Products
30162.29 High quality Gas Pressure Sensor
30162.29 High quality Gas Pressure Sensor

30162.29 High quality Gas Pressure Sensor

FOB Reference Price: Get Latest Price
≥1 Pieces
US $30
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Mounting Type:
other
Description:
other, other
Manufacturing Date Code:
other
Model Number:
30162.29
Place of Origin:
Zhejiang, China
Brand Name:
Kelsun
Theory:
other
Output:
other
Sensor:
Gas Pressure Sensor
Measuring range:
0~700kPa
Resolution:
0.025kPa
Accuracy:
±0.5kPa

Quick Details

Use:
other
Series:
other
Features:
other
Mounting Type:
other
Description:
other, other
Manufacturing Date Code:
other
Model Number:
30162.29
Place of Origin:
Zhejiang, China
Brand Name:
Kelsun
Theory:
other
Output:
other
Sensor:
Gas Pressure Sensor
Measuring range:
0~700kPa
Resolution:
0.025kPa
Accuracy:
±0.5kPa
Product Description

Datalogger,TriE Smart

Art No. 30160.11

Portable datalogger with superelevation performance-to-price ratio
TriE Smart is a fully self-contained portable datalogger, which can be used as:
1. A device connected to a computer
2. A stand-alone instrument
Under the stand-alone mode, Smart can:
1. Display the meter readings of the sensor attached
2. Support for data storage, and support for exporting the stored data to a computer

K-Type Temperature(thermocouple sensor)

Art No. 30162.01

Measuring range:-25℃~+100℃
resolution:0.03℃
Accuracy:±0.5℃
Typical Experiment
Cooling water naturally
Liquid's evaporation cooling
Charkes's Law
Change its work and temperature of compressed air

Experimental Apparatus
Datalogger
Quick-temperature sensor
A-type baseplate
Syringe
Florence flask
Perforated rubber stopper

Micro Voltage

Art No. 30162.02

Measuring range:-60mV~+60mV
Resolution:0.03mV
Accuracy:±0.5mV
Internal resistance:1MΩ
Typical Experiment
Lenz's Law
Electromagnetic induction
Faraday's of electromagnetic induction

Experimental Apparatus
Datalogger
Micro voltage sensor Magnetic field sensor
Faraday's law of electromagnetic induction experimenter

Voltage sensor

Art No. 30162.03

Measuring range:-25V~+25V
resolution:0.01V
Accuracy:±0.01V
The voltage sensor is used to measure the electric
potential difference at both ends of the electrical
equipments or circulars.after the circuit of voltage it
collects.then it can realize the measurement.The
voltage sensor can be used in the DC circuit and low
voltage AC circuit.
Typical Experiment
Measure the electrodynamic potential and internal
resistance of power supply
Measure the VA characteristic curve of small bulb,
diode,conductor
Ohm's Law
Serial-parallel circuit of resistance
Electromagnetic induction phenomena and induced
current
LC oscillation
Serial-parallel circuit.charging and discharging of
capacitor

Experiment Equipment
DIS-EX05 LC oscillation circuit
Datalogger
Voltage sensor
Student power supply

Voltage sensor

Art No. 30162.04

Measuring range:-20V~20V -2V~2V -200mV~
200mV
resolution:0.01V 0.001V 0.1mV
Accuracy:±0.01V ±0.01V ±0.5mV
Typical Experiment
Measure the electrodynamic potential and internal
resistance of battery
VA characteristics of small bulb,diode and conductor
Ohm's Law
Serial-parallel circuit of resistance
Electromagnetic induction phenomena
Serial-parallel circuit,charging-discharging of capacitor

Experiment Equipment
Datalogger
Multirange voltage sensor Milli current sensor
DIS-EX12 Measure the electrodynamic potential and
internal resistance of battery circuit
Sliding rheostat

PH meter sensor

Art No. 30162.05

Measuring range:0~14
Resolution:0.003
Accuracy:±0.1
Typical Experiment
Acid-base neutralization titration
pH value of different solutions
Acidity of phenol
Mechanism of organism for maintaining pH stability
Study on impact of pH value on pectinase activity

Experimental Apparatus
Datalogger
pH sensor
Beaker

G-M sensor

Art No. 30162.06
Measuring range:0~40000c/min
Typical Experiment
Measurement on common radioactive source counting rate
Measurement on background counting rate
Radioactive shield
Study the relation between radioactive intensity and distance
Measurement on radioactivity of building materials

Experimental Apparatus
Datalogger
G-M sensor
Iron stand
Radioactive source for teaching

Carbon dioxide sensor

Art No. 30162.07
Measuring range: 0 ~100000PPm
Resolution: 2ppm
Accuracy: (0~5000ppm) 3%
(5000~50000ppm) 4%
(50000~100000ppm) 6%
Typical Experiment
Photosynthesis of plant
Study the breathing way of saccharomycetes
Assessment on air quality
Generation velocity of CO2 gas in chemical reaction

