- Product Details
- {{item.text}}
Quick Details
-
EINECS No.:
-
NA
-
Place of Origin:
-
Izmir, Turkey
-
Brand Name:
-
ISONEM
-
Model Number:
-
ANTIFIRE PAINT PLUS
-
Application:
-
Metal, Concrete, Wood
Quick Details
-
CAS No.:
-
NA
-
Other Names:
-
Intumescent Paint
-
MF:
-
NA
-
EINECS No.:
-
NA
-
Place of Origin:
-
Izmir, Turkey
-
Brand Name:
-
ISONEM
-
Model Number:
-
ANTIFIRE PAINT PLUS
-
Application:
-
Metal, Concrete, Wood
ISONEM ANTIFIRE PAINT PLUS
FIRE RETARDANT INTUMESCENT PAINT FOR STEEL, CONCRETE AND WOODEN STRUCTURES!!
120 MINUTES FIRE PROTECTION
Fire resistant paint for steel, reinforced concrete and wooden buildings
It is developed for protecting buildings against fire. It is a fire retardant, water based paint, with intumescence structure, providing fire insulation by expansion. It dries and creates a seamless layer on the surface to which it is applied. It has an excellent flame retardant feature. It reacts chemically
during fire, swells and prevents the temperature at the surface from reaching critical levels. It is permeable to steam. Thanks to this feature, it doesn’t prevent the surface to which it is applied from breathing. It is very suitable for using in wooden, reinforced concrete, prefabricated, and steel structures.
TECHNICAL PROPERTIES: •Color: white or the requested colors •Density: 1,15±0,05 kg/l •Solid (by weight): 60% ± 2%. •pH: 7-9 •Drying time: 6 hours •Application temperature: over +5 °C •Tensile strength: 2 N/mm at +23 °C •Fire resistance classification: the fire resistance classification was obtained as R15 – R20 – R30 – R45 – R60 and R90 in the tests performed according to the TS EN 13381-82013 Test method for determining the contribution of the building element to the fire resistance – Part 8: test method for reactive protection applied to the steel elements according to the result of the inspection and test report, dated: 20.04.2017 no: 339190/04-17 in the inspections and tests made according to the TS
EN 13501-2:2016 Building finished products and building elements – Fire classification – Part 2: classification by using the date obtained from fire resistance tests (excluding ventilation installments).
According to the results of the inspection test of TSE Building Materials Fire and Acoustic Laboratory Department:
Main paint layer (intumescent paint): ISONEM ANTIFIRE PAINT PLUS.
Finishing layer paint (top coat): ISONEM ANTIFIRE PAINT.
Steel class: S275JR
Nominal protection thickness: 1.5 mm,
Protection way: all periphery
Permitted cross section factor interval 71: m-1 ≤ Am ≤ 453 m-1
Steel classes: it is valid for the classes stated in EN 10025-1 (excluding S185). It may not be used for class E steels. The results are also valid for the
artificial cuts.
Maximum beam depth : 600 mm
The sides which are subjected to: being subjected to from the sides 3 and 4.
Design steel temperatures: 350°C ≤ Qa ≤ 750°C
Fire resistance classes: R15 – R20 – R30 – R45 – R60 and R90, R-120, R-180
Surface Preparation: Before application, all surfaces must be clean and dry, cleansed of oil, dirt, mud and other similar substances. Before use, open the packaging and stir to ensure homogeneity.
+90 (533) 581 05 54 (Mobile/WhatsApp/Viber)
WeChat: behiyebaser
TECHNICAL FEATURES: •Color: White or any color of preference •Application temperature: Over + 5°C •Water absorption feature: 12% •Steam permeability: 2 o 20 g/m2 •Tensile strength: 2 N/mm at + 23°C •Breaking elongation: 50% at + 23°C •Fire retardant feature: It CONFORMS to TS 13501-1/JANUARY 2010 Schedule 1 B S1 d0 requirements in accordance with the examination and experiments performed based on TS EN 13823:March 2010 standard, examination and experiment report results referenced TS ISO 11925-2, dated 02.2012 / No. 139921. ACCORDING TO THE RESULT OF EX LAB EXAMINATION EXPERIMENT BY DIRECTORATE OF TSE EXPERIMENT and CALIBRATION CENTER; Reaction of the experiment sample to fire in EN 13501-1 B (in accordance with the European classification) test method: PASSED Test of experiment samples pursuant to TS EN ISO 11925-2 test method; •Inflammation of samples: DID NOT OCCUR Flames DID NOT REACH 150 mm testing line during the experiment period •Dripping of samples: DID NOT OCCUR •Filter paper: DID NOT BURN •Experiment sample just: MELTED •Lateral fire spread on the longitude: DID NOT OCCUR •Fire particles or drops f<10s and f>10s: DID NOT OCCUR •Smoke spread from the sample into the room: DID NOT OCCUR •Early termination of the experiment: DID NOT OCCUR •Sample deterioration or denture: DID NOT OCCUR SUMMARY OF THE TSE TEST RESULT: •Average FIGRA value (W/s): 17,24 •Average THR600s (MJ): 0,93 •Average SMORA value (m2/s2): 10,58 •Average TSP600s (m2): 51,86 •Up to LFS line (mm): DID NOT OCCUR •Burning drops/particles <_10s: DID NOT OCCUR •Burning drops/particles >10s:
DID NOT OCCUR RESULT: During the examinations and tests performed on ISONEM ANTI FIRE PAINT PLUS ‘’inflammable paint’’ sample pursuant to TS EN 13823:MARCH 2010 standard, result of the examination and experiment reference TS EN ISO 11925-2, dated 02.2012/No. 139921 CONFORMS to TS EN 13501-1/ JANUARY 2010 Schedule 1 B S1 d0 classification criteria.