Quick Details
-
Brand Name:
-
Qunlong
-
Model Number:
-
MDZY-KLKHF
-
Test Principle:
-
Karl Fischer Coulomb method (electrolysis method)
-
Measuring range:
-
1μg-300mg
-
Measurement Accuracy:
-
3μg (10μg--100μg H2O)
-
Measurement Resolution:
-
0.1μg H2O
-
Relative Water Content Range:
-
1ppm-100%
-
Electrolytic Current:
-
0-500mA
-
Moisture Resolution:
-
0.001ppm/0.001%
-
Concentration Unit:
-
%,ppm,mg/kg
-
Storing data:
-
500pcs
Quick Details
-
Warranty:
-
1 years
-
Power:
-
Electronic
-
Place of Origin:
-
Fujian, China
-
Brand Name:
-
Qunlong
-
Model Number:
-
MDZY-KLKHF
-
Test Principle:
-
Karl Fischer Coulomb method (electrolysis method)
-
Measuring range:
-
1μg-300mg
-
Measurement Accuracy:
-
3μg (10μg--100μg H2O)
-
Measurement Resolution:
-
0.1μg H2O
-
Relative Water Content Range:
-
1ppm-100%
-
Electrolytic Current:
-
0-500mA
-
Moisture Resolution:
-
0.001ppm/0.001%
-
Concentration Unit:
-
%,ppm,mg/kg
-
Storing data:
-
500pcs
MDZY-KLKHF Karl Fischer moisture meter adopts a unique needle design, which can realize carrier gas input and water vapor output in one operation. At the same time, due to the new gas circuit design, the instrument can realize the transmission of water vapor with a very small flow rate. Moreover, only the sample bottle needs to be replaced each time the sample is injected, and the operation is simple and convenient.
Application Field
1,Trace moisture detection, detection accuracy can reach ppm level. It is very suitable for industries that have high requirements for moisture detection, such as lithium batteries, plastics, and petrochemicals.
2,For product moisture detection with limited sample size, the minimum 20mg can be tested (the sampling weight is determined according to the moisture content of the sample). It is suitable for industries with expensive samples and limited product quantities, such as medicine.
3,The products that produces various volatiles upon heating. These products are mainly concentrated in the chemical industry.
Technical Parameter
Model | MDZY-KLKHF |
Test Principle | Karl Fischer Coulomb method (electrolysis method) |
Measuring speed | 2.8mg H2O /min(Max.) |
Measuring range | 1μg-300mg |
Measurement Accuracy |
3μg (10μg--100μg H2O);
≤0.3% (water content> 100μg H2O); (Excluding injection errors) |
Measurement Resolution | 0.1μg H2O |
Relative Water Content Range | 1ppm-100% |
Electrolytic Current | 0-500mA, adjustablle |
Moisture Concentration Resolution | 0.001ppm |
Concentration Unit | %,ppm,mg/kg |
Stirring Speed | Stepless touch adjustment |
Drift value, blank value deducted | Deducted automatically |
Special function |
Automatic drift compensation,
environment and background water automatic deduction, fault self-detection prompt |
Display and operation | Color touch screen |
Sample Number | Users can set sample number freely |
Storing data | 500pcs |
Print Function | Built-in thermal printer, paper width 58mm |
Print Content | Display different contents according to the user's measurement formula and measurement results |
Calendar/Time | Display and print out the current time, date, detection time |
End Point Indication | Screen prompt; Print out; Sound warning; Terminal light indication; |
Environmental Conditions | Temperature 2℃-50℃, humidity<90% |
Power | ≤50W |
Size | 350*300*170mm |
Voltage | 220V,50Hz,150w |
Weight | 4kg |
Product Name | Karl heating furnace |
Analysis of temperature control | 1℃ |
Temperature range | 40-300℃ |
Heating rate | 30℃/min(40-200℃); |
10℃/min(200-300℃) | |
Cooling rate | 10℃/min |
Flow range | 0-100ml/min (0.1Mpa),(0-300ml/min can also be selected) |
Flow accuracy | 1ml/min |
Vial size | 10ml(5ml,20ml optional) |
Thermostatic pipeline | 12V,5W |
Carrier gas input interface | 3.2mm corrosion-resistant pipeline |
Carrier gas system | External high-purity air generator (can be connected to nitrogen, oxygen and other gas sources) |
Ambient Temperature | 5-40℃ |
Environment Humidity | <65%, the drier the humidity, the more stable the instrument |
Size | 350*250*220mm |
Voltage | 220V,50Hz,150W |
Product Features
1,The combination of high-precision coulometric moisture analyzer and karl heating furnace can detect water at a minimum of 3μg, and the accuracy can reach ppm level;
2,The maximum temperature is 300℃, which can meet the detection of most samples. Air flow 0-100ml, can be adjusted freely, suitable for products with various moisture release rates.
3,Hollow core gas needle injection technology and gas delivery management design with heating function, so that the water with zero dead volume will not condense. While simplifying the operation steps, it also improves the accuracy and repeatability of the instrument.
4,Headspace sampling technology. During the test, a new round of measurement can be started just by replacing the sample bottle, without transferring the sample, the operation is simple, and the measurement efficiency is greatly improved. At the same time, the sample bottle is always kept sealed, and the sample will not be disturbed by moisture in the air, which ensures the accuracy of the measurement results. In addition, because a new vial is used for each measurement, cross-contamination between samples does not occur.
5,Headspace sampling technology. Only the gas enters the reaction cup and does not contaminate the reaction cup and electrolysis electrodes.
6,High-definition capacitive touch screen, the menu is concise and clear, the operation is convenient and fast, and the measurement parameters can be displayed in real time.
7,5 kinds of measurement methods and 8 kinds of calculation formulas are available for selection, which is convenient for the detection of various samples. Custom units are: %, ppm, mg/kg, etc.;
8,The system detects the moisture in the environment in real time, and will accurately deduct the drift. At the same time, the real-time dynamic impedance method is used to determine the end point of the titration to ensure more accurate measurement results.
9,The test operation is simple and convenient. Just set the parameters such as temperature and flow, put the sample into the prepared sample bottle, put the sample bottle in the heater, then stick the transfer needle into the silicone pad of the sample bottle, and click on the instrument to start the measurement.