- Product Details
- {{item.text}}
Quick Details
-
Type:
-
Air Source Heat Pump
-
Place of Origin:
-
Shandong, China
-
Brand Name:
-
Haier or OEM
-
Model Number:
-
HPM-Nd2
-
Product Name:
-
EVI DC Inverter R290 Air To Water Heat Pump For Heating And Cooling
-
Keyword:
-
Air To Water Heat Pump
-
Function:
-
House Heating Cooling Hot Water
-
Refrigerant:
-
R290
-
Heating Capacity:
-
8~16kw
-
Compressor:
-
EVI DC Inverter Compressor
-
Ambient Temperature:
-
Minus 30~43 Degree
-
Power Supply:
-
220-240V/50Hz/1ph
-
Noise Level:
-
≤51dB(A)
-
Feature:
-
Easy Install
Quick Details
-
Warranty:
-
3 years
-
Application:
-
Car, RV, Outdoor, Hotel, Garage, Commercial, Household
-
Power Source:
-
Electric, Gas, Solar
-
Type:
-
Air Source Heat Pump
-
Place of Origin:
-
Shandong, China
-
Brand Name:
-
Haier or OEM
-
Model Number:
-
HPM-Nd2
-
Product Name:
-
EVI DC Inverter R290 Air To Water Heat Pump For Heating And Cooling
-
Keyword:
-
Air To Water Heat Pump
-
Function:
-
House Heating Cooling Hot Water
-
Refrigerant:
-
R290
-
Heating Capacity:
-
8~16kw
-
Compressor:
-
EVI DC Inverter Compressor
-
Ambient Temperature:
-
Minus 30~43 Degree
-
Power Supply:
-
220-240V/50Hz/1ph
-
Noise Level:
-
≤51dB(A)
-
Feature:
-
Easy Install
Product Categories
Products Description
New Energy WIFI ERP A+++ Domestic R290 Monoblock Air To Hot Water DC Inverter EVI Air Source Heat Pump For Heating And Cooling
|
|
|
|
|
|
|
|
|||||||
Model
|
|
|
HPM
08-Nd2
|
HPM
10-Nd2
|
HPM
12-Nd2
|
HPM
14-Nd2
|
HPM
16-Nd2
|
|||||||
Intended use of the units
|
|
|
Low and medium temperature application
|
|
|
|
|
|||||||
Power supply
|
|
V / Ph / Hz
|
220-240/1/50
|
|
|
|
|
|||||||
(AT7/6, WT30/35)
|
Capacity
|
kW
|
8
|
10
|
12
|
14
|
16
|
|||||||
|
Rated power input
|
kW
|
1.62
|
2.08
|
2.45
|
2.74
|
3.25
|
|||||||
|
COP
|
kW/kW
|
4.95
|
4.8
|
4.9
|
5.11
|
4.92
|
|||||||
(AT7/6, WT47/55)
|
Capacity
|
kW
|
8
|
10
|
12
|
14
|
16
|
|||||||
Heating (AT7/6, WT47/55)
|
Rated power input
|
kW
|
2.42
|
3.03
|
3.43
|
4.24
|
5.0
|
|||||||
|
COP
|
kW/kW
|
3.3
|
3.3
|
3.5
|
3.3
|
3.2
|
|||||||
(AT35, WT23/18)
|
Capacity
|
kW
|
8
|
10
|
11.4
|
14
|
16
|
|||||||
|
Rated power input
|
kW
|
1.63
|
2.15
|
2.78
|
2.74
|
3.33
|
|||||||
|
COP
|
kW/kW
|
4.9
|
4.65
|
4.1
|
5.11
|
4.8
|
|||||||
(AT35, WT12/7)
|
Capacity
|
kW
|
8
|
10
|
11.4
|
14
|
16
|
|||||||
|
Rated power input
|
kW
|
2.5
|
3.33
|
4.07
|
4.52
|
5.51
|
|||||||
|
COP
|
kW/kW
|
3.2
|
3.0
|
2.8
|
3.1
|
2.9
|
|||||||
SCOP
|
Average climate
|
35°C
|
4.9
|
4.9
|
4.9
|
5.2
|
4.9
|
|||||||
|
Average climate
|
55°C
|
3.85
|
3.85
|
3.85
|
3.9
|
3.9
|
|||||||
Season space heating energy efficiency class
|
Average climate
|
35°C
|
A+++
|
A+++
|
A+++
|
A+++
|
A+++
|
|||||||
|
Average climate
|
55°C
|
A+++
|
A+++
|
A+++
|
A+++
|
A+++
|
|||||||
|
Fan coil application
|
7°C
|
4.5
|
4.5
|
4.5
|
5.1
|
5.1
|
|||||||
|
Cooling floor application
|
18°C
|
6.3
|
6.5
|
6.2
|
7.0
|
7.0
|
|||||||
|
Type
|
-
|
R290
|
|
|
|
|
|||||||
|
Charge
|
kg
|
1.3
|
1.3
|
1.35
|
1.95
|
1.95
|
|||||||
E-Heater Backup
|
|
kW
|
3.0
|
3.0
|
3.0
|
6.0
|
6.0
|
|||||||
Sound Pressure(1m)
|
|
dB
|
45
