- Product Details
- {{item.text}}
Quick Details
-
Model Number:
-
INC-CA13
-
Place of Origin:
-
Guangdong, China
-
Wavelength:
-
470nm
-
Incubator Temperature:
-
37±0.2℃
-
Quality control:
-
Auto draw the QC figure
-
Reagent:
-
Open reagent system
-
Reagent volume:
-
≤40μL
-
Repeatability:
-
CV≤5%
-
Temperature:
-
10℃~30℃
-
Humidity:
-
20%RH-80%RH
-
Voltage:
-
AC 85V~264V
-
Power:
-
≤80W
Quick Details
-
Warranty:
-
1 Year
-
After-sale Service:
-
Online technical support
-
Brand Name:
-
INNOCOM
-
Model Number:
-
INC-CA13
-
Place of Origin:
-
Guangdong, China
-
Wavelength:
-
470nm
-
Incubator Temperature:
-
37±0.2℃
-
Quality control:
-
Auto draw the QC figure
-
Reagent:
-
Open reagent system
-
Reagent volume:
-
≤40μL
-
Repeatability:
-
CV≤5%
-
Temperature:
-
10℃~30℃
-
Humidity:
-
20%RH-80%RH
-
Voltage:
-
AC 85V~264V
-
Power:
-
≤80W
Hospital portable blood coagulometer analyzer coagulometer blood coagulation analyzer
Specifications
Test Method: Dispersion light nephelometric analysis
Test Principle: The highest point on first order differentiation, Percentage analysis
Zero point correction: Auto track the zero point, eliminate the effect of sample and reagent
Wavelength: 470nm
Light Source: Cold Lamp with high brightness and long lifetime
Detector: Unique dispersion light detector with high sensitivity and repeatability, immunized the effect
on result of jaundice,hemolysis,chyle and turbidity on plasma
Test Channel: 4 channels,each channel is independent, one or more same or different items can be test
Simultaneously
Incubator: Provide 28 incubators for reagent and sample
Incubator Temperature:37±0.2℃
Measure trigger: Auto trigger the measurement through configured pipette
Item modify: easy to add or edit items, easy to set the items parameters
Calibration: single-point calibration; multipoint calibration; auto store and match with calibration curve
Quality control: Auto draw the QC figure
Reagent: Open reagent system
Reagent volume: ≤40μL
Sample volume: ≤40μL
Memory: Save more than 10000 samples results, and auto recover the results when power is off during
Working condition
Repeatability: CV≤5%
Calculative item: S,%,PTR,INR,Fib can be get through PT, This leads to lower the cost of reagent
Printer: Inner thermal printer,can be connected to external printer
Information edit: easy to input and edit the detail information of patients
Interface: RS-232 serial port,can be connected to external printer and computer
Working Environment: Temperature:10℃~30℃;Humidity: 20%RH-80%RH
Voltage: AC 85V~264V,Auto adapt according to the input voltage
Power : ≤80W
Quality System: Recognized by CE TUV and CMD
Test Items
PT, APTT, TT, Fib, RepT, VT, AT-Ⅲ, Protein-S, Protein-C, LA, Hep