5. CAN interface
6. Auto paralleling Bus connectors for connecting Master Unit-to-Slave and Slave Unit-to-Slave unit
7 .Remote voltage compensation terminal
8.DC output (
positive &
negative)
9.Shell ground pillar
10. AC input terminal(N+L+G)
11. Analog signal monitoring and control interface
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
Jingri
-
Model Number:
-
DP1000-3.4-BS
-
Output Frequency:
-
N/A
-
Output Current:
-
3.4A
-
Color:
-
Grey
-
Voltage Adj. Range:
-
0-1050V
-
Current Adj. Range:
-
0-3.6A
-
Rated Power:
-
3400W( (OPP=110% of rated value)
-
Warranty:
-
2 Years
-
Size:
-
W: 420mm, H: 43.5mm, D: 443mm (Without busbars and busbars cover)
-
Weight:
-
6.5kg
-
Display Type:
-
3.12 inch OLED
-
Interface:
-
LAN, USB, RS-232/RS-485,CAN,I/O
-
MOQ:
-
1 set
Quick Details
-
Input Voltage:
-
Single phase 170~265Vac
-
Output Voltage:
-
1000V
-
Place of Origin:
-
Zhejiang, China
-
Brand Name:
-
Jingri
-
Model Number:
-
DP1000-3.4-BS
-
Output Frequency:
-
N/A
-
Output Current:
-
3.4A
-
Color:
-
Grey
-
Voltage Adj. Range:
-
0-1050V
-
Current Adj. Range:
-
0-3.6A
-
Rated Power:
-
3400W( (OPP=110% of rated value)
-
Warranty:
-
2 Years
-
Size:
-
W: 420mm, H: 43.5mm, D: 443mm (Without busbars and busbars cover)
-
Weight:
-
6.5kg
-
Display Type:
-
3.12 inch OLED
-
Interface:
-
LAN, USB, RS-232/RS-485,CAN,I/O
-
MOQ:
-
1 set
Products Description
Product introduction
DP series high-precision programmable DC power supply is a cost-effective product with high-quality, high-power-density, multi-function, launched by our company to meet the needs of our customers. The maximum power of 1U model can reach 5KW, and the weight is only 7.5Kg. The specification voltage of this series of products can reach up to 3050V, and the maximum current can reach 525A. It built-in PFC power factor correction circuit, and the input voltage can meet the wide range of applications in the global power grid.
This series of power supply has constant voltage (CV) and constant current (CC) operating modes, and automatically switches between operating modes. It also has built-in user-settable constant power (CP) limit mode, built-in analog program control (5V/10V/5K/10K) signal, USB, LAN, CAN, RS-232/485 communication interface, and supports Modbus-RTU and SCPI industry standard communication protocol. Users can enter the menu to select their own protocol and communication mode as required.
Product features
19" rack mount capability for ATE and OEM application. (1U maximum power up to 5KW).
Active PFC
Built-in LAN, USB, RS-232/RS-485,CAN Interface
OLED display with 5 digits. Support Chinese and English dual language menu switching display.
Finally set the memory function and timer function.
Automatic start/safe start: user selectable
High Resolution: 16-bit ADC and DAC.
LIST programming dynamic output
CV, CC and CP operation modes
Voltage and current slope control
Local and remote sensing - software control.
Built in remote isolation simulation program control and monitoring interface
Fan controlled by load current
Support Modbus-RTU & SCPI industry communication protocols
Product selection function and optional model description
Details Images
Rear panel diagram
1.RS-232/485 DB9 interface
2.RS-232/RS-485 IN/OUT Remote Digital Interface (RJ-45 type) for Multi-Drop connection
3.USB interface (for internal calibration)
4.LAN interface
Product Paramenters
OUTPUT RATING
|
|
DP1000-3.4-BS
|
|
|
||||
Voltage adjustable range(*1)
|
|
1000V (0~1050V adjustable)
|
|
|
||||
Current adjustable range(*2)
|
|
3.4A( 0~3.6A adjustable)
|
|
|
||||
Rated power
|
|
3400W (OPP=110% of rated value)
|
|
|
||||
INPUT CHARACTERISTICS
|
|
|
|
|
||||
Input voltage
|
|
Single phase 170~265Vac
|
|
|
||||
Frequency
|
|
47~63Hz
|
|
|
||||
Power Factor (Typ)
|
|
0.99@200Vac,rated output power.
