- Product Details
- {{item.text}}
Quick Details
-
Norminal diameter(mm):
-
15DN or 20DN
-
Material:
-
Aluminum, chrome plating
-
Glass bulb color:
-
Orange, red, yellow, green, blue, purple
-
Bulb:
-
3mm or 5mm
-
Flow Rate:
-
80±4 or 115±6
-
Temperature rating:
-
57,68, 79,93,141,182 degree
-
Type:
-
Pendent, upright, sidewall types of fire sprinkler
-
Response:
-
Quick response
-
Certificates:
-
ISO and CCC
-
Usage:
-
Rescu system
Quick Details
-
Place of Origin:
-
Fujian, China
-
Brand Name:
-
MINSHAN
-
Model Number:
-
MS-FS-146
-
Norminal diameter(mm):
-
15DN or 20DN
-
Material:
-
Aluminum, chrome plating
-
Glass bulb color:
-
Orange, red, yellow, green, blue, purple
-
Bulb:
-
3mm or 5mm
-
Flow Rate:
-
80±4 or 115±6
-
Temperature rating:
-
57,68, 79,93,141,182 degree
-
Type:
-
Pendent, upright, sidewall types of fire sprinkler
-
Response:
-
Quick response
-
Certificates:
-
ISO and CCC
-
Usage:
-
Rescu system
foam water sprinkler fire sprinkler hidden camera
-
fire sprinkler
-
lawn sprinkler
-
fire sprinkler hidden camera
Foam water sprinkler fire sprinkler hidden camera with ISO, CCC Certificates
Each closed-head sprinkler is held closed by either a heat-sensitive glass bulb (see below) or a two-part metal link held together with fusible alloy such as Wood's metal and other alloys with similar compositions.The glass bulb or link applies pressure to a pipe cap which acts as a plug prevents water from flowing until the ambient temperature around the sprinkler reaches the design activation temperature of the individual sprinkler. Each sprinkler activates independently when the predetermined heat level is reached, the number of sprinklers that operate is limited to only those near the fire, thereby maximizing the available water pressure over the point of fire origin.
The bulb breaks which results to the thermal expansion of the liquid inside the bulb. The time it takes before a bulb breaks is dependent on the temperature. Below the design temperature, it does not break, and above the design temperature, it takes less time for higher temperatures. The response time is expressed as a response time index (RTI), which typically has values between 35 and 250 m½s½, where a low value indicates a fast response. Under standard testing procedures (135 °C air at a velocity of 2.5 m/s), a 68 °C sprinkler bulb will break within 7 to 33 seconds, depending on the RTI.[13] The RTI can also be specified in imperial units, where 1 ft½s½ is equivalent to 0.55 m½s½. The sensitivity of a sprinkler can be negatively affected if the thermal element has been painted.
;Characteristics and Functions | |
Model | ESFR |
Material | Aluminum, chrome plating |
Type | Upright type of fire sprinkler |
Norminal diameter(mm) | 15DN or 20DN |
Connecting thread | R1/2 or R3/4 |
Glass bulb color | Red |
Temperature rating | 68 °C |
Flow Rate | 80±4 or 115±6 |
Bulb | 3mm or 5mm |
Response | quick response |
; ;Basic Parameters of Fire Sprinkler | ||||
Model | Norminal Diameter | Thread | Flow Rate | Style |
T-ZSTP | DN15 | R1/2 | 80±4 | Upright/Pendent |
DN20 | R3/4 | 115±6 | ||
T-ZSTX | DN15 | R1/2 | 80±4 | Pendent |
DN20 | R3/4 | 115±6 | ||
T-ZSTZ | DN15 | R1/2 | 80±4 | Upright |
DN20 | R3/4 | 115±6 | ||
T-ZSTBS | DN15 | R1/2 | 80±4 | Horizontal Sidewall |
DN20 | R3/4 | 115±6 | ||
ZSTDY | DN15 | R1/2 | 80±4 | Pendent |
DN20 | R3/4 | 115±6 |
Nozzle Rated Temp | Max Ambient Temp | Glass Ball Color |
57 °C | 27 °C | Orange |
68 °C | 38 °C | Red |
79 °C | 49 °C | Yellow |
93 °C | 63 °C | Green |
141 °C | 111 °C | Blue |
182 °C | 152 °C |
Purple
|
Outstanding Service:
Fast feedback: we promise to reply your inquiry within 24hours
Positive cooperation with your esteemed company
Good suggestions to your choice if necessary with our own rich experience
OEM accepted
Your visited to factory welcomed!
Q: Are you a factory or trading company?
We are factory specialized on fire fighting equipment.
Q: Can I get a sample?
For certainly, please contact us for detail.
Q: What's the terms of the payment?
T/T, L/C, Western Union, MoneyGram, etc.