Contact us For product pricing, customization, or other inquiries:
Contact Us
Product Details
{{item.text}}
Quick Details
Mounting Type:
other
Description:
other, other
Manufacturing Date Code:
other
Model Number:
30162.29
Place of Origin:
Zhejiang, China
Brand Name:
Kelsun
Theory:
other
Output:
other
Sensor:
Gas Pressure Sensor
Measuring range:
0~700kPa
Resolution:
0.025kPa
Accuracy:
±0.5kPa
Quick Details
Use:
other
Series:
other
Features:
other
Mounting Type:
other
Description:
other, other
Manufacturing Date Code:
other
Model Number:
30162.29
Place of Origin:
Zhejiang, China
Brand Name:
Kelsun
Theory:
other
Output:
other
Sensor:
Gas Pressure Sensor
Measuring range:
0~700kPa
Resolution:
0.025kPa
Accuracy:
±0.5kPa
Product Description
Datalogger,TriE Smart
Art No. 30160.11
Portable datalogger with superelevation performance-to-price ratio
TriE Smart is a fully self-contained portable datalogger, which can be used as:
1. A device connected to a computer
2. A stand-alone instrument
Under the stand-alone mode, Smart can:
1. Display the meter readings of the sensor attached
2. Support for data storage, and support for exporting the stored data to a computer
K-Type Temperature(thermocouple sensor)
Art No. 30162.01
Measuring range:-25℃~+100℃
resolution:0.03℃
Accuracy:±0.5℃
Typical Experiment
Cooling water naturally
Liquid's evaporation cooling
Charkes's Law
Change its work and temperature of compressed air
Measuring range:-60mV~+60mV
Resolution:0.03mV
Accuracy:±0.5mV
Internal resistance:1MΩ
Typical Experiment
Lenz's Law
Electromagnetic induction
Faraday's of electromagnetic induction
Experimental Apparatus
Datalogger
Micro voltage sensor Magnetic field sensor
Faraday's law of electromagnetic induction experimenter
Voltage sensor
Art No. 30162.03
Measuring range:-25V~+25V
resolution:0.01V
Accuracy:±0.01V
The voltage sensor is used to measure the electric
potential difference at both ends of the electrical
equipments or circulars.after the circuit of voltage it
collects.then it can realize the measurement.The
voltage sensor can be used in the DC circuit and low
voltage AC circuit.
Typical Experiment
Measure the electrodynamic potential and internal
resistance of power supply
Measure the VA characteristic curve of small bulb,
diode,conductor
Ohm's Law
Serial-parallel circuit of resistance
Electromagnetic induction phenomena and induced
current
LC oscillation
Serial-parallel circuit.charging and discharging of
capacitor
Experiment Equipment
DIS-EX05 LC oscillation circuit
Datalogger
Voltage sensor
Student power supply
Voltage sensor
Art No. 30162.04
Measuring range:-20V~20V -2V~2V -200mV~
200mV
resolution:0.01V 0.001V 0.1mV
Accuracy:±0.01V ±0.01V ±0.5mV
Typical Experiment
Measure the electrodynamic potential and internal
resistance of battery
VA characteristics of small bulb,diode and conductor
Ohm's Law
Serial-parallel circuit of resistance
Electromagnetic induction phenomena
Serial-parallel circuit,charging-discharging of capacitor
Experiment Equipment
Datalogger
Multirange voltage sensor Milli current sensor
DIS-EX12 Measure the electrodynamic potential and
internal resistance of battery circuit
Sliding rheostat
PH meter sensor
Art No. 30162.05
Measuring range:0~14
Resolution:0.003
Accuracy:±0.1
Typical Experiment
Acid-base neutralization titration
pH value of different solutions
Acidity of phenol
Mechanism of organism for maintaining pH stability
Study on impact of pH value on pectinase activity
Art No. 30162.06
Measuring range:0~40000c/min
Typical Experiment
Measurement on common radioactive source counting rate
Measurement on background counting rate
Radioactive shield
Study the relation between radioactive intensity and distance
Measurement on radioactivity of building materials
Experimental Apparatus
Datalogger
G-M sensor
Iron stand
Radioactive source for teaching
Carbon dioxide sensor
Art No. 30162.07
Measuring range: 0 ~100000PPm
Resolution: 2ppm
Accuracy: (0~5000ppm) 3%
(5000~50000ppm) 4%
(50000~100000ppm) 6%
Typical Experiment
Photosynthesis of plant
Study the breathing way of saccharomycetes
Assessment on air quality
Generation velocity of CO2 gas in chemical reaction
Art No. 30162.08
Measuring range:0.000~20.000ppm
Resolution:0.005ppm
Accuracy:±0.1ppm