Experimental Apparatus
Datalogger
CO2 sensor
Conical flask
Na2CO powder
Diluted HCI solution
Spoon

Sulfur dioxide sensor

Art No. 30162.08
Measuring range:0.000~20.000ppm
Resolution:0.005ppm
Accuracy:±0.1ppm
Typical Experiment
Air quality assessment
Detection of vehicle exhaust
Measure the small quantity of sulphur dioxide generated
by chemical reaction
Trace sodium thiosulfate solution react with concentrated
sulfuric acid

Experimental Apparatus
Datalogger
Sulphur dioxide sensor
Gas bottle

Humidity sensor

Art No. 30162.09
Measuring range:0~100%RH
Resolution:1%RH
Accuracy:0.02%
Typical Experiment
Measurement on the change of environmental humidity
Hydroscopicity of the concentrated sulfuric acid
Design and make an ecological cylinder and observe
its stability

Experimental Apparatus
Datalogger
Humidity sensor
Iron stand
Dovetail clamp
Multi-directional adapter
Test tube

Colorimeter

Art No. 30162.10
Measuring range: 0~100%
Resolution: 0.02%
Accuracy: ±0.2%

Typical Experiment
Impact of concentration on reaction velocity - color - fading
reaction of potassium permanganate and oxalic acid
Impact of temperature on reaction velocity - reaction of
sodium thiosulfate and sulfuric acid
Measurements on the content of Vitamin C in juice
Measurement on concentration of substance in
solution(Beer-Lambert law)
Experimental Apparatus
Datalogger
Colorimeter
Beaker

Current sensor

Art No. 30162.11
Measuring range: -20mA~+20mA
Resolution: 0.01mA
Accuracy: ±0.1mA

Typical Experiment
Charge and discharge the capacitor
Experimental Apparatus
Smart Datalogger
Electrical Experiment Board
Student Power Supply

Current sensor

Art No. 30162.12
Measuring range:-3.0A~+3.0A
Resolution:0.001A
Accuracy:±0.001A
Typical Experiment
Measure the electrodynamic potential and internal
resistance of battery
Measure the VA characteristic curve of small bulb,
diode,conductor
Ohm's Law
Serial-parallel circuit of resistance

Experimental Apparatus
DIS-EX12 Measure the electrodynamic potential and
internal resistance of battery circuit
Datalogger
Voltage sensor Current sensor
Sliding rheostat
Student power supply

Current sensor

Art No. 30162.13
Measuring range:-2A~2A -200mA~200mA
-20mA~20mA
Resolution:0.001A 0.1mA 0.01mA
Accuracy:±0.05A ±0.5mA ±0.05mA
Typical Experiment
Measure the electrodynamic potential and internal resistance
of battery
VA characteristics of small bulb,diode and conductor
Ohm's Law
Serial-parallel circuit of resistance
Electromagnetic induction phenomena
LC oscillation
Serial-parallel circuit,charging-discharging of capacitor

Experimental Apparatus
Datalogger
Multirange current sensor Voltage sensor
DIS-EX07 VA characteristics of conductor
Sliding rheostat
Student power supply

Micro-current sensor

Art No. 30162.14
Measuring range: -10μA~+10μA
Resolution: 0.01μA
Accuracy: ±0.1μA
Typical Experiment
Electromagnetic induction phenomena
Thermoelectric current phenomena
Voltaic cell

Experimental Apparatus
DIS-EX25 Electromagnetic induction phenomena circuit
Sbarmagnet
Datalogger
Micro current sensor

ORP(oxygen reduction sensor)

Art No. 30162.15
Measuring range:-2000mV~+2000mV
Resolution:1mV
Accuracy:±5mV
Typical Experiment
Detection of industrial wastewater
Sterilization of water and its application
Water quality testing

Experimental Apparatus
Datalogger
Oxidation-reduction sensor
Iron stand
Beaker

Oxygen sensor

Art No. 30162.16
Measuring range: 0~100%
Resolution: 0.02%
Accuracy: ±0.2%
Typical Experiment
Photosynthesis of plant
Compare the decomposition of catalase in different
conditions
Compare the gas exhaled by human with the
environmental gas

Experimental Apparatus
Datalogger
Oxygen sensor CO2 sensor
Breathing mouthpiece
Airflow head

Force sensor

Art No. 30162.17
Measuring range: -50N~+50N
Resolution: 0.01N
Accuracy: ±0.05N
Typical Experiment
Hooke's Law
Newton's Third Law
Theorem of momentum
Metal expands with heat and contracts with cold
Explore the simple harmonic motion
Overweight and weightlessness
Archimedes' Law

