- Product Details
- {{item.text}}
Quick Details
-
Voltage:
-
220V/380V
-
Dimension(L*W*H):
-
750*600*1130 mm
-
Weight:
-
70 KG
-
Power:
-
2500
-
Working Temperature Range:
-
5 degrees Celsius
-
Compressor:
-
"Mitsubishi" / "Copeland"
-
Application:
-
New energy
-
Product name:
-
Water Cooled Chiller
-
Refrigerant:
-
R22/R407C
-
Cooling type:
-
Air cooling
-
Cooling method:
-
Single-stage refrigeration / multi-machine parallel
-
Cooling capacity:
-
2.5kw/5kw/7kw/10kw/15kw
-
Marketing Type:
-
New Product 2024
-
Color:
-
White
Quick Details
-
Condition:
-
New
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
T&HLS
-
Voltage:
-
220V/380V
-
Dimension(L*W*H):
-
750*600*1130 mm
-
Weight:
-
70 KG
-
Power:
-
2500
-
Working Temperature Range:
-
5 degrees Celsius
-
Compressor:
-
"Mitsubishi" / "Copeland"
-
Application:
-
New energy
-
Product name:
-
Water Cooled Chiller
-
Refrigerant:
-
R22/R407C
-
Cooling type:
-
Air cooling
-
Cooling method:
-
Single-stage refrigeration / multi-machine parallel
-
Cooling capacity:
-
2.5kw/5kw/7kw/10kw/15kw
-
Marketing Type:
-
New Product 2024
-
Color:
-
White
Product Description


Main Features of lab circulating chiller
1) Controllable temperature and flow, to provide a thermostatic environment
2) Equipped with a inside cooling bath for direct cooling materials inside
3) Digital display of temperature makes the temperature setting simple and flexibly Efficient and secure temperature conversion
4) Safe in operation, easy to move around with casters with lock
5) A variety of fault alarm (over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm)
6) Closed cycle pipeline design to prevent circulating water from pollution and extend the lifetime of circulation liquid.
7) Circulating system adopts SUS304 stainless steel material and macromole anti-corrosion material, which can prevent rust,corrosion and low temperature liquid pollution
2) Equipped with a inside cooling bath for direct cooling materials inside
3) Digital display of temperature makes the temperature setting simple and flexibly Efficient and secure temperature conversion
4) Safe in operation, easy to move around with casters with lock
5) A variety of fault alarm (over temperature alarm, sensor alarm, high pressure alarm, compressor overheat alarm, liquid level alarm)
6) Closed cycle pipeline design to prevent circulating water from pollution and extend the lifetime of circulation liquid.
7) Circulating system adopts SUS304 stainless steel material and macromole anti-corrosion material, which can prevent rust,corrosion and low temperature liquid pollution
Specification
Cooled Water Circulation System
|
|
|
|
|
|
|
|
|
||||||||
Model
|
TWL-25MF
|
TWL-50MF
|
TWL-70MF
|
TWL-100MF
|
TWL-150MF
|
TWL-260MF
|
TWL-300MF
|
TWL-500MF
|
||||||||
Outer Size
|
D80xW45xH130
|
D90Xw50xH130
|
D110xW60xH176
|
D120xW60xH180
|
D120xW75xH180
|
D120xW80xH180
|
D150xW85xH180
|
D220xW110xH180
|
||||||||
Medium Temperature Range
|
5℃~35℃
|
|
|
|
|
|
|
|
||||||||
Temperature Control
|
High-precision controller to control the outlet temperature (can record set temperature, measured temperature data and curve)
|
|
|
|
|
|
|
|
||||||||
Fluctuation
|
A: 0.5°C/B: 1.0°C/C: 2.0°C (under no load or constant load)
|
|
|
|
|
|
|
|
||||||||
Volume Control Type
|
Manual
|
|
|
|
|
|
|
|
||||||||
Cooling Capacity
|
2.5KW
|
5 KW
|
7 KW
|
10 KW
|
15 KW
|
25 KW
|
30KW
|
50 KW
|
||||||||
|
2150Kcal/h
|
4300Kcal/h
|
6020Kcal/h
|
8600Kcal/h
|
12900Kcal/h
|
21500Kcal/h
|
25800 Kcal/h
|
43000 Kcal/h
|
||||||||
Water Tank Volume
|
20L
|
35L
|
40L
|
50L
|
60L
|
100L
|
200L
|
300L
|
||||||||
Flow output
|
2~20L/min
|
3~25L/min
|
5~40L/min
|
5~55L/min
|
5~70L/min
|
110L/min
|
200L/min
|
250L/min
|
||||||||
Working Noise
|
≤72 dB(A)
|
|
|
|
|
|
|
|
||||||||
Working Power
|
~1.5KW
|
~1.9KW
|
~2.65KW
|
~3.8KW
|
~5.35KW
|
~8.6KW
|
~11.3KW
|
~17.9KW
|
||||||||
QTY of Compressor
|
1 set
|
35L
|
40L
|
1 set / 2 set
|
|
|
|
60L
|
||||||||
Cooling Method
|
Single-stage refrigeration / multi-machine parallel
|
3~25L/min
|
5~40L/min
|
5~55L/min
|
|
|
|
5~70L/min
|
||||||||
Compressor
|
"Mitsubishi" / "Copeland"
|
~2.35KW
|
~2.85KW
|
~3.5KW
|
|
|
|
~4.35KW
|
||||||||
Refrigerant
|
R22 (optional R407C DuPont environmentally friendly refrigerant)
|
DN20
|
DN20
|
DN20
|
|
|
|
DN25
|
||||||||
N.W.
|
136kg
|
175kg
|
210kg
|
265kg
|
320kg
|
350kg
|
410kg
|
530kg
|
||||||||
Cooling Type
|
Air-cooled (optional water-cooled plate replacement, the cost remains unchanged)
|
|
|
|
|
|
|
|
||||||||
Heater
|
In-Line/Submerged
|
|
|
|
|
|
|
|
||||||||
Controller
|
HLS-U760W
|
|
|
|
|
|
|
|
||||||||
Connection Size
|
DN15
|
DN20
|
DN20
|
DN20
|
DN25
|
DN32
|
DN40
|
DN40
|
||||||||
Power Supply
|
AC220V 50HZ( optional AC240V 60HZ)
|
|
AC380V 50HZ(optional AC440V 60HZ)
|
|
|
|
|
|
||||||||
Safety Device
|
1. Compressor pressure protection
2. Phase sequence/phase loss protection 3. Mechanical over-temperature protection 4. Electronic over-temperature protection 5. Water flow protection device 6. Liquid level protection device 7. Antifreeze protection device |
|
|
|
|
|
|
|
||||||||
Explanation
|
Take TPWL-25LAM as an example, TPWL is a precision cooling water system produced by Harris ; the number 25 means the cooling capacity
is 2.5KW; the letter L means the standard low temperature type (the high temperature type is H); the letter A is the water temperature control fluctuation The temperature is 0.5℃; the letter M indicates that the water flow is manually adjusted. |
|
|
|
|
|
|
|
Detail advantage

All improtant components are imported from Europe ,the United States,and Japan ............
Product Type
Type 1
Type 2
Type 3
Type 4
Type 5
Type 6
Packing & Delivery
Packaging: polywood case for temperature humidity incubator
Hot Searches