- Product Details
- {{item.text}}
Quick Details
-
Product name:
-
2540 Seawater RO membrane
-
Application:
-
Seawater Desalination
-
Model:
-
SW11-2540
-
Brand:
-
Vontron
-
weight:
-
4kg
Quick Details
-
Core Components:
-
Sea Water Reverse Osmosis Membrane
-
Place of Origin:
-
China
-
Weight (KG):
-
4 kg
-
Product name:
-
2540 Seawater RO membrane
-
Application:
-
Seawater Desalination
-
Model:
-
SW11-2540
-
Brand:
-
Vontron
-
weight:
-
4kg
Product Description
SW11-2540 Vontron SW RO membrane Element 2540 Sea Water Reverse Osmosis Membrane
Seawater Desalination
Membrane
for Sea Water Treatment Plant
Extra Low Pressure Element - XLP Series
Suitable for desalting those water sources with low salinity while not requiring high salt rejection, with salt concentration lower than 1000 ppm
|
|
|
|
|
|
|||||
Model
|
Stable Rejection(%)
|
Average Permeate
GPD (m3/d) |
Testing Pressure
psi (MPa) |
Testing Solution
Concentration NaCl (ppm) |
Recovery
(%) |
|||||
XLP11-4040
|
98
|
2000 (7.6)
|
100 (0.69)
|
500
|
15
|
|||||
XLP12-8040
|
98.0
|
9000(34.6)
|
|
|
|
|||||
Ultra Low Pressure Element – ULP Series
Suitable for desalting those water sources with salt concentration lower than 2000 ppm,
such as surface water, underground water, tap water and municipal water, etc |
|
|
|
|
|
|||||
Model
|
Stable Rejection(%)
|
Average
Permeate GPD (m3/d) |
Testing Pressure
psi (MPa) |
Testing Solution
Concentration NaCl (ppm) |
Recovery
(%) |
|||||
ULP21-2521
|
99.0
|
300 (1.13)
|
150 (1.03)
|
1500
|
8
|
|||||
ULP21-2540
|
99.0
|
750 (2.84)
|
|
|
15
|
|||||
ULP21-4021
|
99.0
|
950 (3.2)
|
|
|
8
|
|||||
ULP31-4021
|
99.4
|
850 (3.2)
|
|
|
8
|
|||||
ULP31-4040
|
99.4
|
1900 (7.2)
|
|
|
8
|
|||||
ULP21-4040
|
99.0
|
2400 (9.1)
|
|
|
8
|
|||||
ULP22-8040
|
99.0
|
12100 (45.7)
|
|
|
8
|
|||||
ULP32-8040
|
99.5
|
10500 (39.7)
|
|
|
8
|
|||||
Low Pressure Element - LP Series
Suitable for desalting surface water, underground water, tap water and municipal water, etc. with salinity under 10000ppm.
