DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
NEWGOER
-
Model Number:
-
DSC-300C
-
Model:
-
DSC-300C
-
DSC Range:
-
0~± 800mW
-
Temperature Range:
-
-40 ~ 600℃
-
Heating Rate:
-
0.1~100℃/min
-
Temperature Resolution:
-
0.01℃
-
Temperature Fluctuation:
-
±0.01℃
-
DSC Sensitivity:
-
0.01mW
-
Product name:
-
DSC Differential Scanning Calorimeter
-
Function:
-
glass transition temperature, crystallization, phase transition, OIT
Quick Details
-
Warranty:
-
1 year, 24 Months
-
Power:
-
Electronic
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
NEWGOER
-
Model Number:
-
DSC-300C
-
Model:
-
DSC-300C
-
DSC Range:
-
0~± 800mW
-
Temperature Range:
-
-40 ~ 600℃
-
Heating Rate:
-
0.1~100℃/min
-
Temperature Resolution:
-
0.01℃
-
Temperature Fluctuation:
-
±0.01℃
-
DSC Sensitivity:
-
0.01mW
-
Product name:
-
DSC Differential Scanning Calorimeter
-
Function:
-
glass transition temperature, crystallization, phase transition, OIT
Product Description
|
|
|
|
|
|
|
ASTM D 3895, ASTM D 3417, ASTM D 3418, ISO 11357-6 ETC... |
Model Selection
Model
|
DSC-100
|
DSC-100L
|
DSC-300
|
DSC-300L
|
DSC-300C
|
|||||
Temperature Range
|
RT ~ 800℃
|
-100 ~ 800℃
|
RT ~ 550℃
|
-150 ~ 600℃
|
-40 ~ 600℃
|
|||||
DSC Range
|
0~± 600mW
|
0~± 600mW
|
0~± 600mW
|
0~± 600mW
|
0~± 800mW
|
|||||
Cooling Method
|
Air Cooled
|
Liquid Nitrogen Cooled
|
Air Cooled
|
Liquid Nitrogen
Cooled
|
Mechanical
Cooled
|
|||||
Scanning Method
|
Heating Scan
|
Heating Scan
|
Heating Scan + Cooling Scan
|
|
|
|||||
More Specifications and Details please Contact Us
|
|
|
|
|
|
-
-
-
Product Description--
-
Differential Scanning Calorimeter
Features of DSC-300C Differential Scanning Calorimeter
1. The industrial-grade 7-inch touch screen displays rich information.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.
6. Mechanical cooling via low temperature thermostatic bath, better controlled with good linear curve. It can be reused to save costs than liquid nitrogrn.
2. Brand-new metal furnace body structure, with better baseline and higher accuracy. The heating adopts indirect conduction method, which has high uniformity and stability, reduces pulse radiation, and is better than traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, supports self-recovery connection function.
4. Automatically switch the two-channel atmosphere flow, fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.
6. Mechanical cooling via low temperature thermostatic bath, better controlled with good linear curve. It can be reused to save costs than liquid nitrogrn.
Differential Scanning Calorimetry Machine Oxidation Induction Time (OIT) Melting Point DSC Differential Scanning Calorimeter
Details Images
The Differential Scanning Calorimeter DSC refers to in the temperature control program and a certain atmosphere, measuring the temperature difference between the sample and the reference material is proportional to the rate of heat flow through the thermal plate instrument.
Product Usage
Melting point is transition temperature of the material from the liquid crystal phase; the thermal analysis measured the most common one physical data. The measurement accuracy and thermodynamic equilibrium temperature error is up to ± 1 ℃ or so. ICTA recommended method is currently used to measure the melting of a solid material endothermic peak.
Glass is a substance into a glass-like amorphous body (glassy) process; glassy state is a state between liquid and solid. In this aspect there is no crystal structure. DSC determination of the glass transition temperature Tg is based on this nature that polymer at the glass transition temperature, its heat capacity will increase. In the DSC curve, and its performance: when through the glass transition temperature, baseline to the endothermic direction.
Related Products
Packing&Shipping
We have professional packing teams and shipping forwarder to pack and deliver your products!
Packing:
1. Out packing:Standard export wooden case.
2. Inner packing:With careful stretch film wrap product, hard wood board+ strong bandage to fix corners.
3. Checking teams: Specialized staff to inspect and classified your goods.
Shipping:
You can specify other shipping methods such as Airmail, FEDEX or DHL. We shall let you know about the shipping cost after receipt
ofyour order. It's more preferable for you to provide us with your own FEDEX/DHL account number so that the delivery charge can be
charged directly from your account.
Packing:
1. Out packing:Standard export wooden case.
2. Inner packing:With careful stretch film wrap product, hard wood board+ strong bandage to fix corners.
3. Checking teams: Specialized staff to inspect and classified your goods.
Shipping:
You can specify other shipping methods such as Airmail, FEDEX or DHL. We shall let you know about the shipping cost after receipt
ofyour order. It's more preferable for you to provide us with your own FEDEX/DHL account number so that the delivery charge can be
charged directly from your account.
Company Introduction
NEWGOER though 20 years of continuous development, our company has established the main products line of Universal strength testing machines for tension, compression, flexure, and shear etc. Environmental testing chambers and Cell phone, Computer and 3C Electronics testing machines, Package and paper test equipment, Plastic and Rubber Test Equipment, Leather and Shoes Testing Machine and so on! Our equipment is used in over 80 countries worldwide and supported by a network of offices and approved agencies. Our products are used in all industries and educational sectors and we have an enviable reputation for innovation, quality product and excellent customer support !
FAQ
1.Are your company a trading one or a factory ?
Factory + trade (integration), 20 years focusing on test instruments field, 6 years exporting experience. OEM is also acceptable for us.
2.How to choose the most suitable products?
Our professional team will give you the best suggestion as long as you tell us what kind of test you need to do and the required specification.
3.What’s the delivery term?
At most of time, we have stock in the factory. If there is no stock, normally, the delivery time is 15-20 working days after deposit receipt. If you are in urgent need, we can consider making special arrangement for you.
4.Do you accept customization service?
Yes, of course, we can not only offer standard machines, but also customized machines according to your request. Don’t hesitate to tell us your requirement, we will try our best to meet your needs.
5.Can we visit your factory before order?
Yes, we warmly welcome and sincerely invite you or your team to visit our factory, we will help to arrange hotel and pick up you from airport.
Factory + trade (integration), 20 years focusing on test instruments field, 6 years exporting experience. OEM is also acceptable for us.
2.How to choose the most suitable products?
Our professional team will give you the best suggestion as long as you tell us what kind of test you need to do and the required specification.
3.What’s the delivery term?
At most of time, we have stock in the factory. If there is no stock, normally, the delivery time is 15-20 working days after deposit receipt. If you are in urgent need, we can consider making special arrangement for you.
4.Do you accept customization service?
Yes, of course, we can not only offer standard machines, but also customized machines according to your request. Don’t hesitate to tell us your requirement, we will try our best to meet your needs.
5.Can we visit your factory before order?
Yes, we warmly welcome and sincerely invite you or your team to visit our factory, we will help to arrange hotel and pick up you from airport.
Contact Us
Hot Searches