|
|
|
||||
Efficiency at 200Vac, rated output
|
|
90%
|
|
|
||||
CONSTANT VOLTAGE MODE
|
|
|
|
|
||||
Max. Line regulation(*3)
|
|
0.01% of rated output voltage
|
|
|
||||
Max. Load regulation(*4)
|
|
0.01% of rated output voltage+5mV
|
|
|
||||
Ripple and noise (p-p, 20MHz)
|
|
600mV
|
|
|
||||
Ripple r.m.s. 5Hz~1MHz
|
|
150mV
|
|
|
||||
Temperature coefficient
|
|
50PPM/°C from rated output voltage, following 30 minutes warm-up.
|
|
|
||||
Temperature stability
|
|
0.01% of rated Vout over 8hrs interval following 30 minutes warm-up. Constant line, load & temp.
|
|
|
||||
Warm-up drift
|
|
Less than 0.01% of rated output voltage+2mV over 30 minutes following power on.
|
|
|
||||
Sense compensation(*5)
|
|
--
|
|
|
||||
Rise response time(*6)
|
|
100mS
|
|
|
||||
Fall response time(*7)
|
Full load
|
200mS
|
|
|
||||
|
No load
|
5500mS
|
|
|
||||
Transient response time
|
|
≤2mS(Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output current. )
|
|
|
||||
Start up delay
|
|
≤6S(Turn on the power switch, the time when the power starts and enters standby mode)
|
|
|
||||
CONSTANT CURRENT MODE
|
|
|
|
|
||||
Max. Line regulation(*3)
|
|
0.05% of rated output current.
|
|
|
||||
Max. Load regulation
|
|
0.02% of rated output current+5mA.
|
|
|
||||
Ripple r.m.s. 5Hz~1MHz
|
|
≤8mA
|
|
|
||||
Temperature coefficient
|
|
70PPM/°C from rated output current, following 30 minutes warm-up.
|
|
|
||||
Temperature stability
|
|
0.01% of rated Iout over 8hrs. interval following 30 minutes warm-up. Constant line, load & temperature.
|
|
|
||||
Warm-up drift
|
|
Less than ±0.15% of rated output current over 30 minutes following power on.
|
|
|
||||
ANALOG PROGRAMMING AND MONITORING (ISOLATED FROM THE OUTPUT)
|
|
|
|
|
||||
Vout voltage programming
|
|
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: ±0.15% of rated Vout.
|
|
|
||||
Iout voltage programming
|
|
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: ±0.4% of rated Iout.
|
|
|
||||
Vout resistor programming
|
|
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: ±0.5% of rated Vout.
|
|
|
||||
Iout resistor programming
|
|
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: ±0.5% of rated Iout.
|
|
|
||||
Output voltage monitor
|
|
0~5V or 0~10V, user selectable. Accuracy: ±0.5% of rated Vout.
|
|
|
||||
Output current monitor
|
|
0~5V or 0~10V, user selectable. Accuracy: ±0.5% of rated Iout.
|
|
|
||||
Remote switch on/off
|
|
High and low level or dry contact signal control power switch
|
|
|
||||
FUNCTIONS AND FEATURES
|
|
|
|
|
||||
Series/parallel operation
|
|
Support series/parallel operation of the same specification and model to expand voltage, current and power; Parallel connection is used for automatic current sharing in master-slave operation mode.
|
|
|
||||
Constant power control
|
|
The power within the rated power range can be set to achieve constant power mode
|
|
|
||||
Output resistance control
|
|
Emulates series resistance. Resistance range: 1~1000mΩ.
