- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
Goodwe
-
Model Number:
-
Goodwe-GW5/6.5/8/10K-ET
-
Output Frequency:
-
50Hz/60Hz
-
Size:
-
516*415*180mm
-
Certificate:
-
CE/UL
-
Warranty:
-
5 Years/10 Years
-
Weight:
-
24kg
-
No. of MPP Trackers:
-
2
-
Start-up Voltage (V):
-
180
-
Nominal Battery Voltage (V):
-
180~600
-
Max. DC Input Voltage (V):
-
1000
Quick Details
-
Output Type:
-
Triple
-
Type:
-
Hybrid Inverter
-
Inverter Efficiency:
-
21.7%
-
Place of Origin:
-
Jiangsu, China
-
Brand Name:
-
Goodwe
-
Model Number:
-
Goodwe-GW5/6.5/8/10K-ET
-
Output Frequency:
-
50Hz/60Hz
-
Size:
-
516*415*180mm
-
Certificate:
-
CE/UL
-
Warranty:
-
5 Years/10 Years
-
Weight:
-
24kg
-
No. of MPP Trackers:
-
2
-
Start-up Voltage (V):
-
180
-
Nominal Battery Voltage (V):
-
180~600
-
Max. DC Input Voltage (V):
-
1000
Product Description
Datasheet
Model
|
GW5K-ET
|
GW8K-ET
|
GW10K-ET
|
|||
Battery Input Data
|
|
|
|
|||
Battery Type
|
Li-Ion
|
|
|
|||
Battery Voltage Range (V)
|
180~600
|
|
|
|||
Max. Charging Current (A)
|
25
|
|
|
|||
Max. Discharging Current (A)
|
25
|
|
|
|||
Charging Strategy for Li-Ion Battery
|
Self-adaption to BMS
|
|
|
|||
PV String Input Data
|
|
|
|
|||
Max. DC Input Power (W)
|
6500
|
9600
|
13000
|
|||
Max. DC Input Voltage (V)*1
|
1000
|
|
|
|||
MPPT Range (V)*2
|
200~850
|
|
|
|||
Start-up Voltage (V)
|
180
|
|
|
|||
MPPT Range for Full Load (V)*3
|
240~850
|
|
|
|||
Nominal DC Input Voltage (V)*4
|
620
|
|
|
|||
Max. Input Current (A)
|
12.5/12.5
|
|
|
|||
Max. Short Current (A)
|
15.2/15.2
|
|
|
|||
No. of MPP Trackers
|
2
|
|
|
|||
No. of Strings per MPP Tracker
|
1/1
|
|
|
|||
AC Output Data (On-grid)
|
|
|
|
|||
Nominal Apparent Power Output to Utility Grid (VA)
|
5000
|
8000
|
10000
|
|||
Max. Apparent Power Output to Utility Grid (VA)*5
|
5000
|
8800
|
11000
|
|||
Max. Apparent Power from Utility Grid(VA)
|
10000
|
15000
|
15000
|
|||
Nominal Output Voltage (V)
|
400/380, 3L/N/PE
|
|
|
|||
Nominal Output Freqency (Hz)
|
50/60
|
|
|
|||
Max. AC Current Output to Utility Grid (A)
|
8.5
|
13.5
|
16.5
|
|||
Max. AC Current From Utility Grid (A)
|
32
|
40
|
45
|
|||
Output Power Factor
|
~1(Adjustable from 0.8 leading to 0.8 lagging)
|
|
|
|||
Output THDi (@Nominal Output)
|
<3%
|
|
|
|||
AC Output Data (Back-up)
|
|
|
|
|||
Max. Output Apparent Power (VA)
|
5000
|
8000
|
10000
|
|||
Peak Output Apparent Power (VA)*6
|
10000, 60sec
|
16000, 60sec
|
16500, 60sec
|
|||
Max. Output Current (A)
|
8.5
|
13.5
|
16.5
|
|||
Nominal Output Voltage (V)
|
400/380
|
|
|
|||
Nominal Output Freqency (Hz)
|
50/60
|
|
|
|||
Output THDv (@Linear Load)
|
<3%
|
|
|
|||
Efficiency
|
|
|
|
|||
Max. Efficiency
|
98.0%
|
98.2%
|
|
|||
Max. Battery to Load Efficiency
|
97.5%
|
|
|
|||
Euro Efficiency
|
97.5%
|
|
|
|||
