- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
WellBlue
-
Model Number:
-
L-RO500
-
Power (W):
-
24W
-
Voltage (V):
-
220V
-
Item No.:
-
L-RO650A
-
Capacity:
-
400G 600GPD
-
Operation temperature:
-
5~45C
-
Feed water TDS biggest limit:
-
≤1000PPm
-
Pressure tank:
-
3.2G Steel Tank
-
Water purification method:
-
PP+CTO+RO+T33 (T33 could be changed into alkaline mineral filter)
-
Product size:
-
52*26*50cm
-
Feed water pressure:
-
1~4bar (0.1~0.4Mpa)
-
Diaphragm Booster Pump with Adaptor:
-
110V/220V, 50/60Hz
-
Pump:
-
400G Booster Pump
Quick Details
-
Warranty:
-
1 Year
-
Application:
-
Hotel, Household
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
WellBlue
-
Model Number:
-
L-RO500
-
Power (W):
-
24W
-
Voltage (V):
-
220V
-
Item No.:
-
L-RO650A
-
Capacity:
-
400G 600GPD
-
Operation temperature:
-
5~45C
-
Feed water TDS biggest limit:
-
≤1000PPm
-
Pressure tank:
-
3.2G Steel Tank
-
Water purification method:
-
PP+CTO+RO+T33 (T33 could be changed into alkaline mineral filter)
-
Product size:
-
52*26*50cm
-
Feed water pressure:
-
1~4bar (0.1~0.4Mpa)
-
Diaphragm Booster Pump with Adaptor:
-
110V/220V, 50/60Hz
-
Pump:
-
400G Booster Pump
Specification
Name
|
Tankless 400/600G Reverse osmosis system
( TDS & filter lifespan display)
|
Model Number
|
L-RO650A
|
Voltage (V)
|
110-220V
|
After-sales Service Provided
|
Free spare parts
|
RO Filter Life
|
24 Months
|
Function
|
Hot Water Function, self-cleaning
|
Filtration Stages
|
4
|
Operation temperature
|
5~45C
|
Feed water TDS biggest limit
|
≤1000PPm
|
Feed water source
|
Tap water or rural water
|
Water purification method
|
PP+CTO+RO+T33 (T33 could be changed into alkaline mineral filter)
|
Product size
|
52*26*50cm
|
Feed water pressure
|
1~4bar (0.1~0.4Mpa)
|
Product Description
5-stage Reverse Osmosis Water Purifier PP+GAC+CTO+RO+T33
(
Stage 1)
5 Micron PP Sediment Filter(PP Filter) With only 5 micron filter precision, It is effective in removing dirt, rust and
sand particles.
sand particles.
(
Stage 2)
Block Carbon Filter ( CTO Filter) It takes out 99% of the chlorine and
organic chemicals. It provides reduction of taste, odor, and color.
organic chemicals. It provides reduction of taste, odor, and color.
(
Stage 3)
Reverse Osmosis Membrane Filter(RO Filter) A thin
film composite (TFC) high quality membrane that processes 75 gallons per day. It remove the following hard water contaminants that
may be present in your water: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium.
( Stage 4) Post Carbon filter(T33 Filter):This carbon post filter removes objectionable tastes and odors to enhance the quality of your drinking water.We are using NSF approved post carbon to guarantee the taste of water. T33 filter could be changed into Mineral alkaline filter
film composite (TFC) high quality membrane that processes 75 gallons per day. It remove the following hard water contaminants that
may be present in your water: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium.
( Stage 4) Post Carbon filter(T33 Filter):This carbon post filter removes objectionable tastes and odors to enhance the quality of your drinking water.We are using NSF approved post carbon to guarantee the taste of water. T33 filter could be changed into Mineral alkaline filter
If you want add
uv and alkaline filter
all can provide
Under-sink RO installation
Including machine
Accessories
5 filters-PP, GAC, CTO, 75G RO, T33
Faucet
fitting
1/4inch
Waste water clip
Wrench
Adaptor
1.2 m Tube
Installation method
Water inlet valve connect with 3-way water inlet valve
Close the inlet water valve, unscrew the connection hoses from the inlet water valve; Take out the 3-way valve from the accessories box, then connect the female thread end with inlet water valve, and connect the connection hoses with male thread end of 3-way water valve. (Figure 1 left)
Connect water inlet ball valve with tap water inlet of RO system by PE pipe. According to position and
distance, cut the PE pipe into suitable length.
RO membrane installation
A) unscrew the RO membrane shell with a matched wrench, and take down the cap.
B) Find out the end with two black 0-ring of RO membrane first, then insert it into the membrane shell
totally, and screw the cap on it tigtly. (Figure 2)
Maintenance
In order to make sure each filter catridge filter performance, we had better to replace each inside filter
cartridge on regular time.
PP fiter service life: 3-6 months(based on the local water quality)
Activated carbon filter(GAC) service life: 6 months
RO membrane filter service life: 12 months
Post carbon filter(T33) service life: 6 months
Our product catalog
(Click to get it)
|
|
|
|
|
||||
|
|
|
|
|||||
Amazon hot sale
|
|
|
||||||
|
|
|
||||||
|
|
|
|
|||||
New product listing
|
|
|
||||||
|
|
|
|
|||||
Popular main tweets
|
|
|
||||||
|
|
|
||||||
|
|
|
|
|||||
|
|
|
|
|||||
|
||||||||
|
|
|
|
|||||
|
|
|
|
|||||
|
|
|
||||||
|
|
|
|
|||||
AliExpress Hot Deals
|
|
|
||||||
|
|
|
|
|||||
|
|
|||||||
|
|
|
|
|||||
|
||||||||
|
|
|
|
Hot Searches