- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Shandong, China
-
Brand Name:
-
WFP
-
Model Number:
-
WFP
-
Speed:
-
1500/1800rpm
-
Product Name:
-
gas generator
-
Type:
-
Silent(super Silent)or Open
-
Color:
-
Customers' Request
-
Fuel Tank:
-
10 Hours Working Time
-
Package:
-
Plastic Film Packing
-
MOQ:
-
1
-
Certification:
-
CE
Quick Details
-
Rated Voltage:
-
380/220V, 400/230V,415/240V, 440/254V, 220/110V
-
Rated Current:
-
18A-545A
-
Frequency:
-
50HZ/60HZ
-
Place of Origin:
-
Shandong, China
-
Brand Name:
-
WFP
-
Model Number:
-
WFP
-
Speed:
-
1500/1800rpm
-
Product Name:
-
gas generator
-
Type:
-
Silent(super Silent)or Open
-
Color:
-
Customers' Request
-
Fuel Tank:
-
10 Hours Working Time
-
Package:
-
Plastic Film Packing
-
MOQ:
-
1
-
Certification:
-
CE
Product Description
10-500kw gas generator price
10-500kw natural gas generator price meeting the requirements of environmental protection and new market environment. The fuel can be natural gas, biogas or LPG. They are widely used in areas of oil fields and regions abundant in natural gas or biogas. The genset is quick to start and easy to operate with complete protection system. Most of its economic parameters are capable of leading this industry. The gensets can be used as power stations for oil fileds and local enterprises.
* Technical Advantages:
1. Adopting advanced Hall ignition sensor and Highly capable ignition system, the engine ignition will be more reliable, and
easier to start.
2. Main control parts are imported from USA and Italy, to make more stable and reliable running.
3. Several gensets can be parallel connection , which can increase the total power range. In addition,the gensets can take
maintenance in different times,which will make little influence to the normal performance of gensets.
4. Low gas pressure is acceptable, no need to set up specified gas storage tank , which will save the investment and enhance the
efficient output power .
5. Self-contained parts of gensets needs few accessories
6. Economical and low-cost running.
7.The fuel of gas reduces the accumulated carbon, which lessen the damage to between cylinder and valve, therefore, it will largely prolong lifetime.
8. The installation of high-quality control cabinet set enable multiple protection, which enhance the safety for the running of gensets.
easier to start.
2. Main control parts are imported from USA and Italy, to make more stable and reliable running.
3. Several gensets can be parallel connection , which can increase the total power range. In addition,the gensets can take
maintenance in different times,which will make little influence to the normal performance of gensets.
4. Low gas pressure is acceptable, no need to set up specified gas storage tank , which will save the investment and enhance the
efficient output power .
5. Self-contained parts of gensets needs few accessories
6. Economical and low-cost running.
7.The fuel of gas reduces the accumulated carbon, which lessen the damage to between cylinder and valve, therefore, it will largely prolong lifetime.
8. The installation of high-quality control cabinet set enable multiple protection, which enhance the safety for the running of gensets.
* Gas Generator Set working condition:
Normal working conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 25°C, Relative Humidity: 30%, Altitude: ≤1000m
Gas requirement:
Applied gas type :
Nature Gas, Biogas, LPG, CNG, LNG, oil field gas, Syngas, Coal bed methane, straw gas,wood gas etc.
Gas inlet pressure: 0.8-2.0kPa, higher water pressure must use additional decompression machine.
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ).
Nature Gas, Biogas, LPG, CNG, LNG, oil field gas, Syngas, Coal bed methane, straw gas,wood gas etc.
Gas inlet pressure: 0.8-2.0kPa, higher water pressure must use additional decompression machine.
Gas heat value≥5500kcal/Nm3 (23MJ/Nm3 ).
Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it
will lower the power efficiency.)
The gas must be to desulfurize and dehydrate and dust removal.
H2S ≤ 200mg/Nm3
NH3 content≤20mg/Nm3
Impurity granularity ≤ 5 μm
Impurity content ≤ 30 mg/Nm3
No liquid ingredients (not including free water, light hydrocarbon)
CH4 content ≥ 55%
NH3 content≤20mg/Nm3
Impurity granularity ≤ 5 μm
Impurity content ≤ 30 mg/Nm3
No liquid ingredients (not including free water, light hydrocarbon)
CH4 content ≥ 55%
![](https://cdn.bestsuppliers.com/seo_products_img/weifangpower/0349c2f2198532b8883035c8842a943a.jpg!/rotate/180)
![](https://cdn.bestsuppliers.com/seo_products_img/weifangpower/89609228f7b03e71afca0431ac82e501.jpg!/rotate/180)
![](https://cdn.bestsuppliers.com/seo_products_img/weifangpower/de57e8446d9c39f2a6fc84e54dd26809.png!/rotate/180)
![](https://cdn.bestsuppliers.com/seo_products_img/weifangpower/44ff76a50bbe3cd18ec7beef5fbe8eff.jpg!/rotate/180)
* Our Main Products
* Optional Automatic Control Digital System
1) Brand: Deepsea, Harsen, Smartgen, etc.
2) Adopt Genset controller with LCD display, taking microprocessor as the core.
3) The monitor and display on the voltage, current, frequency, active power, apparent power, power factor of the generated
electricity /grid electricity.
4) The monitor and display on the genset’s water temperature, oil pressure, rotational speed, battery voltage, running hours,
accumulative total power and number of starts.
5) Protection alarm and fault automatic storage on high water temperature, low oil pressure, double speeding, over current, over
voltage, over frequency and phase failure etc.
2) Adopt Genset controller with LCD display, taking microprocessor as the core.
3) The monitor and display on the voltage, current, frequency, active power, apparent power, power factor of the generated
electricity /grid electricity.
4) The monitor and display on the genset’s water temperature, oil pressure, rotational speed, battery voltage, running hours,
accumulative total power and number of starts.
5) Protection alarm and fault automatic storage on high water temperature, low oil pressure, double speeding, over current, over
voltage, over frequency and phase failure etc.
Specification
Generator
|
Frequency(HZ)
|
50hz/60hz
|
|
Rated. AC voltage(v)
|
120, 220, 230, 240, 380, 400
|
Generator
|
Phase
|
Single phase or Three phase
|
|
Starting system
|
Electric
|
|
Radiator
|
40℃ for open type, 50℃ for silent type
|
|
Tool Kits & Manuals
|
Standard tool kits and complete operation/maintenance/manuals for Generator/Engine/Alternator/control panel, etc.
|
Optional Features
|
DC circuit breaker
|
Optional
|
|
Calculagraph
|
|
|
Big Wheel
|
|
|
Three phase voltage
|
|
|
Current meter
|
|
|
ATS
|
|
|
Remote control
|
|
|
Welding
|
|