- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Liaoning, China
-
Brand Name:
-
AOLONG
-
Model Number:
-
AL-NP-5010A
-
Focal Length:
-
None
-
Wavelength Range:
-
0.063---0.071nm
-
Product name:
-
Energy Dispersive X-ray Fluorescence Spectrometer
-
Name:
-
xrf analyzer
-
Resolution:
-
< 145eV
-
Rohs:
-
Cd,Pb,Cr,Hg,Br
-
Application:
-
Non-ferrous Metals
-
Operating Temperature:
-
10-35℃
-
Element measuring range:
-
Na(11)-U(92)
-
Sample type:
-
block, powder, liquid
Quick Details
-
Warranty:
-
1 years
-
Size:
-
620*580*500
-
Weight:
-
43KG
-
Place of Origin:
-
Liaoning, China
-
Brand Name:
-
AOLONG
-
Model Number:
-
AL-NP-5010A
-
Focal Length:
-
None
-
Wavelength Range:
-
0.063---0.071nm
-
Product name:
-
Energy Dispersive X-ray Fluorescence Spectrometer
-
Name:
-
xrf analyzer
-
Resolution:
-
< 145eV
-
Rohs:
-
Cd,Pb,Cr,Hg,Br
-
Application:
-
Non-ferrous Metals
-
Operating Temperature:
-
10-35℃
-
Element measuring range:
-
Na(11)-U(92)
-
Sample type:
-
block, powder, liquid
Basic principle of XRF analysis
The electron orbital potential energy of the various elements is different from each other excitation is different from each other,i.e.,each element emits x-rays with the specific energy of the atom of that element,which represents the characteristics of the element and is therefore called the characteristic X-ray of the element. The characteristic X-ray of each element has its specific energy, and the X-ray detected with certain energy can determine the existence of this element in the material sample.
Applications widely
●
Electronics, plastics, metal materials: various electronic components, hardware, plastic materials and products, circuit board etc.
●
Paper and paper materials: raw materials, various paper, toner, ink, etc.
●
Petroleum, coal: petroleum, lubricating oil, heavy oil, polymer, coal, coke, etc.
●
Ceramics, cement: ceramics, refractory materials, rocks, glass, cement, cement raw materials and raw materials, clinker, limestone, clay, etc.
●
Agriculture, food: soil, pesticide residues, fertilizer, plants, various food and so on.
●
Non-ferrous metals: copper alloys, aluminum alloys, lead alloys, zinc alloys, magnesium alloys, titanium alloys, precious metals, etc.
●
lron and steel: pig iron, cast iron, stainless steel, low alloy steel, high alloy steel, special steel, ferroalloy, iron ore, slag, electroplating solution, casting sand, etc
●
Chemical industry: inorganic organics and products, cosmetics, detergents, rubber, toners, catalysts, coatings, pigments, drugs, chemical fibers, etc.
●
Environment: all kinds of waste, industrial waste, atmospheric dust, industrial waste water, sea water, river water, etc.
●
Biological science: organisms. auxiliaries, etc.
Main component and technial parameters
● The detection limit of harmful elements Cd, Pd, Cr, Hg and Br is restricted according to ROHS instruction
Detection limit (Cd, Pd, Cr, Hg, Br): 2ppm
●
Si(PIN) or SDD detector
The resolution of detector is one of the main indexes to evaluate the performance of energy dispersive XRF spectrometer.
Resolution< 145eV (The lower the resolution, the higher the sensitivity.)
Detection limit (Cd, Pd, Cr, Hg, Br): 2ppm
Counting rate >1000/S
Crystal area > 15m㎡
Beryllium window thickness = 0.025mm
Detector power< 1.2W
●
Multi-channel analyzer
Number of channels: 2048 channels
●
Power controller
System power control: +5 VDC at 250 mA(1.2 W)
Constant cooling control: 400 VDC
●
X ray tube
The X-ray tube, specially treated with embedded lead inside is shielded in full range, leaving only the side window for the x ray outlet. The canned insulating oil is used for high voltage insulation and cooling, 0.005 inch Beryllium window,rated consumption power 50W, rated power 50kV. Designed service life >15000h.
●
High voltage generator
Input: 85 ~ 265VAC, 47 ~ 63Hz, Power factor correction.1kV ~ 5kV comply to UL85 ~250VAC input standard
Voltage variation: 0.01% of output voltage from no load to full load
Current variation: 0 ~rated power, 0.01% of output current
Ripple: Peak - peak of output voltage 0.25%
Temperature variation:voltage or current setting, 0.01%/oC
Stability: 0.05%/8h after warming-up for half an hour
Technical parameters
Model
|
|
Al - NP - 5010A
|
|
Anylysis principle
|
|
Energy dispersive X-ray fluorescence analysis
|
|
Element measuring range
|
|
Any element from Na(11)~U(92)
|
|
Min. measuring limit
|
|
Cd/Hg/Br/Cr/Pb ≤ 2ppm
|
|
Sample shape
|
|
Arbitrary size, any irregular shape
|
|
Sanple type
|
|
Plastic/metal/film/powder/liquid etc
|
|
X ray tube
|
Target material
|
Mo
|
|
|
Tube voltage
|
5-50KV
|
|
|
Tube current
|
1-1000μA
|
|
Sample exposure diameter
|
|
2, 5, 8mm
|
|
Detector
|
|
Si-PIN or SDD detector, high speed pulse height analysis system
|
|
High voltage generator
|
|
Special HV genetator for X fluorescence
|
|
ADC
|
|
2048 channels
|
|
Filter
|
|
6filters are automatically selected and converted
|
|
Sample observation
|
|
200 * color CCD camera
|
|
Analysis software
|
|
Patented software products, free upgrade for life
|
|
Analysis method
|
|
Theoretical α coefficient method, basic parameter method, empirical coefficient method
|
|
Analysis time
|
|
30-900 seconds, adjustable
|
|
Operating system software
|
|
WINDOWS XP
|
|
Data processing system
|
Host
|
PC business model
|
|
|
CPU
|
≥ 2.8G
|
|
|
Memory
|
≥ 2G
|
|
|
CD-ROM
|
8*DVD
|
|
|
Hard disk
|
≥ 500G
|
|
|
Display
|
22″ or 24″ LCD display
|
|
Working enviroment
|
|
Temperature 10-35 ℃, humidity 30-90% RH
|