Products
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling
Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling

Suncenter factory price double acting CO2 N2 O2 gas booster pump for cylinder filling

FOB Reference Price: Get Latest Price
≥1 Sets
US $1500
≥5 Sets
US $1400
≥10 Sets
US $1300
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Warranty:
13month
Brand Name:
SUNCENTER
Model Number:
DGT
Place of Origin:
Guangdong, China
Horsepower:
10HP
Cable Length:
none
Outlet Size:
NONE
Power:
Pneumatic
motor:
none
Product name:
Oxygen booster pump for laser cutting
Model:
DGT SERIAL
Material:
Stainless Steel
Boost Medium:
Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/CNG or other gas
Air driven pressure:
3-8bar
Certificate:
ISO9001:2008/CE
Max pressure:
800 bar
inlet/ outlet connection:
NPT
Flow rate:
Max 230LPM

Quick Details

Application:
Metal and Equipment Manufacturers
Pressure:
High Pressure
Voltage:
High Pressure
Warranty:
13month
Brand Name:
SUNCENTER
Model Number:
DGT
Place of Origin:
Guangdong, China
Horsepower:
10HP
Cable Length:
none
Outlet Size:
NONE
Power:
Pneumatic
motor:
none
Product name:
Oxygen booster pump for laser cutting
Model:
DGT SERIAL
Material:
Stainless Steel
Boost Medium:
Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/CNG or other gas
Air driven pressure:
3-8bar
Certificate:
ISO9001:2008/CE
Max pressure:
800 bar
inlet/ outlet connection:
NPT
Flow rate:
Max 230LPM
Gas booster pump



Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series

Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi) . Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include:
Compressed Air driven - no electricity required (connect to normal air compressor) In order to extend the lifetime of the pump, the driving air pressure should not be higher than 8 bar No airline lubricator required Hydrocarbon free - separation between air and gas sections Pressures to 80Mpa (11,600 psi)   Wide range of models with different ratios Built-in-cooling on most models Easy to install, operate and maintain Best price / performance ratio No heat, flame or spark risk and explosion proof Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant Applicable gas:Air/Ar(Argon)/He(Helium)/H2(Hydrogen)/O2(Oxygen)N2(Nitrogen) CO22/CH4/C2H2/LNG/LPG/CNG/FM200/SF6/H2S etc


Applications for Air Driven Gas Boosters

SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.

Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.

As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities.

SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances.



Applications

Pressure test with gas/air Gas transfer and filling (Air/Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO22/CH4/LNG/LPG/CNG/FM200 etc.) Charging of gas cylinder and accumulator with nitrogen Nitrogen gas spring charging Supply for isolating gas systems Gas assisted injection molding Transfer of oxygen cylinders Charging of breathing air bottles Leak test Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components Safety valve adjusting



DGA series gas booster pumps(Single acting, single air drive head):

DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.



Technical specification for DGA Series:

(Note: PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure)
Model
Pressure boost ratio
Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
DGA02
2:1
1.0
16
16
2bar-8 bar
2X PL
1/2 / 1/2
960 (at PA of 6 bar )
DGA05
5:1
0
40
40
2bar-8 bar
5XPL
1/2 / 1/2
680(at PA of 6 bar )
DGA06
6:1
2.0
48
48
2bar-8 bar
6XPL
1/2 / 1/2
360(at PA of 10 bar )
DGA10
10:1
3.5
80
80
2bar-8 bar
10XPL
3/8/ 3/8
210(at PA of 10 bar )
GA15
15:1
3.5
120
120
2bar-8 bar
15XPL
3/8/ 3/8
190(at PA of 10 bar )
DGA25
25:1
7.0
200
200
2bar-8 bar
25XPL
1/4/ 1/4
120(at PA of 20 bar )
DGA40
40:1
10
320
320
2bar-8 bar
40XPL
1/4/ 1/4
200(at PA of 40 bar )
DGA60
60:1
20
480
480
2bar-8 bar
60XPL
1/4/ 1/4
180(at PA of 40 bar )
DGA100
100:1
25
800
800
2bar-8 bar
100XPL
1/4/ M14X1.5
136(at PA of 40 bar )




DGD series gas booster pumps(Double acting ):

DGD series pumps are double acting, with single air driven heads type. DGD pumps are available with high quality seals, which provide significantly better service life Double pump heads with exhaust cooling devices. All components in contact with the gas are made of stainless steel. Pipes mounting way are available as customized.


