- Product Details
- {{item.text}}
Quick Details
-
Flow of Gas Sample:
-
300ml/min
-
Way of Sampling:
-
Absorb Pump
-
Working Life of Sensor:
-
>2 Years
-
Operating Life of Battery:
-
Continuous 8 hours
Quick Details
-
Place of Origin:
-
Beijing, China
-
Brand Name:
-
CPR
-
Model Number:
-
CPR-KA
-
Flow of Gas Sample:
-
300ml/min
-
Way of Sampling:
-
Absorb Pump
-
Working Life of Sensor:
-
>2 Years
-
Operating Life of Battery:
-
Continuous 8 hours
CPR-KA Mobile Air Quality Monitoring System
CPR-KA Air Quality Monitoring System consists of SO2 analyzer, NOX (NO2/NO)
analyzer, O3 analyzer, CO analyzer, PM10 analyzer, VOC analyzer, THC analyzer and meteorological multi parameter monitor, etc.
The basic equipment only has the function to detect SO2, NO2, PM10 or PM2.5 three parameters, but can extend to detect other gases by the customers’ requirement.
CPR-KA Air Quality Monitoring System is developed with international electronic
technique and network communication based on the fixed electric potential electro-analysis principle,monitoring of polluted gas, light scattering principle and β ray method.
Features
A. Rational design, easy to be used as a portable or automatic continuous online monitoring instrument;
B. Easy to monitor all Gas parameters and PM10 whose value will be shown on the screen as well;
C. Automatic sampling and analyzing continuously when it used as back pack instrument;
D. High sensitivity sensor, rapidly response, high resolution ratio, Detecting inferior limit
can be achieved ppb;
E. Measured concentration value can be realized through switchover among mg/m3,ppm,ppb with trends graphs;
F. Display with graph screen, directly shows all kinds of inspection data, graphs and machine status, providing friendly man-machine talk interface;
G. SCM( singlechip microcomputer) mixed with internet communication along with the function of data storage, providing convenient way of data inquiry, also can transfer the
data to computer by USB, its daily average value, monthly average value, and pollute index can be auto calculated by upper computer software, printed in different kinds of
graphic data.
H. Lithium battery or outer A.C., if power-off, the battery can be worked for 8 hours continuously.
I. Stable, high-accuracy, easy to use and maintain protection when power-off.
Technical Parameters
Application Field:
Urban atmospheric environment monitoring, Corporate environmental monitoring, Non-organizational pollution gas emission monitoring, Environmental assessment monitoring.