- Product Details
- {{item.text}}
Quick Details
-
Warranty:
-
13month
-
Brand Name:
-
SUNCENTER
-
Model Number:
-
DGT
-
Place of Origin:
-
Guangdong, China
-
Horsepower:
-
10HP
-
Cable Length:
-
none
-
Outlet Size:
-
NONE
-
Power:
-
Pneumatic
-
motor:
-
none
-
Product name:
-
Oxygen booster pump for laser cutting
-
Model:
-
DGT SERIAL
-
Material:
-
Stainless Steel
-
Boost Medium:
-
Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/CNG or other gas
-
Air driven pressure:
-
3-8bar
-
Certificate:
-
ISO9001:2008/CE
-
Max pressure:
-
800 bar
-
inlet/ outlet connection:
-
NPT
-
Flow rate:
-
Max 230LPM
Quick Details
-
Application:
-
Metal and Equipment Manufacturers
-
Pressure:
-
High Pressure
-
Voltage:
-
High Pressure
-
Warranty:
-
13month
-
Brand Name:
-
SUNCENTER
-
Model Number:
-
DGT
-
Place of Origin:
-
Guangdong, China
-
Horsepower:
-
10HP
-
Cable Length:
-
none
-
Outlet Size:
-
NONE
-
Power:
-
Pneumatic
-
motor:
-
none
-
Product name:
-
Oxygen booster pump for laser cutting
-
Model:
-
DGT SERIAL
-
Material:
-
Stainless Steel
-
Boost Medium:
-
Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/CNG or other gas
-
Air driven pressure:
-
3-8bar
-
Certificate:
-
ISO9001:2008/CE
-
Max pressure:
-
800 bar
-
inlet/ outlet connection:
-
NPT
-
Flow rate:
-
Max 230LPM
Gas booster pump
Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series
Suncenter Air Driven Gas Boosters provide for pressures up to
80Mpa (11,600 psi)
. Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:
Compressed Air driven - no electricity required (connect to normal air compressor)
In order to extend the lifetime of the pump, the driving air pressure should
not be higher than
8 bar
No airline lubricator required
Hydrocarbon free - separation between air and gas sections
Pressures to 80Mpa (11,600 psi)
Wide range of models with different ratios
Built-in-cooling on most models
Easy to install, operate and maintain
Best price / performance ratio
No heat, flame or spark risk and explosion proof
Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter pump will automatically start, keep the loop pressure constant
Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen)
CO22/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc
Applications for Air Driven Gas Boosters
SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.
Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.
As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.
SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.
Applications
Pressure test with gas/air
Gas transfer and filling
(Air/Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO22/CH4/LNG/LPG/CNG/FM200 etc.)
Charging of gas cylinder and accumulator with nitrogen
Nitrogen gas spring charging
Supply for isolating gas systems
Gas assisted injection molding
Transfer of oxygen cylinders
Charging of breathing air bottles
Leak test
Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
Safety valve adjusting
DGA series gas booster pumps(Single acting, single air drive head):
DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.
Technical specification for DGA Series:
(Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure)
Model
|
Pressure boost ratio
|
Min. gas
Inlet pressure PA (bar) |
Max.gas
Inlet pressure PA (bar) |
Max. gas
outlet pressure PB (bar) |
Driven air pressure PL |
Formula to
calculate gas outlet pressure PB |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min)
|
DGA02
|
2:1
|
1.0
|
16
|
16
|
2bar-8 bar
|
2X PL
|
1/2 / 1/2
|
960 (at PA of 6 bar )
|
DGA05
|
5:1
|
0
|
40
|
40
|
2bar-8 bar
|
5XPL
|
1/2 / 1/2
|
680(at PA of 6 bar )
|
DGA06
|
6:1
|
2.0
|
48
|
48
|
2bar-8 bar
|
6XPL
|
1/2 / 1/2
|
360(at PA of 10 bar )
|
DGA10
|
10:1
|
3.5
|
80
|
80
|
2bar-8 bar
|
10XPL
|
3/8/ 3/8
|
210(at PA of 10 bar )
|
GA15
|
15:1
|
3.5
|
120
|
120
|
2bar-8 bar
|
15XPL
|
3/8/ 3/8
|
190(at PA of 10 bar )
|
DGA25
|
25:1
|
7.0
|
200
|
200
|
2bar-8 bar
|
25XPL
|
1/4/ 1/4
|
120(at PA of 20 bar )
|
DGA40
|
40:1
|
10
|
320
|
320
|
2bar-8 bar
|
40XPL
|
1/4/ 1/4
|
200(at PA of 40 bar )
|
DGA60
|
60:1
|
20
|
480
|
480
|
2bar-8 bar
|
60XPL
|
1/4/ 1/4
|
180(at PA of 40 bar )
|
DGA100
|
100:1
|
25
|
800
|
800
|
2bar-8 bar
|
100XPL
|
1/4/ M14X1.5
|
136(at PA of 40 bar )
|
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, with single air driven heads type.