Experimental Apparatus
Newton's third law experimenter
Datalogger
Force sensor

Magnetic field sensor

Art No. 30162.18
Range: 64mT~+64mT
Resolution: 0.03mT
Accuracy: 0.03mT
Typical Experiment
Study the magnetic field around the permanent magnet
Measure the axial magnetic field of electrified solenoid
Measure the magnetic field around the electrified wire
Measure the magnetic field of Helmholtz coil

Experimental Apparatus
Datalogger
Magnetic field sensor
Solenoid
Student power supply
Sliding rheostat

Motion sensor

Art No. 30162.19
Measuring range: 20cm~200cm
Resolution: 0.1cm
Typical Experiment
Explore the simple harmonic motion
Forced vibration
Uniform linear motion,uniform variable rectilinear motion

Experimental Apparatus
Datalogger
Motion sensor
Car &rail experimental device

Motion sensor

Art No. 30162.20
TS2117 Range: 40cm~600cm
Resolution: 1mm

Photogate sensor

Art No. 30162.21
Measuring range: 0~∞s
Resolution: 0.01ms
Typical Experiment
Newton's Second Law
Study the pendulum movement
Theorem of momentum
Mechanical Energy Conservation Law
Measure the rotating speed of rotating objects
Study of centripetal force
Study of Atwood machine

Experimental Apparatus
Datalogger
Photogate sensor
Car &rail experimental device

Dissolved oxygen sensor

Art No. 30162.22
Measuring range: 0~20mg/L
Resolution: 0.005mg/L
Accuracy: ±0.2mg/L
Typical Experiment
Study the breathing way of saccharomycetes
Study the dissolved oxygen of different water
Factors that affect plant photosynthesis

Experimental Apparatus
Datalogger
Dissolved oxygen sensor
Photosynthesis experiment box
Lamp

Temperature Sensor

Art No. 30162.23
Measuring range: -50℃~150℃
Resolution: 0.05℃
Accuracy: ±0.5℃
Typical Experiment
Cooling water naturally
Liquid's evaporation cooling
Work-to-internal energy conversion
Study the relation between liquid boiling point and pressure
Study the thermoelectricity phenomena
The comparison of different material's heat conduction
performance
The convex lens convergence effect

Experimental Apparatus
Convex lens' ray convergence experimenter
Datalogger
Temperature sensor
Light source

High-Temperature Sensor

Art No. 30162.24
Measuring range: -200℃~1200℃
Resolution: 0.3℃
Accuracy: ±0.1℃
Typical Experiment
Study on the melting point of crystal
Measurement on temperature of flame
Liquid cooling via evaporation
Study on relation between boiling point and pressure of liquid
Study on the thermoelectricity phenomenon
Comparison on heat conduction performance of different
substances

Experimental Apparatus
Datalogger
Hight temperature sensor
Alcohol lamp

Surface Temperature Sensor

Art No. 30162.25
Measuring range: -30℃~150℃
Resolution: 0.05℃
Accuracy: ±0.5℃
Typical Experiment
The conversion between power and energy
comparison on thermal conductivity of different objects

Experimental Apparatus
Datalogger
Surface temperature sensor
Friction working experimenter
Cotton string

Sound Sensor

Art No. 30162.26
Low range: 30~90dB
Resolution: 0.1dB
High range: 80~120dB
Resolution: 0.1dB
Sound wave
Measuring range:20Hz~20kHz
Typical Experiment
Measure the level of sound intensity
Measure the environmental intensity of noise
Measure the velocity of sound in the air
Synthesis of sound wave

Experimental Apparatus
Datalogger
Sound sensor
Tuning fork

Acceleration Sensor

Art No. 30162.27
Measuring range: -6g~6g
Resolution: 0.003g
Accuracy: ±0.01g
Typical Experiment
Study the Newton's Law of Motion
Study the centripetal acceleration
Explore the resonance phenomena
Study the simple harmonic motion in a vertical direction
Damping vibration

Experimental Apparatus
Dynamic support rod
Datalogger Acceleration sensor Gorce sensor
Spring oscillator

ECG Sensor

Art No. 30162.28
Measuring range: -5mV~+5mV
Accuracy: 0.0025mA
Typical Experiment
Measure the human electrocardiogram

Experimental Apparatus
Datalogger
EKG sensor

Gas Pressure Sensor

Art No. 30162.29
Measuring range: 0~700kPa
Resolution: 0.025kPa
Accuracy: ±0.5kPa
Typical Experiment
Boyle's Law
Charles' Law
Study the relation between liquid boiling point and pressure

Experimental Apparatus
Boyle's law experimenter
Datalogger
Gas pressure sensor

Relative Pressure Sensor

Art No. 30162.30
Measuring range: -20kPa~20kPa
Resolution: 0.01kPa
Accuracy: ±0.1kPa
Typical Experiment
Boyle's Law
Charles's Law
Relation between the boiling point and the pressure
Explore the transpiration of plant

