FOB Reference Price: Get Latest Price
≥10 Pieces
US $2
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Model Number:
HDSS16823
Usage:
smoke detector
Theory:
Current Sensor
Output:
Switching Transducer
Certificate:
BRE LPCB EN54-7 C
Material:
Double Sided Glass
Design Patent No:
201130310516.3
Guarantee period:
2 years
Power::
DC10-30 V
Key word:
cigarette smoke detector
manufacturer:
factory price

Quick Details

Special Features:
Remote Control
Place of Origin:
Fujian, China
Brand Name:
hengdun
Model Number:
HDSS16823
Usage:
smoke detector
Theory:
Current Sensor
Output:
Switching Transducer
Certificate:
BRE LPCB EN54-7 C
Material:
Double Sided Glass
Design Patent No:
201130310516.3
Guarantee period:
2 years
Power::
DC10-30 V
Key word:
cigarette smoke detector
manufacturer:
factory price
Product Description

1. cigarette smoke detector

1, power supply: DC9V cascading battery making (6)
2, sensitivity: 0.16 (light reduction coefficient m value)
3, monitoring current: < 15 ua, fire current: < 17 ma
4, indicator light: three color light, the green is normal, red fire, yellow for failure
5, alarm volume: > 80 db front (3 m)
6, protection area: 40 m2 or specific parameters reference specifications for design of automatic fire alarm system (GB50116-1998)
7, using the environment temperature: - 10 ℃ to + 50 ℃ relative humidity: 95% or less (40 ℃, no condensation)
8, use fixed number of year: > 10 years
9, appearance size: 107 mm diameter, high 44 mm
10, shell material, color: white ABS
11, weight: 136 g
12, mounting holes distance: 78 mm

2. GSM SMOKE DETECTOR WITH SIM CARD

1. SOS Alarm

This device can send SMS for SOS alarm.

Pressing the SOS button, the alarm LED turns on, and the buzzer starts ringing (the default ring time is 3 minutes). Then the device send alarm SMS to preset main number. Press this button again will stop the buzzer, and the device return to the previous status before alarm.

Alarm SMS numbers (max. 5 groups), main number (1 group) and the SMS content could all be set by users themselves. (Please check “System Settings” below for detailed setting method.) Default SMS is “Fire Emergency”.

2. Smoke Alarm

The smoke detecting of this device is base on photoelectric technology. When it detects smoke, it will make call and send SMS to the preset phone numbers.

If there’s trigger again within 3 minutes after the first alarm, this device will not send alarm signal. And within the 3 minutes, if the user press SOS button, or arm the device by SMS, the buzzer will stop ringing, and the device can return detecting 1min 40sec later.

After sending the alarm SMS, the device will turn to arm status automatically.

3. Reset

Keep pressing the SOS button for 5 seconds, (loose it until the buzzer makes a long beep), the device will come to factory reset status. All settings will return to default.

Operation Guidance

1. Insert a SIM card into the card slot. Make sure that the SIM card has enough balance to make call and send SMS.

2. Connect the power adaptor. The LED indicator will be on for about 10 seconds and the device starts self-check. If it detects the SIM card, the buzzer will make two long beeps; and if not, it will make four short beeps. If the indicator flashes every two seconds, it means the main number hasn’t been set; if it keeps flashing quickly, it means main number been set but SIM card not detected.

3. To make sure that all the settings are in default before using, you could make reset.

4. Set main number. Only this number could do settings to the smoke alarm device.

5. Now you could do other settings and put this device into use.

6. During the whole working status, this device would check the GSM network. Then the GSM signal is less than 20% (not strong enough to make call and send SMS), the alarm LED will keep flashing quickly as mentioned above. At this time, you should change the place of the device until the signal LED comes into normal.

7. This device has power off/ recovery alert function. When the external power is disconnected, it will be powered by the backup battery, and send a SMS “Power charger off”. And the SMS for external power recovery is “Power charger on”.

