* No need to cut the metal into sample, preserving the integrity of metal to be tested.
* WITH WATER TEMPERATURE COMPENSATION - AU-600K has been memoried for the water specific gravity with temperature from 0℃ to 39℃.Enter into program and make modification to finish compensation.
* WITH SOLUTION COMPENSATION - Since measuring special materials need to use other medium as testing solution,it is necessary to revise density of solution to make compensation for measuring result.
- Product Details
- {{item.text}}
Quick Details
-
Brand Name:
-
WINTESTING
-
Model Number:
-
mamd
-
Product name::
-
Metal Equipment Testing Machine Gold And Silver Tester Electronic
-
Density resolution::
-
0.001 g/cm3
-
Usage::
-
Gold Karat Detector Machine
-
Application::
-
Metal density test
-
Interface::
-
RS-232
-
Keyword::
-
Precious Metal Meter
-
Function::
-
Metal Purity Analysis
-
Standard::
-
BS.EN.ASTM
-
Minimum weight::
-
5g
-
Style::
-
Classic
Quick Details
-
Warranty:
-
1 Year
-
Power:
-
Electronic
-
Place of Origin:
-
Hebei
-
Brand Name:
-
WINTESTING
-
Model Number:
-
mamd
-
Product name::
-
Metal Equipment Testing Machine Gold And Silver Tester Electronic
-
Density resolution::
-
0.001 g/cm3
-
Usage::
-
Gold Karat Detector Machine
-
Application::
-
Metal density test
-
Interface::
-
RS-232
-
Keyword::
-
Precious Metal Meter
-
Function::
-
Metal Purity Analysis
-
Standard::
-
BS.EN.ASTM
-
Minimum weight::
-
5g
-
Style::
-
Classic
Product Display
Products Description
Title goes here.
Model
|
300K / 600K / 900K
|
120K
|
AU-1200K / AU-2000K
|
||
Style
|
Hot and Classic
|
High-precision
|
High-capacity
|
||
Maximum weight
|
300g / 600g / 900g
|
120g
|
1200g / 2000g
|
||
Weight standard deviation
|
0.005g / 0.005g /0.01g
|
0.001g
|
0.01g
|
||
Minmum measuring sample
|
4g / 4g / 5g
|
2g
|
5g
|
||
Reference weight
|
|
|
|
||
Density resolution
|
0.001g/cm3
|
0.001g/cm3
|
0.001g/cm3
|
||
Sink size
|
Length15.3 cm×width10.7 cm×height9.3cm
|
|
Length20.3 cm×width15.7 cm×height11.3cm
|
||
Measuring function
|
(1)karat value,percentage content,density for gold
|
|
|
||
|
(2)PT value,percentage content,density for platinum
|
|
|
||
|
(3)S value,percentage content,density for silver
|
|
|
||
|
(4)percentage content,density for other alloy.
|
|
|
||
Gold K value
|
(9 ,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24)K &content percentage %
|
|
|
||
Platinum
|
PT600 ,PT650,PT700,PT750,PT800,PT850,PT900,PT950,PT1000 & content percentage %
|
|
|
||
Silver
|
S600 ,S650,S700,S750,S800,S850,S900,S950,S1000 & content %
|
|
|
||
Measuring principle
|
Archimedes buoyancy method
|
|
|
||
Measuring time
|
About 5 to 20 seconds
|
|
|
||
Measuring procedure
|
(1)Measure the weight in air firstly,press ENTER button.
|
|
|
||
|
(2)Place the sample into water to measure weight in water.Press ENTER
|
|
|
||
|
button.display result.
|
|
|
||
Parameter setting
|
Water temperature setting,measuring medium density setting,air density setting,main materials and secondary materials density
setting,copper-silver proportion setting |
|
|
||
Copper-silver proportion range
|
can be shifted cyclically with 9/1,8/2,7/3,6/4,5/5,4/6,3/7,2/8,1/9.the default setting is 7/3.
|
|
|
||
Calibration method
|
Single button calibration,automatic testing
|
|
|
||
Standard accessories
|
(1)Host,(2)Sink,(3)Measuring plate,(4)Tweezers,(5)Thermometer,(6)weight,(7)windproof dustproof cover(8)One set of measuring gold
dust accessories(9)Power supply |
|
|
||
Data interface
|
Standard RS-232 interface
|
|
|
||
Optional accessories
|
AU-40 printer,AU-40A data connecting line
|
|
|
||
Power supply
|
Defaulted as AC100V~240V 50HZ/60HZ Europe standard; based on customers' requirement.
|
|
|
||
Gross weight/size
|
4.3kg/ Length 42.5 cm× width 17.5 cm×height 32.5cm
|
|
|
||
|
(no including weights)
|
|
|
Hot Searches