|
|
|
|
|
|
|||||
Model
|
Stable Rejection(%)
|
Average
Permeate GPD (m3/d) |
Testing Pressure
psi (MPa) |
Testing Solution
Concentration NaCl (ppm) |
Recovery
(%) |
|||||
LP21-4040
|
99.5
|
2400 (9.1)
|
225 (1.55)
|
2000
|
15
|
|||||
LP22-8040
|
99.5
|
10500 (39.7)
|
|
|
|
|||||
Nanofiltration Membranes
Nanofiltration membranes are designed for removing from water various organics, microbes, viruses and most metallic ions with two or higher valence while retaining part of the sodium, potassium, calcium and magnesium ions, etc
|
|
|
|
|
|
|||||
Model
|
Stable Rejection(%)
|
Average
Permeate GPD (m3/d) |
Testing Pressure
psi (MPa) |
Testing Solution
Concentration NaCl (ppm) |
Recovery
(%) |
|||||
VNF1-2540
|
30 ~ 50
|
800(3.03)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
> 96
|
650(2.46)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
VNF2-2540
|
90 ~ 98
|
700(2.65)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
> 96
|
700(2.65)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
VNF2-4021
|
98
|
2000(7. 5)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
96
|
2000(7.5)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
VNF1-4040
|
30 ~ 50
|
2400(9.1)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
> 96
|
2000(7.5)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
VNF2-4040
|
90 ~ 98
|
2000(7.5)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
> 96
|
2000(7.5)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
VNF1-8040
|
30 ~ 50
|
1200(45.5)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
> 96
|
10000(37.9)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
VNF2-8040
|
90 ~ 98
|
1000(37.9)
|
100 (0.69)
|
2000ppm (MgSO4)
|
15
|
|||||
|
> 96
|
10000(37.9)
|
100 (0.69)
|
2000ppm (NaCl)
|
15
|
|||||
Fouling Resistant Element - FR Series
The FR series is suitable for wastewater reclamation application and treatment of high-polluted water sources thanks to its strengthened anti-scaling performance and higher resistance to organic and microbial fouling which can decrease the fouling speed and extend the service life of membrane element
|
|
|
|
|
|
|||||
Model
|
Stable Rejection(%)
|
Average
Permeate
GPD (m3/d) |
Testing Pressure
psi (MPa) |
Testing Solution
Concentration NaCl (ppm) |
Recovery
(%) |
|||||
FR11-4040
|
99.5
|
2200 (8.3)
|
225 (1.55)
|
2000
|
15
|
|||||
FR12-8040
|
99.5
|
10500 (39.7)
|
|
|
|
|||||
Seawater Desalination Element – SW Series
Applicable to treatment of seawater and high- concentration brackish water
|
|
|
|
|
|
|||||
SW8040LE400
|
99.8
|
9000 (34.1)
|
800 (5.5)
|
32800
|
8
|
|||||
SW8040XHR-400
|
99.85
|
6000 (22.7)
|
|
|
8
|
|||||
SW8040HR-400
|
99.8
|
7500 (28.4)
|
|
|
8
|
|||||
SW8040HR-440
|
99.8
|
8250(31.0)
|
|
|
8
|
|||||
SW22-8040
|
99.7
|
6000(22.7)
|
|
|
8
|
|||||
SW4040LE
|
99.7
|
1900 (7.2)
|
|
|
8
|
|||||
SW4040HR
|
99.8
|
1600 (6.1)
|
|
|
8
|
|||||
SW21-4040
|
99.5
|
1400(5.3)
|
|
|
8
|
|||||
SW11-4021
|
99.5
|
750 (2.8)
|
|
|
4
|
|||||
SW11-2540
|
99.5
|
600 (2.3)
|
|
|
8
|
|||||
SW11-2521
|
99.5
|
270 (1.0)
|
|
|
4
|
|||||
High Oxidation Resistant Membranes
The HOR series has the excellent properties that can remain basically unchanged through continuous impact of 1880ppm oxidative matters for 30 hours. It can endure a transient oxidative impact of NaClO at 26000ppm•hwhile the rejection rate remains above 98%
|
|
|
|
|
|
|||||
Model
|
Stable Rejection(%)
|
Average
Permeate GPD (m3/d) |
Testing Pressure
psi (MPa) |
Testing Solution
Concentration NaCl (ppm) |
Recovery
(%) |
|||||
HOR21-4040
|
99.5
|
9000 (34.1)
|
225 (1.55)
|
2000
|
15
|
|||||
HOR22-8040
|
99.5
|
2200 (8.3)
|
|
|
|
Ro Membranes we Seller
VONTRON RO System
Nitto Hydranautics Ro System
DOW Ro System
FROTEC Ro System
RUNMO Ro System
Tanfo
Ro System
HuaMO Ro System
HID
Ro System
Vontron Ro System
HuaMo Ro System
Support customization and OEM
Contact US TO Know More
+8619182196912
Packing & Delivery
Export Carton Packing
Customerized Packages
Hot Searches