Experimental Apparatus
Datalogger
Relative pressure sensor
Charles's law experimenter

Electronic Compass Sensor

Art No. 30162.31
Measuring range: 0~360°
Resolution: 0.1°
Accuracy: 1°
Typical Experiment
Application of simulating compass

Experimental Apparatus
Datalogger
Electronic compass sensor

Conductivit Sensor

Art No. 30162.32
Low measuring range:0~3000μs/cm
Resolution:1μs/cm
Accuracy:±1μs/cm
High measuring range:0~30000μs/cm
Resolution:8μs/cm
Accuracy:±1μs/cm
Typical Experiment
Comparison on the conductivity of different water
Reaction of phenol and saturated bromine water
Study on the purity of drinking water
Relation between cell size and material transport

Experimental Apparatus
Datalogger
Conductivity sensor
Beaker Porous cover
Positioning rubber ring

Turbidimeter Sensor

Art No. 30162.33
Measuring range:0~400NTU
Resolution:0.1NTU
Typical Experiment
Comparison on the turbidity of different water
Study the reaction rate of the sodium thiosulfate and acid

Experimental Apparatus
Datalogger
Turbidimeter
Beaker

Spirometer Sensor

Art No. 30162.34
Measuring range:±10L/S
Resolution:0.01L/s
Typical Experiment
Measurement on the respiratory rate of human
Measurement on vital capacity

Experimental Apparatus
Datalogger
Respiration sensor
Breathing mouthpiece
Airflow head

Drop Counter Sensor

Art No. 30162.35
Measuring range:0~∞c/0~∞ml
Resolution:1c/0.01mL
Accuracy:±1c/±0.1mL
Typical Experiment
Acid-base neutralization titration
Titration experiment of the device similar to the acid
base titration

Experiment Apparatus
Datalogger
Drop counter pH sensor
Neutralization titration device
Magnetic strring device

Light Sensor

Art No. 30162.36
Low measuring range:0~6000LUX
Resolution:1.5LUX
Accuracy:1LUX
High measuring range:0~50000LUX
Resolution:12.5LUX
Accuracy:1LUX
Typical Experiment
Study the relation between illumination intensity and distance
Study the diffraction,interference,polarization of light

Experimental Apparatus
Datalogger
Light sensor
Light source

Light Sensor

Art No. 30162.37
Low measuring range:0~600LUX
Resolution:0.2Lux
Accuracy:±2%
Middle measuring range:0~6000LUX
Resolution:1Lux
Accuracy:±2%
High measuring range:0~150000LUX
Resolution:38LUX
Accuracy:5%
Typical Experiment
Explore the relation between the intensity of illumination
and the distance
Study the diffraction of light,interference of light and
polarization of light
Explore the influence caused by the intensity of
illumination to the photosynthesis rate of plants

Experiment Apparatus
Datalogger
3-measuring range light sensor
Light source Straightedg

CCD Sensor

Art No. 30162.38
Measuring range: 125Dot/mm
Resolution: 125Pix/mm
Accuracy: 0.008mm
Typical Experiment
Interference of light
Diffraction of light
Polarization of light

Experiment Apparatus
Optical Experiment Components
Smart Datalogger
Light Distribution Sensor

NO

Art No. 30162.39
Measuring range: 30V/1A
Typical Experiment
To switch a small bulb on or off with current sensor
To switch a small bulb on or off automatically as per the
brightness around
Control temperature of thermostat automatically

Experimental Apparatus
Datalogger
NO controller Current sensor
Student power supply
Sliding rheostat

NC

Art No. 30162.40
Measuring range: 30V/1A
Typical Experiment
To switch a small bulb on or off with current sensor
To switch a small bulb on or off automatically as per
the brightness around
Control temperature of thermostat automatically

Experimental Apparatus
Datalogger
NC controller Current sensor
Student power supply
Sliding rheostat

Cherge

Art No. 30162.41
Low measuring range: ±22nC
Resolution: 0.01nC
High measuring range: ±220nC
Resolution: 0.01nC
Typical Experiment
Photoelectric effect
Electrostatic phenomenon
Electric charge shares between conductors
Faraday ice bucket experiment
Electrostatic shielding
Number and symbol of electric charges on different objects
Charge density on conductor surface

Experimental Apparatus
Datalogger
Electric charge sensor
Iron stand
Rubber bar

Thermal radiation

Art No. 30162.42
Measuring range: -70℃~380℃
Resolution: 0.01℃
Accuracy: ±0.5℃
Typical Experiment
Measure blackbody radiation
Leslie Tube Experiment
Measure solar radiation
Imitate non-contact temperature sensor

Experimental Apparatus
Datalogger
Thermal radiation sensor
beaker

Products Categories
Why us

FAQ

APP
Post My RFQ
WhatsApp