MPPT Efficiency
|
99.9%
|
|
|
|||
Protection
|
|
|
|
|||
Anti-islanding Protection
|
Integrated
|
|
|
|||
PV String Input Reverse Polarity Protection
|
Integrated
|
|
|
|||
Insulation Resistor Detection
|
Integrated
|
|
|
|||
Residual Current Monitoring Unit
|
Integrated
|
|
|
|||
Output Over Current Protection
|
Integrated
|
|
|
|||
Output Short Protection
|
Integrated
|
|
|
|||
Battery Input Reverse Polarity Protection
|
Integrated
|
|
|
|||
Output Over Voltage Protection
|
Integrated
|
|
|
|||
General Data
|
|
|
|
|||
Operating Temperature Range (°C)
|
-35~60
|
|
|
|||
Relative Humidity
|
0~95%
|
|
|
|||
Operating Altitude (m)
|
≤4000
|
|
|
|||
Cooling
|
Natural Convection
|
|
|
|||
Noise (dB)
|
<30
|
|
|
|||
User Interface
|
LED & APP
|
|
|
|||
Communication with BMS
|
RS485; CAN
|
|
|
|||
Communication with Meter
|
RS485
|
|
|
|||
Communication with EMS
|
RS485 (Insulated)
|
|
|
|||
Communication with Portal
|
Wi-Fi
|
|
|
|||
Weight (kg)
|
24
|
|
|
|||
Size (Width*Height*Depth mm)
|
516*415*180
|
|
|
|||
Mounting
|
Wall Bracket
|
|
|
|||
Protection Degree
|
IP65
|
|
|
|||
Standby Self Consumption (W)*7
|
<15
|
|
|
|||
Topology
|
Transformerless
|
|
|
|||
Certifications & Standards
|
|
|
|
|||
Grid Regulation
|
CEI 0-21; VDE4105-AR-N; VDE0126-1-1; EN50438; G83/2; G100
|
|
|
|||
Safety Regulation
|
IEC62109-1&2
|
|
|
|||
EMC
|
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-4-16, EN61000-4-18, EN61000-4-29
|
|
|
*1For 1000V system, Maximum operating voltage is 950V. For AustraliaL safty, there will be a warning if PV voltage > 600V
*2 For AustraliaL safty, MPPT range is 200~550V
*3 For AustraliaL safty, MPPT voltage upper limit is 550V
*4 For AustraliaL safty, nominal DC input voltage is 450V
*5 According to the local grid regulation
*6 Can be reached only if PV and battery power is enough
*7 No Back-up Output
*2 For AustraliaL safty, MPPT range is 200~550V
*3 For AustraliaL safty, MPPT voltage upper limit is 550V
*4 For AustraliaL safty, nominal DC input voltage is 450V
*5 According to the local grid regulation
*6 Can be reached only if PV and battery power is enough
*7 No Back-up Output
Wiring order & Accessories
Construction case
Certificate
Product packaging
FAQ
1. Who are we?
We are a professional manufacturer on Solar Panel with many years experience. Our factory and business office located in Wuxi City, Jiangsu Province.
2. What can we provide?
We can provide solar panel,solar inverter,solar energy system.
3. Why choose us?
A.Higher power generation
B.Competitive price
C.High quality standard
D.Customized service
4. What services can we provide?
Accepted Delivery Terms: FOB,CIF,EXW,FAS,CIP,FCA,DDP,DDU;
Accepted Payment Currency:USD,EUR,CNY;
Accepted Payment Type: T/T,L/C,PayPal,Western Union,Cash.
Hot Searches