- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
sulphur testing equipment
-
Model Number:
-
GD-4294 sulphur testing equipment
-
Measurement range:
-
17ppm to 5%
-
Repeatability (r):
-
<0.02894(S+0.1691)
-
Reproducibility (R):
-
<0.1215(S+0.05555)
-
Detection limit:
-
10 ppm
-
Oil sample quantity:
-
3 ml
-
Measurement time:
-
it can be set to 30s or 60s or 90s or 120s or 150s
-
Ambient temperature:
-
5~30℃
-
Product name:
-
GD-4294 ASTM D4294 Sulfur Content Measuring Instrument
-
Certification:
-
pcoc
Quick Details
-
Warranty:
-
1 Year, 1 Year
-
Power:
-
Electronic
-
Place of Origin:
-
Chongqing, China
-
Brand Name:
-
sulphur testing equipment
-
Model Number:
-
GD-4294 sulphur testing equipment
-
Measurement range:
-
17ppm to 5%
-
Repeatability (r):
-
<0.02894(S+0.1691)
-
Reproducibility (R):
-
<0.1215(S+0.05555)
-
Detection limit:
-
10 ppm
-
Oil sample quantity:
-
3 ml
-
Measurement time:
-
it can be set to 30s or 60s or 90s or 120s or 150s
-
Ambient temperature:
-
5~30℃
-
Product name:
-
GD-4294 ASTM D4294 Sulfur Content Measuring Instrument
-
Certification:
-
pcoc
GD-4294 ASTM D4294 Sulfur Content Measuring Instrument and Sulphur Testing Equipment by X-ray Fluorescence Method
Introduction:
GD-4294 ASTM D4294 Sulfur Content Measuring Instrument is specially designed to determine sulfur content in the petroleum products. Adopts energy-dispersive principle, and with electrical, mechanical and microprocessor integration design, so it is rapid and accurate. Sulphur Testing Equipment can meet the requirements of National Standard GB/T 17040 and GB/T11140 on repeatability and reproducibility, and it can also meet requirements of ASTM D4294-03 on these indexes. Sulphur Testing Equipment provides a measure to determine sulfur content during petroleum or petrochemical production process.
Specifications:
(1) Measurement range: 50 ppm to 5%;
(2) Repeatability (r): <0.02894(S+0.1691) ;
(3) Reproducibility (R): <0.1215(S+0.05555) ;
(4) Detection limit: 10 ppm;
(5) Oil sample quantity: 3 ml ( it is equal to sample depth of 3 mm ~ 4 mm);
(6) Measurement time: it can be set to 30s or 60 s or 90s or 120 s or 15 0s ;
(7) It can make determination automatically for single sample. R ep lica tion times can set 1, 2, 3, 5, 10 at random; it will show average value and standard deviation at end of measurement.
(8) Calibration curve numbers: it can save 10 calibration curves.
(9) Working condition:
a. Ambient temperature: 5~ 3 0℃;
b. Relative humidity: ≤ 85% (30 ℃);
(10) Power supply : AC 220V±20V , 50 Hz/60Hz; Rated power: 50 W;
(11) Size and weight: 46 0 mm* 260 mm* 260 mm ; 12 kg;