- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Guangdong, China
-
Water input pressure:
-
0.1Mpa-0.6Mpa, 15P.S.I-60P.S.I
-
Water input temperature:
-
5℃-30℃
-
Working environment temperature:
-
10℃-30℃ at relative humidity <=70%
-
Flow range:
-
0ml/h~4000ml/h
-
Resolution ratio:
-
1ml
-
Blood pump flow range:
-
10ml/min-600ml/min (diameter: 8mm or 6mm)
-
Substitution pump flow range:
-
10ml/min-300ml/min (diameter 8mm or 6mm)
-
Venous pressure:
-
-180mmHg +600mmHg, ±10mmHg
-
Arterial pressure:
-
-380mmHg +400mmHg, ±10mmHg
-
Dialysate temperature:
-
preset range 34.0℃-39.0℃
Quick Details
-
Warranty:
-
3 years
-
After-sale Service:
-
Onsite Training
-
Brand Name:
-
NA
-
Place of Origin:
-
Guangdong, China
-
Water input pressure:
-
0.1Mpa-0.6Mpa, 15P.S.I-60P.S.I
-
Water input temperature:
-
5℃-30℃
-
Working environment temperature:
-
10℃-30℃ at relative humidity <=70%
-
Flow range:
-
0ml/h~4000ml/h
-
Resolution ratio:
-
1ml
-
Blood pump flow range:
-
10ml/min-600ml/min (diameter: 8mm or 6mm)
-
Substitution pump flow range:
-
10ml/min-300ml/min (diameter 8mm or 6mm)
-
Venous pressure:
-
-180mmHg +600mmHg, ±10mmHg
-
Arterial pressure:
-
-380mmHg +400mmHg, ±10mmHg
-
Dialysate temperature:
-
preset range 34.0℃-39.0℃
Medical Blood Double Pump Kidney Dialysis Machine
LOGO printing, customization is supported
Product Description


Intelligent Operation
1. 12.1 inch LCD+touch screen, muti-language operation interface.
2. Adjust the level o f venous bubble catcher automatically to prevent blood pollution and reduce dialysis risk.
3. Convenient process for sequential dialysis(Dialysis ←→ IUF ) and high-low sodium sequential
dialysis.
Safe & Effective Treatment
1. The hydraulic,blood circuit and monitor system can be mandatory self-test, so that ensure the safety treatment.
2. Ultrasonic and optical detector on venous ensures the safety of blood return.
3. Dialysate configuration feedback control system to ensure accurate dialysate concentration.
4. Advanced capacity balance feedback control system, ensures UF precision.
Visual Intelligent System
1. Preset automatic switch time and disinfection mode, and record all disinfection.
2. Dynamic tracking and monitoring functions such as arterial pressure, venous pressure and transmembrane pressure can respond to
abnormal situations on time and alarm.
Powerful Compatibility
1. Can be operated with Various brands of filters.
2. Compatible with various brands of dialysis powder, bloodline and other hemodialysis consumables.
1. 12.1 inch LCD+touch screen, muti-language operation interface.
2. Adjust the level o f venous bubble catcher automatically to prevent blood pollution and reduce dialysis risk.
3. Convenient process for sequential dialysis(Dialysis ←→ IUF ) and high-low sodium sequential
dialysis.
Safe & Effective Treatment
1. The hydraulic,blood circuit and monitor system can be mandatory self-test, so that ensure the safety treatment.
2. Ultrasonic and optical detector on venous ensures the safety of blood return.
3. Dialysate configuration feedback control system to ensure accurate dialysate concentration.
4. Advanced capacity balance feedback control system, ensures UF precision.
Visual Intelligent System
1. Preset automatic switch time and disinfection mode, and record all disinfection.
2. Dynamic tracking and monitoring functions such as arterial pressure, venous pressure and transmembrane pressure can respond to
abnormal situations on time and alarm.
Powerful Compatibility
1. Can be operated with Various brands of filters.
2. Compatible with various brands of dialysis powder, bloodline and other hemodialysis consumables.
Specification
Hot disinfection
|
Time: 30 minutes; Temperature: about 80℃, at flow rate 500ml/min;
|
|
|
|
|||
Chemical disinfection
|
Time: 30minutes, Temperature: about 36℃~50℃, at flow rate 500ml/min;
|
|
|
|
|||
Chemical disinfection with heat
|
Time: 45minutes, Temperature: about 36℃~80℃, at flow rate 50ml/min;
|
|
|
|
|||
Rinse
|
Time: 10minutes, Temperature: about 37℃, at flow rate 800ml/min;
|
|
|
|
|||
Storage Environment
|
Storage temperature should be between 5℃~40℃, at relative humidity ≦80%
|
|
|
|
|||
Function
|
HDF, on-line BPM, Bi-cart and 2 pcs endotoxin filters
|
|
|
|
|||
More information
|