HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker
HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker

HAYA with isolation 10KV outdoor circuit breaker automatic reclosing switch 12kv ZW32-12 vacuum circuit breaker

FOB Reference Price: Get Latest Price
≥1 Pieces
US $225
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Place of Origin:
Zhejiang, China
Brand Name:
HAYA
Model Number:
ZW32-12F
maximum working voltage:
630KA
Rated short close current:
50KA
Type:
Vacuum
Poles Number:
3
Altitude:
<1000m
Ambient temperature:
-40C-+40C
product name:
Vacuum Circuit Breaker
Voltage:
12KV-35KV

Quick Details

Breaking Capacity:
20KA
Rated Voltage:
12KV, 12KV-35KV
Rated Current:
630A, 630A -1250A
Place of Origin:
Zhejiang, China
Brand Name:
HAYA
Model Number:
ZW32-12F
maximum working voltage:
630KA
Rated short close current:
50KA
Type:
Vacuum
Poles Number:
3
Altitude:
<1000m
Ambient temperature:
-40C-+40C
product name:
Vacuum Circuit Breaker
Voltage:
12KV-35KV
ZW32-12 Vacuum Circuit Breaker


ZW32-12 vacuum circuit breaker (below) is an outdoor high-voltage distribution equipment with a rated voltage of 12KV and
three-phase AC 50Hz. ZW32-12 is mainly used for breaking and closing load current, overload current, and short circuit current in
power systems of transmission and transformation lines. Suitable for protection and control in substations and distribution
systems of industrial and mining enterprises, and more suitable for urban and rural power grid construction, renovation, and
frequent operation places.

Instructions for ZW32-12 Outdoor High Voltage Vacuum Circuit Breaker
1. The ZW32-12 outdoor high-voltage vacuum circuit breaker adopts a three-phase pillar structure, which has stable and reliable
breaking performance, no combustion and explosion hazards, maintenance free, small size, light weight, and long service life.
2. The ZW32-12 outdoor high-voltage vacuum circuit breaker adopts a fully enclosed structure with good sealing performance, which
helps improve moisture-proof and anti-condensation performance, and is particularly suitable for use in cold or humid areas.
3. The three-phase pillars and current transformers adopt imported outdoor epoxy resin solid insulation, or indoor epoxy resin
wrapped with organic silicone rubber solid insulation; It has characteristics such as high and low temperature resistance, UV
resistance, and aging resistance.
4. The operating mechanism adopts a miniaturized spring operating mechanism, with low energy storage motor power and low energy
consumption for opening and closing; The mechanism transmission adopts the real motion transmission method, with a small number of
components and high reliability. The operating mechanism is placed in a sealed mechanism box, solving the problem of rusting of
the operating mechanism and improving the reliability of the mechanism.
5. The opening and closing operations of the circuit breaker can be manually or electrically operated, as well as remotely
controlled. It can be matched with intelligent controllers to achieve distribution automation, and can also be combined with
reclosing controllers to form automatic reclosers and segmented devices.
6. Circuit breakers can be equipped with two-phase or three-phase current transformers for overcurrent or short-circuit
protection, and can also provide current acquisition signals to intelligent controllers; According to user requirements, current
transformers for metering can be installed.
7. The ZW32-12 outdoor high-voltage vacuum circuit breaker can be equipped with a three-phase interlocking isolation switch. When
the isolation switch is open, there is a visible fracture, and it has an anti error interlocking device with the circuit breaker
body. The circuit breaker can only be operated when the isolation switch is fully closed or fully opened. It can be connected with
lightning arrester post insulators for easy maintenance.
ZW32-12 Vacuum Circuit Breaker Series Mainstream Models:
Zw32-12, zw32-12FG/630, zw32-12f/630, zw32-12g/630, zw32-12g/630-20, zw32-12g/630-25, zw32-1