3.WIRE SMOKE DETECTOR

Main Features:

Power supply non-polar input

Infrared photoelectric sensor

MCU processing, eliminate false alarm

SMT manufacture technology, high stability

Dustproof, mothproof, anti-light interference design

Stainless steel shield, anti-RFI(20V/m-1GHz)

Execute criterion:UL268, GB4715, EN54-7

Technical specification:

Model No.

SR-801PC-2/SR-802PC-2/SR-811PC-2

SR-801PC-4/SR-802PC-4/SR-811PC-4:

Operating voltage

DC9~35V

Static current

55uA

12mA(NC);500uA(NO)

Alarm current

35mA@DC12V;60mA@DC24V

10mA(NC);18mA(NO)

Sensitivity

0.5dB/m(±0.01dB/M)

0.5dB/m(±0.01dB/M)

Alarm output

Remote LED indicator

Relay output

Installation

Ceiling mounted

Ceiling mounted

Working environment

-10℃~+50℃(≤95%RH No congelation)

-10℃~+50℃(≤95%RH No congelation)

Dimension

104*49mm (SR-801/SR-802)

100*48mm (SR-811)

4.STAND-ALONE SMOKE DETECTOR

Power supply

9V DC Block battery/PP3

Static current

≤10µA

Alarm current

16mA

Humidity

0to95%(40±2°C),no condensing or icing

Quiescent current

8µA

Operating temperature

minus10°C to 50°C

Alarm decibel

≥85dB at 10feet(3 meters)

Test button

To verify the proper functioning of smoke

alarm

Smoke sensitivity

0.086 dB/m to 0.140 dB/m

Low voltage warning

Smoke alarm beeps every 40 seconds

for 30 days (minimum) to indicate a

need of battery replacement

5 .STAND-ALONE SMOKE DETECTOR

1.Easy to install with mounting hardware included

2. 9 Volt battery included

3.Suitable for any room  Test button for easy recommended monthly testing

4. Low battery signal

5. To protect you,a safety clip will not allow mounting of smoke alarm without 9 Volt battery installed

6. Ionization chamber for early detection from all directions

7.Loud 85db alarm signal

power:9vdc

working current: static state current<200uA

working current:≤20uA

buzzer sound level:85dB in distance 20 inches

Alarm indication:red LED

working temperature:-10℃~+50℃

Environmental humidity:≤95%RH

Alarm method:relay open/closed

Size:107*35mm

6 . STAND-ALONE PHOTOELECTRIC SMOKE DETECTOR

1) Material: ABS plastic

2) Assembly no wiring, size: Dia.104xH35mm
3) Power supply:9V carbon zinc battery/PP3(battery included)
4) Standby current: 8μA, Alarm current: 16mA
5) Environment temperature: -10°C ~ +50°C
6) Environment humidity: 0 to 95%(40±2°C)
7) Alarm decibel: louder than 85dB at 10feet(3 meters)
8) Tamper Resist locking pin
9) Test button:To verify the proper functioning of the detector
10)Low voltage warning: Unit beeps every 40 seconds for 30 days (minimum) to indicate a need of battery replacement
11)Smoke sensitivity:Conform to EN 14604 standard
12)CE, ROHS, EN 14604
13)5 years quality guarantee

7.STAND-ALONE SMOKE DETECTOR(CURRENT AND BATTERY BACK UP)

1.power:12/24VDC/9VDC

2.working current: static state current<5uA,

3.working current:20-40mA

4.alarm temperature:standard50-70℃

5.Environmental humidity:10-90%RH

6.buzzer sound level:85dB in distance 10 inches

8. Conventional Smoke Detector

1.power:DC-9V-28V
2.Environmental humidity:≤95%RH(40℃±2℃)
3.≤60µA @ 24 VDC
4.≤30mA @ 24 VDC
5.buzzer sound level:85dB in distance 3ms

Company
contact

APP
Post My RFQ
WhatsApp
+86-17326049340