|
|
|
||||
Voltage and current slope control
|
|
Programmable output rise and fall slopes. Programming range: 0.0001~999.9V/mS or A/mS
|
|
|
||||
LIST dynamic output
|
|
Four LIST program files can be saved, and each file can edit up to 200 steps of data; There are three execution modes: count, loop and single step.
|
|
|
||||
Timer function
|
|
0-9999 minutes can be set.
|
|
|
||||
Quick data storage and recall
|
|
It can store 4 groups of commonly used working data of voltage, current and other parameters, and can be quickly accessed through the digital buttons on the panel.
|
|
|
||||
Protection function
|
|
Output overvoltage protection, overcurrent protection, overload protection, over-temperature protection, short circuit protection, input undervoltage protection, overvoltage protection.
|
|
|
||||
DIGITAL PROGRAM CONTROL
|
|
|
|
|
||||
Vout programming accuracy
|
|
0.05% of rated output voltage
|
|
|
||||
Iout programming accuracy
|
|
0.2% of rated output current
|
|
|
||||
Vout programming resolution
|
|
0.002% of rated output voltage
|
|
|
||||
Iout programming resolution
|
|
0.002% of rated output current
|
|
|
||||
Vout readback accuracy
|
|
0.05% of rated output voltage
|
|
|
||||
Iout readback accuracy
|
|
0.2% of rated output current
|
|
|
||||
Vout readback resolution
|
|
0.011% F.S.
|
|
|
||||
Iout readback resolution
|
|
0.004% F.S.
|
|
|
||||
Communication interface
|
|
Built-in USB/RS-232/RS-485/CAN interface, optional LAN interface; Supports Modbus-RTU and SCPI industry standard communication protocols.
|
|
|
||||
FRONT PANEL MONITORING AND CONTROL
|
|
|
|
|
||||
Operation mode
|
|
Programmer knob,digital key and multi-function key
|
|
|
||||
Display
|
|
5 digits OLED screen displays output voltage, current, power, working status and other information; Support Chinese and English menu switching display.
|
|
|
||||
Voltage display accuracy
|
|
0.05% of rated output voltage±1count.
|
|
|
||||
Current display accuracy
|
|
0.2% of rated output current±1count.
|
|
|
||||
Voltage setting accuracy
|
|
0.05% of rated output voltage.
|
|
|
||||
Current setting accuracy
|
|
0.2% of rated output current.
|
|
|
||||
Setpoint resolution
|
|
5 digits OLED; display format: 99999, current value decreases by one digit, decimal point automatically increases by one digit, maximum resolution:1mV; 1mA.
|
|
|
||||
Display value resolution
|
|
5 digits OLED; display format: 99999, current value decreases by one digit, decimal point automatically increases by one digit, maximum resolution: 1mV; 1mA.
|
|
|
||||
ENVIRONMENT APPLICABILITY
|
|
|
|
|
||||
Operating temperature
|
|
S:Civil grade(0℃~+50℃);G:Industrial grade(-25℃~+55℃)
|
|
|
||||
Storage temperature
|
|
S:Civil grade(-20℃~+70℃);G:Industrial grade(-30℃~+85℃)
|
|
|
||||
Operating humidity
|
|
20~90% RH (no condensation).
|
|
|
||||
Storage humidity
|
|
10~95% RH (no condensation).
|
|
|
||||
Cooling
|
|
Forced air cooling by internal fans. Air flow direction: from Front panel to power supply rear.