Serial number
Order
Unit
Numerical value
1
Rated electric jade
kv
12
2
Rated rate
HZ
50
3
Rated current
A
630
4
Rated short-circuit breaking current
KA
20
5
Rated current
KA
50
6
Rated short time withstand current (4S)
KA
20
7
Rated short-circuit making current (peak value)
KA
50
8
Institutional lifespan
Times
10000
9
Rated current breaking times
Times
10000
10
Rated short-circuit breaking current breaking times
Times
30
11
1min Gongnaiyu (wet)
KV
34
12
(Dry) Interphase, ground to ground/fracture

KV
42/48
13
Lightning impulse withstand current (peak value)
Interphase, ground to ground/new interface
KV
75/85
14
Secondary circuit 1min Gongnaiyu
KV
2
mechanical properties
1
Contact distance
mm
8-10
2
Overtravel
mm
2-3
3
Fractional velocity
ms
1.0-1.4
4
Convergence speed
ms
0.6-0.8
5
Jump time between contacts
ms
≤ 2
6
Center distance between phases
mm
338-342
7
Different phases between three-phase opening and closing
ms
≤ 2
8
Resistance of each phase electrical circuit

<80
9
Resistance of each phase electrical circuit with isolation switch

<150
10
one hundred and fifty
ms
30-60
11
Split time (shunt trip)
ms
20-40
12
Rated power of energy storage machine
w
40
ZW32 Structural characteristics
2.1 The circuit breaker is composed of three-phase pillars and mechanism boxes, with a simple and clear structure. The three-phase
pillars and current transformers are insulated with outdoor epoxy resin solid or silicone rubber, which has advantages such as
high and low temperature resistance, UV resistance, and aging resistance; Adopting a miniaturized spring operating mechanism, the
energy consumption for opening and closing is low. The transmission output of the mechanism adopts the spindle sliding mode,
without torque loss, with fewer opening and closing transmission components and high reliability; The current transformer is
installed on the moving end outgoing line, making maintenance and replacement convenient.
This circuit breaker can be equipped with an isolation switch, three-phase linkage, and has obvious visible fractures when the
isolation switch is open. It has anti error interlocking with the circuit breaker body, making maintenance convenient and safe.
2.2 The high-voltage vacuum circuit breaker equipped with a vacuum arc extinguishing chamber has stable and reliable breaking
performance, and is free from combustion and explosion hazards Features include insurance, safety, maintenance free, small size, light weight (<100kg), and long service life.
2.3 The circuit breaker adopts a fully enclosed structure with good sealing performance, moisture-proof and anti-condensation
properties, and is suitable for use in high-temperature and humid areas.
2.4 The closing and opening of the circuit breaker can be manually and electrically operated, as well as remotely operated. It can
be matched with a controller to achieve distribution automation, and can also be combined with a reclosing controller to form a
reclosing device.
The operating mechanism is novel, simple, reliable in operation, small in size, and has a lifespan of up to 10000 times.
2.6 The installation method of circuit breakers can be single pole or double pole.
3. Installation, Use, and Maintenance
3.1 After unpacking, the insulation cover of the circuit breaker on the column should be checked for damage, and the product
nameplate and certificate of conformity should be checked to ensure they match the actual product.
Before putting the column mounted circuit breaker into operation, it is necessary to carefully check whether the rated voltage and
rated current of each operating element match the actual situation. And conduct testing operations using the closing and opening
methods provided by the mechanism to check whether all indicators are correct.
3.3 The circuit breaker can be erected on a single pole as shown in the figure.
3.4 The circuit breaker on this column, due to its special design structure, ensures that users are free from maintenance for a
long time during use.
3.5 Users are not allowed to replace or use electrical components that are inconsistent with the original model and specifications
36. The staff of the playground have a preliminary understanding of the performance, installation, adjustment, and maintenance of
the mechanism, and provide guidance on operational issues. If necessary, the manufacturer can be notified.
4. Transportation, receipt and storage
41 Transportation
The entire unit must be packed in a sealed packaging box and secured during transportation. During transportation, anti vibration
measures must be taken to prevent overturning or tilting
42 yuan
After receiving the pole mounted circuit breaker, proceed as follows:
421 Check if the packaging is damaged

APP
Post My RFQ
WhatsApp