- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
TUNKIA
-
Model Number:
-
TM4300B
-
Accuracy:
-
Class 1/Class 2
-
Measurement Range:
-
0~2000 μT
-
Frequency Range:
-
DC~400 Hz
-
Unit switch:
-
μT, mG
-
Resolution:
-
10 nT
-
Temperature Coefficient:
-
± 0.1 %/°C
-
Display:
-
LCD, 5 Digit
-
Power Supply:
-
4000 mAh lithium battery, USB charging
-
Weight:
-
About 500 g
-
Communication Interface:
-
USB Interface
Quick Details
-
Warranty:
-
1 year
-
Power:
-
Electronic
-
Place of Origin:
-
Hunan, China
-
Brand Name:
-
TUNKIA
-
Model Number:
-
TM4300B
-
Accuracy:
-
Class 1/Class 2
-
Measurement Range:
-
0~2000 μT
-
Frequency Range:
-
DC~400 Hz
-
Unit switch:
-
μT, mG
-
Resolution:
-
10 nT
-
Temperature Coefficient:
-
± 0.1 %/°C
-
Display:
-
LCD, 5 Digit
-
Power Supply:
-
4000 mAh lithium battery, USB charging
-
Weight:
-
About 500 g
-
Communication Interface:
-
USB Interface
T M4300 B Handheld Triaxial Fluxgate Magnetomete r
TM4 3 00B is a portable, multi-function meter that measures low magnetic field, e quipped with high sensitivity , h igh linearity, l ow drift triaxial fluxgate sensor, which can measure low magnetic field accurately.
- Range: 0~ 2000 μT.
- Various of probes are optional.
- Accuracy : class 1 or 2 .
- Unit switch: μT, mG.
- +/- polarity display.
- Relative measurement mode.
- Max . hold function.
- USB interface.
- Measuring XYZ component, vector synthetic value.
- A larm function of exceeding the upper / lower limit .
- D isplay support backlight and battery power.
- Magnetic measurement data storage.
- L ithium battery, remaining power display.
- Measuring low magnetic field.
- Geological prospecting.
- Fragmentation processing, security check.
- Fault location, research experiment.
- Magnetic shielding evaluation.
- Calibrating low magnetic field sources.
- Detecting magnetic resonance meter.
- Detecting electron microscope.
- Detecting Magnetic field drift.
P robe [1] ( μ T ) |
Resolution ( n T ) |
Accuracy |
N oise @ 1Hz |
Temperature Coefficient ( % /°C ) |
|
Class 2 |
Class 1 |
||||
10 0 |
10 |
± 2% |
± 1% |
< 20 nT rms |
± 0.1 |
50 0 |
10 |
± 2% |
± 1% |
< 20 nT rms |
± 0.1 |
100 0 |
100 |
± 2% |
± 1% |
< 20 nT rms |
± 0.1 |
2 00 0 |
100 |
± 2% |
± 1% |
< 20 nT rms |
± 0.1 |
Note [1] : The corresponding probe is selected according to the measurement of range. |
- XYZ Range : 0~ ± 2000 μT
- R Range : 0~ ± 3464 μT
- Display Digits : 5-digit s display.
- Frequency Range : DC ~ 400 Hz
- Linearity : ± 0. 5 %
P ower Supply |
4000 mAh lithium battery , USB c harging |
Temperature Performance |
Operating temperature : 0°C~ 45°C S torage temperature : -20°C~ 70°C |
H umidity Performance |
W orking humidity :2 0%~ 8 0 % R·H , Non-condensing S torage humidity : < 85 % R·H , Non-condensing |
Weight |
About 5 0 0 g |
Interface |
F luxgate probe input interface , USB interface |
Dimensions |
90 mm (W) × 40 mm (D) × 165 mm (H) |
P robe Dimensions |
20 mm ( L ) × 1 4 mm (W) × 1 2 mm (H) |
Probe Selection