Products
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For

Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For

FOB Reference Price: Get Latest Price
≥10 Pieces
US $1372
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Brand Name:
Teriwo
Model Number:
QUH-01
Project name:
ultrasonic cutting hemostasis knife system
model:
QUH-01
Power Supply:
Electrical
guarantee:
2 years
after-sale service:
Online technical support
quality guarantee period:
2 years
Quality certification:
ce
Safety standards:
GB15979-2002
Model and size of ultrasonic knife:
14/23/36/45mm

Quick Details

Warranty:
2 years
After-sale Service:
Online technical support
Place of Origin:
Chongqing, China
Brand Name:
Teriwo
Model Number:
QUH-01
Project name:
ultrasonic cutting hemostasis knife system
model:
QUH-01
Power Supply:
Electrical
guarantee:
2 years
after-sale service:
Online technical support
quality guarantee period:
2 years
Quality certification:
ce
Safety standards:
GB15979-2002
Model and size of ultrasonic knife:
14/23/36/45mm
Laparoscop Surgery Ultrasonic Scalpel Generator Surgical Instruments Cutting Hemostasis Ultrasonic Surgical Harmonic Scalpel For
Products Description
ultrasonic cutting hemostasis knife system
The ultrasonic electric energy is converted into mechanical energy of the same frequency through the ultrasonic transducer to generate longitudinal mechanical vibration. The vibration is transmitted to the front end of the cutter head through the guide rod. The vibration of the cutter head produces hemostasis or coagulation and cutting effects on the Gripping tissue. Ultrasound scalpel can be used in clinic: ENT, head and neck surgery, breast surgery, hepatobiliary surgery, thoracic surgery, gastrointestinal surgery, gynecology, urology, etc.

一.Composition of ultrasonic cutting hemostasis knife system

The system is mainly composed of five parts:generator (K500), handle (QUHP35), cutter head (QHS14S, QHS23S and QHS36S), foot switch (QFS - 02 optional) and trolley (C100 optional).

二.Profile

1.Generator The main function of the generator is to provide electrical energy of ultrasonic frequency, and control the output of electrical energy to the handle transducer by activating the foot switch or the handle switch. Set the output energy through the front panel operation of the generator, and observe the working state of the system. Different gears provide different energy. The system generator model is K500.
2.Handle There is an electroacoustic transducer in the handle, which can convert the electrical energy provided by the generator into precise mechanical motion(ultrasonic vibration). The transducer is connected to the ultrasonic horn;The horn amplifies the motion generated by the transducer. The handle receives the electric energy from the generator and transfers it to the cutter head through accurate and controllable mechanical movement. System handle model: QUHP35
3.Cutter head Mechanical motion is transferred from the handle to the tip, while ultrasound energy is transferred to hemostasis or coagulation and cutting of tissue. The tip is a sterile single-use medical device that is disposed of after use and cannot be sterilized for reuse (human market). The tips are sterilized by ethylene oxide or cobalt-60 irradiation at the time of delivery; the irradiation sterilization is valid for four years, beyond the expiration date or if the sterilization package is damaged, the tips should be stopped immediately and scrapped or destroyed. The system can be equipped with QUHS14S, QUHS23S and QUHS36S. Operating frequency of the cutter head: 55.5 k Hz ±1 k Hz.
4. Foot switch Used to start or stop the output of ultrasound energy. The system is equipped with a foot switch model QFS-02, which is optional.
5. Trolley In order to facilitate the movement of the system equipment, the main unit can be placed on the uppermost counter of the cart, the foot switch is placed on the lowermost counter, the handle can be pushed forward to move, and the brake pedal on the rear wheel can be stepped on to prevent the cart from moving by itself when it is not positioned.