- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Shanghai, China
-
Brand Name:
-
PEAK INSTRUMENTS
-
Model Number:
-
E-1000UV201
-
Focal Length:
-
Null
-
Wavelength Range:
-
190-1020nm
-
Display:
-
40*70mm backlit LCD
-
Optical System:
-
Single beam, Holographic Grating (1200 Lines/mm)
-
Spectral Bandwidth:
-
4 nm
-
Wavelength Accuracy:
-
±2nm
-
Wavelength Repeatability:
-
≤1nm
-
Stray light:
-
≤0.15%T@360nm
-
Baseline Flatness:
-
null
-
Noise:
-
null
-
Detector:
-
Solid Silicon Photodiode
-
Light Source:
-
Deuterium/Tungsten Lamp
Quick Details
-
Warranty:
-
3 years
-
Size:
-
44*36*18CM
-
Weight:
-
6.5KG
-
Place of Origin:
-
Shanghai, China
-
Brand Name:
-
PEAK INSTRUMENTS
-
Model Number:
-
E-1000UV201
-
Focal Length:
-
Null
-
Wavelength Range:
-
190-1020nm
-
Display:
-
40*70mm backlit LCD
-
Optical System:
-
Single beam, Holographic Grating (1200 Lines/mm)
-
Spectral Bandwidth:
-
4 nm
-
Wavelength Accuracy:
-
±2nm
-
Wavelength Repeatability:
-
≤1nm
-
Stray light:
-
≤0.15%T@360nm
-
Baseline Flatness:
-
null
-
Noise:
-
null
-
Detector:
-
Solid Silicon Photodiode
-
Light Source:
-
Deuterium/Tungsten Lamp
Product Description
Product Name
|
4nm single beam UV Visible Cheap spectrophotometer
|
Origin
|
China
|
Brand
|
PEAK INSTRUMENTS
|
Model
|
E-1000UV201
|
Function
|
Photometry, quantitative measurement on standalone device.
|
Working Mode
|
T, A, C, F
|
Size
|
44*36*18CM
|
Weight
|
6.5KG
|
Focal length
|
null
|
Wavelength range
|
190-1020nm
|
Display
|
40*70mm backlit LCD
|
Optical System
|
Single beam, Holographic Grating (1200 Lines/mm)
|
Spectral Bandwidth
|
4 nm
|
Wavelength Accuracy
|
±2nm
|
Wavelength Repeatability
|
≤1nm
|
Stray Light
|
≤0.15%T@360nm
|
Detector
|
Solid Silicon Photodiode
|
Light Source
|
Deuterium/Tungsten Lamp
|
Our Advantages
Quality
|
1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
|
|
Delivery Time
|
1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
|
|
Technical Support
|
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online or site training in our factory.
3. We can have video conference at any time.
|
|
Aftersales Support
|
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
|
|
Warranty Time
|
One year and extendable
|
|
Our product advantages are as follws(for high end models):
|
|

1.
7 inch color LCD screen
(button models) can show more parameters

2.
Silicone buttons
with much longer life span and easier to be operated

2.
7 inch capacitive touch screen
and user friendly interface

4.
Standard USB ports
for data transfer and PC software connection.
5.
More functions
for basic models
6.
Stable system
with microcomputer processing
7.
Automatic 8 position
1 cm cell holder(optional)
8.
Long path cell holder
can holde 1-10cm cuvettes(optional)
9.
Tube rack
for tubes with 16mm diameters(optional for all models)
10.
Film cell holder
(optional for all models)
11.
Automatic sampler/sipper system
(optional)
12.
PC software, thermal printer,
etc.
Why Choose Us
1. Positive comments from our
Italian
client
2. Good review from our customer in
Italy
3. Great comments from
Syria
client
4.
UAE
customer is satified with our pH meter
5.
Argentina
customer is happy with our pH meters
6.
Turkey
user is satisfied with its performance of spectrophotometer
7.
Spain
customer is very happy with our fast service and professional technical support
8.
Indian
client is happy with our great support
9.
Peru
customer likes our spectrophotometer very much
10.
Salvador
customer has good comments on our pH meter
11.
South Africa
customer is happy with the accuracy of our spectrophotometer and pH meter
12. Customer in
Poland
said our products are very good
Certifications
CE
ISO 9001 and ISO14001 are also available
CE ANNEX
Product process
1.Install main board
|
2.Connect the cables for main board
|
3.Install W1 lamp and D2 lamp
|
4.Assemble sample chamber and cell holder
|
5.Install power board
|
6.Assemble monochromator
|
7.Upload software
|
8.Adjust and test W1 lamp and D2 lamp
|
9.System test
|
10.Housing installation and final calibration
|
Customer Photos
Customer visit and training
Visit cutomers and have a training
Customer from Brazil
Visit and train customers in Chile
Training
Customer from Argentina
Clients from Korea
Distributor from Thailand
FAQ
Q: What areas and applications can it be used?
|
|
|
|
|
||||
A: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.
|
|
|
|
|
||||
Q: Does it need any installation
|
|
|
|
|
||||
A: The installation is very simple, just need to connect it to power supply and turn it on, then you can use it.
|
|
|
|
|
||||
Q: What standard accessories are included?
|
|
|
|
|
||||
A: Main unit, 1cm cell holder(4 positions for single beam and 2 positions for double beam), 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), one USB with user manual and power cable.
|
|
|
|
|
||||
Q: Is PC software included?
|
|
|
|
|
||||
A: The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.
|
|
|
|
|
||||
Q: Why the reading is red and reach its maximum value 3.00Abs?
|
|
|
|
|
||||
A: Probably you use the glass cuvette in UV range.
|
|
|
|
|
||||
Q: Why the wavelength calibration or self checking fail?
|
|
|
|
|
||||
A: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
|
|
|
|
|
||||
Q: Why is the reading is not as accurate as before?
|
|
|
|
|
||||
A: Do the wavelength calibration before testing or restore the device to its default factory settings.
|
|
|
|
|
||||
Q: Why PC software can not be installed successfully?
|
|
|
|
|
||||
A: Close your anti-virus software on the computer and do it again.
|
|
|
|
|
||||
Q: Why the software can not be connected successfully?
|
|
|
|
|
||||
A: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.
|
|
|
|
|
||||
Q: Can the data transferred to USB or PC?
|
|
|
|
|
||||
A: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.
|
|
|
|
|
||||
Q: Why the Abs value is negative(lower than zero).
|
|
|
|
|
||||
A: Do the blanking or change the reference sample.
|
|
|
|
|
Exhibition
Analytica in Germany
Pittcon in USA
ArabLab in Dubai
IndiaLabExpo in India
Analytica Lab Africa
Analitica Latin America in Sao Paulo, Brazil
Hot Searches