DGD pumps are available with high quality seals, which provide significantly better service life
Double pump heads with exhaust cooling devices.
All components in contact with the gas are made of stainless steel.
Pipes mounting way are available as customized.
Technical specification for DGD Series:
(Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure)
Model
|
Pressure boost ratio
|
Min. gas
Inlet pressure PA (bar) |
Max.gas
Inlet pressure PA (bar) |
Max. gas
outlet pressure PB (bar) |
Driven air pressure PL |
Formula to
calculate gas outlet pressure PB |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min)
|
DGD10
|
10:1
|
3.5
|
80
|
80
|
2bar-8 bar
|
10XPL+ PA
|
3/8/3/8
|
410(at PA of 6 bar )
|
DGD15
|
15:1
|
5
|
120
|
120
|
2bar-8 bar
|
15XPL+ PA
|
3/8/3/8
|
350 (at PA of 6 bar )
|
DGD25
|
25:1
|
10
|
200
|
200
|
2bar-8 bar
|
25XPL+ PA
|
1/4/1/4
|
396(at PA of 20 bar )
|
DGD40
|
40:1
|
15
|
320
|
320
|
2bar-8 bar
|
40XPL+ PA
|
1/4/1/4
|
320(at PA of 40 bar )
|
DGD60
|
60:1
|
25
|
480
|
480
|
2bar-8 bar
|
60XPL+ PA
|
1/4/1/4
|
215(at PA of 40 bar )
|
DGD100
|
100:1
|
35
|
800
|
800
|
2bar-8 bar
|
100XPL+ PA
|
1/4/M14*1.5
|
300(at PA of 60 bar )
|
DGD130
|
130:1
|
50
|
1040
|
1040
|
2bar-8 bar
|
130XPL+ PA
|
1/4/M14*1.5
|
180(at PA of 60 bar )
|
2DGD series gas booster pumps(Double acting, double air driven heads ):
Technical specification for 2DGD Series:
(Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure)
Model
|
Pressure boost ratio
|
Min. gas
Inlet pressure PA (bar) |
Max.gas
Inlet pressure PA (bar) |
Max. gas
outlet pressure PB (bar) |
Driven air pressure PL
|
Formula to
calculate gas outlet pressure PB |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min)
|
2DGD10
|
10:1
|
3
|
80
|
80
|
2bar-8 bar
|
10XPL+ PA
|
1/2 / 1/2
|
980(at PA of 6 bar )
|
2DGD25
|
25:1
|
6
|
200
|
200
|
2bar-8 bar
|
25XPL+ PA
|
3/8 / 3/8
|
560(at PA of 10 bar )
|
2DGD40
|
40:1
|
25
|
320
|
320
|
2bar-8 bar
|
40XPL+ PA
|
3/8 / 3/8
|
480(at PA of 40 bar )
|
2DGD60
|
60:1
|
30
|
480
|
480
|
2bar-8 bar
|
60XPL+ PA
|
3/8 / 3/8
|
320(at PA of 40 bar )
|
DGT series gas booster pumps(Double acting, double stage, single air drive head ):
DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
DGT pumps are available with high quality seals, which provide significantly better service life
All parts in contact with the gas are made of stainless steel.
