 50Hz±10%
-
Temperature range:
-
-10~45℃
-
Humidity:
-
≤80%RH
-
Size:
-
360*290*280mm ; 6kg
Quick Details
-
Warranty:
-
1 years
-
Power:
-
Electronic
-
Place of Origin:
-
Hubei, China
-
Brand Name:
-
UHV
-
Model Number:
-
HTGK-III
-
Product name:
-
Circuit Breaker Analyzer
-
Atmospheric pressure:
-
86~106kpa ℃
-
Time:
-
16000.0ms
-
Speed:
-
20.00m/s
-
Insulation resistance:
-
>2MΩ
-
Current:
-
20.00A
-
Power supply:
-
220V±10% 50Hz±10%
-
Temperature range:
-
-10~45℃
-
Humidity:
-
≤80%RH
-
Size:
-
360*290*280mm ; 6kg
HTGK Series Circuit Breaker Analyzer
Introduction
HTGK-III takes SCM as core to sample, process and output, intelligent, multi-function, data accurate , strong anti-interference , simple operation, small size, light weight , beautiful appearance , etc. It applies to a variety of indoor, outdoor dynamic characteristics test for less oil, more oil switches, vacuum switches, and SF6 switches.
Features
1. Time: 12 contacts’ fixed opening time and closing time, in-phase same time, out-phase same time.
2. Reclose: close-open, open-close, open-close-open for each breaker; process time: 1 opening time, 1 closing time, 2 closing time, metal short circuit time, no-current time.
3. Springing: closing springing time, springing numbers, springing waveform for each breaker; rebound magnitude for each breaker.
4. Speed: instant opening, closing speed, max speed, time-range characteristic curve.
5. Range: total range, open range, over-range, overriding range, rebound magnitude.
6. Current: opening/closing current of opening/closing coil, current waveform diagram.
7. Action voltage: DC30-250V/20A digital adjustable power circuit breaker, auto finish the breaker low voltage action test, measure the breaker action voltage.
Parameters
Service condition |
Input power |
220V±10% 50Hz±10% |
Atmospheric pressure |
86~ 106kpa ℃ |
|
Temperature |
- 10 ~ 40℃ |
|
Humidity |
less than or equal to 80%RH |
|
Safety Performance |
Insulation resistance |
> 2MΩ |
Dielectric strength |
Power to chassis frequency voltage withstands 1.5KV, 1 min, no flashover and arcing. |
|
Basic parameters |
Time |
Range: 4000.0ms, resolution: 0.1ms
|
Speed |
Range: 20.00m/s, resolution 0.01m/s
|
|
Range |
Vacuum Circuit Breaker: range-50.0mm, resolution-0.1mm, error-1%±1d
|
|
Current |
Range: 20.00A, resolution: 0.01A |
|
Output power |
DC30~ 250V digitally adjustable /20A ( Instantaneous work) |
|
Dimension |
360×280×300mm 3 |
|
Weight |
9kg |