- Product Details
- {{item.text}}
Quick Details
-
Size of burner:
-
2.2*1.4*3.8 m
-
Size of filling entrance:
-
900*1100 mm
-
Air-blower:
-
1.1 kw
-
Auxiliary machine power:
-
0.22 kw
-
Auxiliary machine oil consumption:
-
7-14 kg/h
-
Re-burning machine power:
-
0.37 kw
-
Re-burning machine oil consumption:
-
10-20 kg/h
-
Running voltage:
-
380/ 220V
Quick Details
-
Place of Origin:
-
Shandong, China
-
Product name:
-
Medical hazardous solide waste incinerator
-
Burning ability:
-
30-50 kg/time(3-6 times per day)
-
Size of burner:
-
2.2*1.4*3.8 m
-
Size of filling entrance:
-
900*1100 mm
-
Air-blower:
-
1.1 kw
-
Auxiliary machine power:
-
0.22 kw
-
Auxiliary machine oil consumption:
-
7-14 kg/h
-
Re-burning machine power:
-
0.37 kw
-
Re-burning machine oil consumption:
-
10-20 kg/h
-
Running voltage:
-
380/ 220V
Product Description
Incinerator burn waste type
Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, etc
No.
|
Equipment name
|
Specification
|
Qty
|
1
|
First combustion chamber
|
A3 steel, refractory brick, refractory coating
|
1set
|
2
|
Electronic control box
|
|
1set
|
4
|
Secondary burning chamber
|
A3 steel, refractory brick, refractory coating
|
1set
|
5
|
Mixing burning chamber
|
A3 steel, refractory brick, refractory coating
|
1set
|
6
|
Auxiliary burner
|
Italy Baltur burner
|
1set
|
7
|
Flue gas purification chamber
|
A3 steel, refractory brick, refractory coating
|
1set
|
8
|
Oil storage tank
|
steel plate
|
1set
|
7
|
Flue gas purification chamber
|
A3 steel, refractory brick, refractory coating
|
1set
|
8
|
Oil storage tank
|
steel plate
|
1pc
|
9
|
Ash rake
|
Length: 1.0m
|
1pc
|
10
|
Ventilate pipe
|
A3 steel pipe
|
1set
|
11
|
Chimney
|
A3 iron , height 9m
|
1set
|
12
|
Thermoelectric couple
|
Resist high temperature 1200℃
|
1set
|
Usual Model Flue gas emission standard
Flue gas blackness:1 grade(Ringelmann black degree)
Smoke:100 mg/m3
Carbon monoxide:100mg/m3
Sulfur dioxide:400mg/m3
Hydrogen chloride:100mg/m3
NOX Nitrous Oxides:500mg/m3
Total Enclosed Solid Waste Incinerator Flue gas emission standard
Smoke blackness:Ringerman level 1
Flue gas:80mg/m3
CO:80mg/m3
SO2: 300mg/m3
HF:7.0mg/m3
HCL:70mg/m3
Oxides of nitrogen (NO2):500mg/m3
Mercury and its compounds (Hg): 0.1mg/m3
Cadmium and its compounds (Cod): 0.1mg/m3
Model list
Model item
|
LDF-20
|
LDF-30
|
LDF-50
|
LDF-100
|
LDF-150
|
LDF-300
|
LDF-500
|
Burning Capacity
(kg/time)
3-6 times/day |
10-20
|
20-30
|
30-50
|
50-100
|
100-150
|
200-300
|
300-400
|
Burn chamber size (m)(L*H*B)
|
1.6*1.2*1.7
|
1.45*0.9*1.75
|
1.8*1.15*3
|
1.8m*1.4*3.4
|
2*1.4*3.5
|
2.2*1.4*3.8
|
3*2*4.8
|
Feed door size (mm)
|
380*480
|
480*600
|
620*800
|
520*720
|
760*960
|
900*1100
|
1080*1280
|
Chimney
(mm)
|
Ø280
(OD) |
Ø280
(OD) |
Ø280
(OD) |
Ø300
(OD) |
Ø300
(OD) |
Ø400
(OD) |
Ø460
(OD) |
Air-blower (KW)
|
0.25
|
0.37
|
0.37
|
0.5
|
0.5
|
1.1
|
1.1/0.55
|
Auxiliary machine power(kw)
|
0.11
|
0.11
|
0.11
|
0.11
|
0.11
|
0.22
|
0.22
|
Auxiliary machine oil consumption
(kg/h)
|
4-6
|
4-6
|
4-10
|
4-10
|
4-10
|
7-14
|
7-14
|
Re-burning machine power(kw)
|
0.11
|
0.11
|
0.11
|
0.22
|
0.22
|
0.37
|
0.37
|
Re-burning machine oil consumption
(kg/h)
|
4-6
|
4-6
|
4-10
|
7-14
|
7-14
|
10-20
|
15-26
|
Running voltage(V)
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
Running voltage(V)
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
380/ 220
|
Product packaging