Technical specification for DGD Series:

(Note: PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure)
Model
Pressure boost ratio
Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
DGD10
10:1
3.5
80
80
2bar-8 bar
10XPL+ PA
3/8/3/8
410(at PA of 6 bar )
DGD15
15:1
5
120
120
2bar-8 bar
15XPL+ PA
3/8/3/8
350 (at PA of 6 bar )
DGD25
25:1
10
200
200
2bar-8 bar
25XPL+ PA
1/4/1/4
396(at PA of 20 bar )
DGD40
40:1
15
320
320
2bar-8 bar
40XPL+ PA
1/4/1/4
320(at PA of 40 bar )
DGD60
60:1
25
480
480
2bar-8 bar
60XPL+ PA
1/4/1/4
215(at PA of 40 bar )
DGD100
100:1
35
800
800
2bar-8 bar
100XPL+ PA
1/4/M14*1.5
300(at PA of 60 bar )
DGD130
130:1
50
1040
1040
2bar-8 bar
130XPL+ PA
1/4/M14*1.5
180(at PA of 60 bar )




2DGD series gas booster pumps(Double acting, double air driven heads ):


Technical specification for 2DGD Series:

(Note: PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure)
Model
Pressure boost ratio
Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)
Driven air pressure PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
2DGD10
10:1
3
80
80
2bar-8 bar
10XPL+ PA
1/2 / 1/2
980(at PA of 6 bar )
2DGD25
25:1
6
200
200
2bar-8 bar
25XPL+ PA
3/8 / 3/8
560(at PA of 10 bar )
2DGD40
40:1
25
320
320
2bar-8 bar
40XPL+ PA
3/8 / 3/8
480(at PA of 40 bar )
2DGD60
60:1
30
480
480
2bar-8 bar
60XPL+ PA
3/8 / 3/8
320(at PA of 40 bar )





DGT series gas booster pumps(Double acting, double stage, single air drive head ):

DGT pumps are double acting, double stage with single air drive head pumps. They can provide for super high pressure with very low inlet pressure.
DGT pumps are available with high quality seals, which provide significantly better service life  All parts in contact with the gas are made of stainless steel.



Technical specification for DGT Series:

(Note: PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure)
Model
Pressure boost ratio
Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
DGT15
15:1
0.1
56
120
2-8 bar
15XPL
3/8/ 1/4
230(at PA of 8 bar )
DGT25
25:1
0.1
10
200
2-8 bar
25XPL
3/8/ 1/4
156(at PA of 8 bar )
DGT7/25
25:1
5
56
200
2-8 bar
25XPL
3/8/ 1/4
156(at PA of 8 bar )
DGT40
40:1
0.1
10
320
2-8 bar
40XPL
3/8/ 1/4
124(at PA of 8 bar )
DGT15/40
40:1
5
120
320
2-8 bar
40XPL
3/8/ 1/4
124(at PA of 8 bar )
DGT60
60:1
0.1
10
480
2-8 bar
60XPL
3/8/ 1/4
80(at PA of 15 bar )
DGT15/60
60:1
6
120
480
2-8 bar
60XPL
3/8/ 1/4
80(at PA of 15 bar )
DGT100
100:1
0.1
10
800
2-8 bar
100XPL
3/8/ 1/4
63(at PA of 8 bar )




2DGT series gas booster pumps(Double acting, double stage,double air driven heads ):



Technical specification for DGS-2DGT series:

Model
Pressure boost ratio
Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
2DGT7/15
15:1
4
56
120
2bar-8 bar
15XPL
3/8 / 3/8
430(at PA of 10 bar )
2DGT7/25
25:1
5
56
200
2bar-8 bar
25XPL
3/8 / 3/8
300(at PA of 10 bar )
2DGT15/40
40:1
7
120
320
2bar-8 bar
40XPL
3/8 / 3/8
180(at PA of 10 bar )
2DGT15/60
60:1
7
120
480
2bar-8 bar
60XPL
3/8 / 3/8
120(at PA of 10 bar )
Note: PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar

How to Select Suncenter Air Driven Gas Boosters/Systems?

In order to choose suitable booster pump or systems for you,
please kindly reply us the following questions:
1.What is your present gas pressure?(    )bar
2.What is your gas?oxygen gas,nitrogen gas or other gases?
3.What outlet gas pressure do you want?(    )bar
4.What driven air pressure (of your air compressor) can you offer?(    )bar,
because our booster is completely air operated and no need any electricity
5.What outlet gas flow rate do you need?(    )L/min


DGT series gas booster working picture

Gas pressure booster for cylinder transfer and filling

DGD series oxygen gas booster working picture
Company Introduction
Dongguan Suncenter Fluid Control Equipment Co., Ltd is the member company of Suncenter Group, which is located in Dongguan city of Guangdong province in China. With more than 15 years experiences in fluid pressure exchange and controlling field, we provide various kinds of pneumatic and hydraulic booster pumps, systems and solutions to the customers all over the world. Due to our best product quality, competitive price as well as excellent after-sales service, we have win a great reputation in the field.

Our main products including:
1. High Pressure Booster Pumps ( Gas Booster Pump, Air Driven Liquid Pump, Air Amplifiers)
2. High Pressure Systems (Gas/Liquid Booster System,Hydro test bench,Chemical injection system,CO2/FM200 filling machine, Tube Expanding Machine)  3. High Pressure Test Equipment(Hydraulic/Burst/Hydrostatic test machine,Cylinder test machine, Valve test bench,Impulse Testing Machine, etc.)  4. Hydro-pneumatic cylinders and machines(pneumatic hydraulic cylinders,pneumatic riveting machines,pneumatic press machines etc.)

Customer review
APP
Post My RFQ
WhatsApp
+86-17326049340