|
49
|
51
|
51
|
51
|
|||||||
|
Rated water flow
|
m3/h
|
1.38
|
1.72
|
2.06
|
2.41
|
2.75
|
|||||||
|
Total water head
|
m
|
12.5
|
12.3
|
12
|
11.5
|
11.1
|
|||||||
|
Available water head
|
m
|
9
|
8.8
|
8.5
|
8
|
7.6
|
|||||||
Maximum working pressure of refrigerant
|
|
Mpa
|
0.85/3.2
|
|
|
|
|
|||||||
Water side safety valve
|
|
Mpa
|
0.6
|
0.6
|
0.6
|
0.6
|
0.6
|
|||||||
Water proof grade
|
|
/
|
IPX4
|
|
|
|
|
|||||||
Water side connection
|
|
in
|
1
|
1
|
1
|
1
|
1
|
|||||||
Net dimension
|
W*D*H
|
mm
|
1312x470x990
|
|
1312x470x1370
|
|
|
|||||||
Package dimension
|
W*D*H
|
mm
|
1362x567x1167
|
|
1362x567x1560
|
|
|
|||||||
|
Cooling
|
°C
|
10-48
|
|
|
|
|
|||||||
|
Heating
|
°C
|
-30-35
|
|
|
|
|
|||||||
|
DHW
|
°C
|
-30-43
|
|
|
|
|
|||||||
|
Cooling
|
°C
|
5-25
|
|
|
|
|
|||||||
|
Heating
|
°C
|
24-75
|
|
|
|
|
|||||||
|
DHW
|
°C
|
30-60
|
|
|
|
|
Product Features
I
HEATING, COOLING AND DOMESTIC HOT WATER IN ONE SYSTEM
Haier ProWarm* is an integrated system that provides everything your home needs: heating, cooling, and domestic hot water. It is also the ideal alternative for traditional gas or fuel oil heating, allowing you to enjoy delightfully warm and perfectly hot water throughout the year.
Heating in winter
Haier ProWarm* can deliver whole house heating during cold seasons to enhance your comfort.
Cooling in summer
Haier ProWarm* quickly cools down and maintains comfortable during hot seasons.
Domestic hot water all the year
Providing all your hot water needs throughout the year, such as bathing and washing etc.
I COP 5.1, SAVE UP TO 80% ENERGY
High efficiency means low energy costs, Haier ProWarm* can greatly reduce energy bills for users.
Heating system efficiency is measured by the Coefficient of Performance (COP). Thanks to the use of high efficiency inverter compressor, the COP is as high as 5.1.
Haier ProWarm* can extract free heat from the surrounding air to provide efficient heating, cooling, and domestic hot water for your home, saving up to 80% energy.
I
FOUR TECHNOLOGIES FOR ENERGY-SAVING PERFORMANCE
The technologically advanced Haier ProWarm* takes a step ahead in efficiency and sustainability.
Multiple Anti-freezing Protection
By implementing multiple anti-freezing technologies, such as water pump circulation, system circulation, and chassis heating, the temperatures of the main unit and pipes are automatically monitored. The heat pump will automatically heat to 15°C when the ambient temperature is lower than 2°C and the water temperature is lower than 7°C. This feature prevents the system from freezing.
Water pump circulation
When the ambient temperature is less than or equal to the anti-freezing temperature, the circulating water pump starts running.
System circulation
Automatically monitors the temperatures of the main unit and pipes to prevent system from freezing.
Chassis heating
Optimize the evaporator flow path, heat the chassis to prevent frosting at the bottom, and simultaneously optimize the air outlet to reduce air flow resistance, resulting in stronger heat exchange and more even defrosting.
Hot Searches