Quick Details
-
Model Number:
-
PMD75
-
Accuracy:
-
Standard: 0.05% Platinum: up to 0.035%
-
Max. measurement error:
-
0,075% "PLATINUM" 0,05%
-
Process temperature:
-
-40 °C...85 °C
-
Pressure measuring range:
-
10 mbar...250 bar
-
Process pressure absolute:
-
420BAR
-
Material process membrane:
-
316L, AlloyC,
-
Measuring cell:
-
10 mbar...250 bar
-
Measuring principle:
-
Differential pressure
-
Outputs:
-
4...20mA HART
-
colour:
-
blue
Quick Details
-
Warranty:
-
1 year
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
endress&hauser
-
Model Number:
-
PMD75
-
Accuracy:
-
Standard: 0.05% Platinum: up to 0.035%
-
Max. measurement error:
-
0,075% "PLATINUM" 0,05%
-
Process temperature:
-
-40 °C...85 °C
-
Pressure measuring range:
-
10 mbar...250 bar
-
Process pressure absolute:
-
420BAR
-
Material process membrane:
-
316L, AlloyC,
-
Measuring cell:
-
10 mbar...250 bar
-
Measuring principle:
-
Differential pressure
-
Outputs:
-
4...20mA HART
-
colour:
-
blue
Product Description
The Deltabar PMD75 differential pressure transmitter with piezoresistive sensor and welded metallic membrane is used in all industries for continuous measurement in liquids, vapors and gases. The 3-key operation enables simple and reliable commissioning and operation. The integrated HistoROM data module allows easy management of process and device parameters. Designed according to IEC 61508 for use in SIL2/3 safety applications.
Benefits
* Best accuracy, reproducibility and long-term stability
* Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Cost savings with modular concept for easy replacement of sensor, display or electronics
* Overload-resistant up to 420bar / 42MPa / 6300psi, function-monitored
* Seamless and independent system integration (HART/PA/FF)
* Highest safety due to gas tight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
* Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Cost savings with modular concept for easy replacement of sensor, display or electronics
* Overload-resistant up to 420bar / 42MPa / 6300psi, function-monitored
* Seamless and independent system integration (HART/PA/FF)
Specification
item
|
value
|
Warranty
|
1 year
|
Place of Origin
|
China
|
|
Jiangsu
|
Brand Name
|
endress&hauser
|
Model Number
|
PMD75
|
Accuracy
|
0,1% "PLATINUM" 0,075%
|
Max. measurement error
|
0,1% "PLATINUM" 0,075%
|
Process temperature
|
-40 °C...85 °C (-40 °F...185 °F)
|
Medium temperature range
|
Temperature gradient from pressure piping
|
Pressure measuring range
|
10mbar...40bar (0.15...580psi)
|
Main wetted parts
|
316L
|
Material process membrane
|
316L, AlloyC,
|
Measuring cell
|
10 mbar...250 bar
|
Measuring principle
|
Differential pressure
|
Outputs
|
4...20mA HART
|