|
|
|
||||
MECHANICAL
|
|
|
|
|
||||
Dimensions (WxHxD)
|
|
W: 420mm, H: 43.5mm, D: 443mm (Without busbars and busbars cover)
|
|
|
||||
Weight
|
|
About 6.5Kg
|
|
|
||||
NOTES
|
|
|
|
|
||||
*1:Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2:Minimum current is guaranteed to maximum 0.2% of rated output current. *3:Constant load. *4:From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense. *5:The maximum voltage on the power supply terminals must not exceed the maximum voltage. *6:From 10% to 90% or 90% to 10% of Rated Output Voltage, with rated, resistive load. *7:From 90% to 10% of Rated Output Voltage. |
|
|
|
|
DP Series Quick Selection Table
1000W series
|
|
|
|
|
||||
10V/100A/1000W
|
20V/50A/1000W
|
30V/35A/1050W
|
40V/25A/1000W
|
50V/20A/1000W
|
||||
60V/17A/1020W
|
80V/13A/1040W
|
100V/10A/1000W
|
150V/7A/1050W
|
200V/5A/1000W
|
||||
300V/3.5A/1050W
|
400V/2.5A/1000W
|
500V/2A/1000W
|
600V/1.7A/1020W
|
1000V/0.6A/600W
|
||||
1000V/1A/1000W
|
1200V/0.5A/600W
|
1500V/0.5A/750W
|
1500V/0.7A/1050W
|
2000V/0.3A/600W
|
||||
2000V/0.5A/1000W
|
2500V/0.4A/1000W
|
3000V/0.2A/600W
|
3000V/0.3A/900W
|
|
||||
1700W series
|
|
|
|
|
||||
10V/170A/1700W
|
20V/85A/1700W
|
30V/56A/1680W
|
40V/42A/1680W
|
50V/34A/1700W
|
||||
60V/28A/1680W
|
80V/21A/1680W
|
100V/17A/1700W
|
150V/11.2A/1680W
|
200V/8.5A/1700W
|
||||
300V/5.6A/1680W
|
400V/4.2A/1680W
|
500V/3.4A/1700W
|
600V/2.8A/1680W
|
1000V/1.7A/1700W
|
||||
1200V/1A/1200W
|
1200V/1.4A/1680W
|
1500V/1.1A/1650W
|
2000V/0.85A/1.7KW
|
2500V/0.68A/1.7KW
|
||||
3000V/0.55A/1650W
|
|
|
|
|
||||
2700W series
|
|
|
|
|
||||
10V/270A/2700W
|
20V/135A/2700W
|
30V/90A/2700W
|
40V/68A/2720W
|
50V/55A/2750W
|
||||
60V/45A/2700W
|
80V/34A/2720W
|
100V/27A/2700W
|
150V/18A/2700W
|
200V/14A/2800W
|
||||
300V/9A/2700W
|
400V/7A/2800W
|
500V/5.5A/2750W
|
600V/4.5A/2750W
|
1000V/2.7A/2700W
|
||||
1200V/2A/2400W
|
1500V/1.8A/2700W
|
2000V/1.4A/2800W
|
2500V/1A/2500W
|
3000V/0.9A/2700W
|
||||
3400W series
|
|
|
|
|
||||
10V/340A/3400W
|
20V/170A/3400W
|
30V/112A/3360W
|
40V/85A/3400W
|
50V/68A/3400W
|
||||
60V/56A/3360W
|
80V/42A/3360W
|
100V/34A/3400W
|
150V/23A/3450W
|
200V/17A/3400W
|
||||
300V/11.5A/3450W
|
400V/8.5A/3400W
|
500V/6.8A/3400W
|
600V/5.6A/3360W
|
1000V/3.4A/3400W
|
||||
1200V/2.8A/3360W
|
1500V/2.3A/3450W
|
2000V/1.7A/3400W
|
2500V/1.35A/3375W
|
3000V/1.1A/3300W
|
||||
5000W series
|
|
|
|
|
||||
10V/500A/5000W
|
20V/250A/5000W
|
30V/170A/5100W
|
40V/125A/5000W
|
50V/100A/5000W
|
||||
60V/85A/5100W
|
80V/65A/5200W
|
100V/50A/5000W
|
150V/34A/5100W
|
200V/25A/5000W
|
||||
300V/17A/5000W
|
400V/13A/5200W
|
500V/10A/5000W
|
600V/8.5A/5100W
|
1000V/5A/5000W
|
||||
1200V/4.2A/5040W
|
1500V/1.7A/5100W
|
2000V/2.5A/5000W
|
2500V/2A/5000W
|
3000V/1.7A/5100W
|
||||
Note:
|
|
|
|
|
||||
Please determine the model suffix letter according to the actual input voltage and temperature class requirements, when you place an order.
|
|
|
|
|
Hot Searches