- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
suntree
-
Model Number:
-
HD11N
-
Max. Current:
-
200A
-
Product name:
-
Knife Switch
-
Type:
-
Manual
-
Rated current:
-
16A to 200A
-
Rated voltage:
-
400V/500V/690V
-
Size:
-
8KV
-
Rated impulse withstand voltage (KV):
-
3P/4P
-
Pole:
-
3P/4P
-
Certification:
-
TUV/CE/IEC/ISO
Quick Details
-
Whether the smart:
-
NO
-
Max. Voltage:
-
690V
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
suntree
-
Model Number:
-
HD11N
-
Max. Current:
-
200A
-
Product name:
-
Knife Switch
-
Type:
-
Manual
-
Rated current:
-
16A to 200A
-
Rated voltage:
-
400V/500V/690V
-
Size:
-
8KV
-
Rated impulse withstand voltage (KV):
-
3P/4P
-
Pole:
-
3P/4P
-
Certification:
-
TUV/CE/IEC/ISO




item
|
value
|
Certification
|
TUV/CE/IEC/ISO
|
Whether the smart
|
No
|
Place of Origin
|
China
|
|
Zhejiang
|
Brand Name
|
suntree
|
Model Number
|
HD11N
|
Max. Current
|
200A
|
Max. Voltage
|
690V
|
Product name
|
Knife Switch
|
Type
|
Manual
|
Rated current
|
16A to 200A
|
Rated voltage
|
400V/500V/690V
|
Size
|
8KV
|
Rated impulse withstand voltage (KV)
|
3P/4P
|
Pole
|
3P/4P
|
Scope of application
HD11N series knife switch, suitable for AC 50Hz 400/500/690V, rated service current up to 200A, for PV grid-connected box and
other complete sets of power distribution equipment, as a power and load isolation switch, and with visual contact position and
disconnection point, to ensure the circuit and equipment maintenance and operator safety use.
HD11N series knife switch, suitable for AC 50Hz 400/500/690V, rated service current up to 200A, for PV grid-connected box and
other complete sets of power distribution equipment, as a power and load isolation switch, and with visual contact position and
disconnection point, to ensure the circuit and equipment maintenance and operator safety use.
Service environment
1.The altitude of the installation site should not exceed 2000 m; if it does, the capacity should be derating appropriately.
2. The temperature of the surrounding medium should not be higher than +55 °C and not lower than -5 °C and the average value at 24
hours should not exceed 35 °C (except for special orders).
3.The relative air humidity at the installation site should not exceed 50% at a max. temperature of +55°C. Higher relative
humidity levels are possible at lower temperatures, e.g., up to 90% at 20°C. Special actions should be taken for occasional
condensation due to changes in temperature.
4.The relative humidity of the air in the humid tropics should not exceed 95 % at +25°C.
5. It should be installed in a place free from rain and snow; free from explosion hazards and free from conductive dust and
sufficient corrosion and damage to metal.
1.The altitude of the installation site should not exceed 2000 m; if it does, the capacity should be derating appropriately.
2. The temperature of the surrounding medium should not be higher than +55 °C and not lower than -5 °C and the average value at 24
hours should not exceed 35 °C (except for special orders).
3.The relative air humidity at the installation site should not exceed 50% at a max. temperature of +55°C. Higher relative
humidity levels are possible at lower temperatures, e.g., up to 90% at 20°C. Special actions should be taken for occasional
condensation due to changes in temperature.
4.The relative humidity of the air in the humid tropics should not exceed 95 % at +25°C.
5. It should be installed in a place free from rain and snow; free from explosion hazards and free from conductive dust and
sufficient corrosion and damage to metal.
Hot Searches