Technical specification for DGT Series:
(Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure)
Model
|
Pressure boost ratio
|
Min. gas
Inlet pressure PA (bar) |
Max.gas
Inlet pressure PA (bar) |
Max. gas
outlet pressure PB (bar) |
Driven air pressure PL |
Formula to
calculate gas outlet pressure PB |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min)
|
DGT15
|
15:1
|
0.1
|
56
|
120
|
2-8 bar
|
15XPL
|
3/8/ 1/4
|
230(at PA of 8 bar )
|
DGT25
|
25:1
|
0.1
|
10
|
200
|
2-8 bar
|
25XPL
|
3/8/ 1/4
|
156(at PA of 8 bar )
|
DGT7/25
|
25:1
|
5
|
56
|
200
|
2-8 bar
|
25XPL
|
3/8/ 1/4
|
156(at PA of 8 bar )
|
DGT40
|
40:1
|
0.1
|
10
|
320
|
2-8 bar
|
40XPL
|
3/8/ 1/4
|
124(at PA of 8 bar )
|
DGT15/40
|
40:1
|
5
|
120
|
320
|
2-8 bar
|
40XPL
|
3/8/ 1/4
|
124(at PA of 8 bar )
|
DGT60
|
60:1
|
0.1
|
10
|
480
|
2-8 bar
|
60XPL
|
3/8/ 1/4
|
80(at PA of 15 bar )
|
DGT15/60
|
60:1
|
6
|
120
|
480
|
2-8 bar
|
60XPL
|
3/8/ 1/4
|
80(at PA of 15 bar )
|
DGT100
|
100:1
|
0.1
|
10
|
800
|
2-8 bar
|
100XPL
|
3/8/ 1/4
|
63(at PA of 8 bar )
|
2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):
Technical specification for DGS-2DGT series:
Model
|
Pressure boost ratio
|
Min. gas
Inlet pressure PA (bar) |
Max.gas
Inlet pressure PA (bar) |
Max. gas
outlet pressure PB (bar) |
Driven air pressure PL |
Formula to
calculate gas outlet pressure PB |
Connection:
Gas Inlet / Gas outlet (NPT thread) |
Max. flow at driven air pressure of 6bar (L/min)
|
2DGT7/15
|
15:1
|
4
|
56
|
120
|
2bar-8 bar
|
15XPL
|
3/8 / 3/8
|
430(at PA of 10 bar )
|
2DGT7/25
|
25:1
|
5
|
56
|
200
|
2bar-8 bar
|
25XPL
|
3/8 / 3/8
|
300(at PA of 10 bar )
|
2DGT15/40
|
40:1
|
7
|
120
|
320
|
2bar-8 bar
|
40XPL
|
3/8 / 3/8
|
180(at PA of 10 bar )
|
2DGT15/60
|
60:1
|
7
|
120
|
480
|
2bar-8 bar
|
60XPL
|
3/8 / 3/8
|
120(at PA of 10 bar )
|
Note: PL: driven air pressure PA: gas inlet pressure PB: gas outlet pressure
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
How to Select Suncenter Air Driven Gas Boosters/Systems?
In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?( )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?( )bar
4.What driven air pressure (of your air compressor) can you offer?( )bar,
because our booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?( )L/min
DGT series gas booster working picture
Gas pressure booster for cylinder transfer and filling
Company Introduction
Dongguan Suncenter Fluid Control Equipment Co., Ltd
is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.
Our main products including:
1. High Pressure Booster Pumps ( Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
2. High Pressure Systems (Gas/Liquid Booster System,Hydro test bench,Chemical injection system,CO2/FM200 filling machine, Tube Expanding Machine)
3. High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine, Valve test bench,Impulse Testing Machine, etc.)
4. Hydro-pneumatic cylinders and machines(pneumatic hydraulic cylinders,pneumatic riveting machines,pneumatic press machines etc.)
Customer review