Typical Experiment
Air quality assessment
Detection of vehicle exhaust
Measure the small quantity of sulphur dioxide generated
by chemical reaction
Trace sodium thiosulfate solution react with concentrated
sulfuric acid
Experimental Apparatus
Datalogger
Sulphur dioxide sensor
Gas bottle
Humidity sensor
Art No. 30162.09
Measuring range:0~100%RH
Resolution:1%RH
Accuracy:0.02%
Typical Experiment
Measurement on the change of environmental humidity
Hydroscopicity of the concentrated sulfuric acid
Design and make an ecological cylinder and observe
its stability
Experimental Apparatus
Datalogger
Humidity sensor
Iron stand
Dovetail clamp
Multi-directional adapter
Test tube
Colorimeter
Art No. 30162.10
Measuring range: 0~100%
Resolution: 0.02%
Accuracy: ±0.2%
Typical Experiment
Impact of concentration on reaction velocity - color - fading
reaction of potassium permanganate and oxalic acid
Impact of temperature on reaction velocity - reaction of
sodium thiosulfate and sulfuric acid
Measurements on the content of Vitamin C in juice
Measurement on concentration of substance in
solution(Beer-Lambert law)
Experimental Apparatus
Datalogger
Colorimeter
Beaker
Current sensor
Art No. 30162.11
Measuring range: -20mA~+20mA
Resolution: 0.01mA
Accuracy: ±0.1mA
Typical Experiment
Charge and discharge the capacitor
Experimental Apparatus
Smart Datalogger
Electrical Experiment Board
Student Power Supply
Current sensor
Art No. 30162.12
Measuring range:-3.0A~+3.0A
Resolution:0.001A
Accuracy:±0.001A
Typical Experiment
Measure the electrodynamic potential and internal
resistance of battery
Measure the VA characteristic curve of small bulb,
diode,conductor
Ohm's Law
Serial-parallel circuit of resistance
Experimental Apparatus
DIS-EX12 Measure the electrodynamic potential and
internal resistance of battery circuit
Datalogger
Voltage sensor Current sensor
Sliding rheostat
Student power supply
Current sensor
Art No. 30162.13
Measuring range:-2A~2A -200mA~200mA
-20mA~20mA
Resolution:0.001A 0.1mA 0.01mA
Accuracy:±0.05A ±0.5mA ±0.05mA
Typical Experiment
Measure the electrodynamic potential and internal resistance
of battery
VA characteristics of small bulb,diode and conductor
Ohm's Law
Serial-parallel circuit of resistance
Electromagnetic induction phenomena
LC oscillation
Serial-parallel circuit,charging-discharging of capacitor
Experimental Apparatus
Datalogger
Multirange current sensor Voltage sensor
DIS-EX07 VA characteristics of conductor
Sliding rheostat
Student power supply
Micro-current sensor
Art No. 30162.14
Measuring range: -10μA~+10μA
Resolution: 0.01μA
Accuracy: ±0.1μA
Typical Experiment
Electromagnetic induction phenomena
Thermoelectric current phenomena
Voltaic cell
Art No. 30162.15
Measuring range:-2000mV~+2000mV
Resolution:1mV
Accuracy:±5mV
Typical Experiment
Detection of industrial wastewater
Sterilization of water and its application
Water quality testing
Experimental Apparatus
Datalogger
Oxidation-reduction sensor
Iron stand
Beaker
Oxygen sensor
Art No. 30162.16
Measuring range: 0~100%
Resolution: 0.02%
Accuracy: ±0.2%
Typical Experiment
Photosynthesis of plant
Compare the decomposition of catalase in different
conditions
Compare the gas exhaled by human with the
environmental gas
Experimental Apparatus
Datalogger
Oxygen sensor CO2 sensor
Breathing mouthpiece
Airflow head
Force sensor
Art No. 30162.17
Measuring range: -50N~+50N
Resolution: 0.01N
Accuracy: ±0.05N
Typical Experiment
Hooke's Law
Newton's Third Law
Theorem of momentum
Metal expands with heat and contracts with cold
Explore the simple harmonic motion
Overweight and weightlessness
Archimedes' Law
Experimental Apparatus
Newton's third law experimenter
Datalogger
Force sensor
Magnetic field sensor
Art No. 30162.18
Range: 64mT~+64mT
Resolution: 0.03mT
Accuracy: 0.03mT
Typical Experiment
Study the magnetic field around the permanent magnet
Measure the axial magnetic field of electrified solenoid
Measure the magnetic field around the electrified wire
Measure the magnetic field of Helmholtz coil
Experimental Apparatus
Datalogger
Magnetic field sensor
Solenoid
Student power supply
Sliding rheostat
Motion sensor
Art No. 30162.19
Measuring range: 20cm~200cm
Resolution: 0.1cm
Typical Experiment
Explore the simple harmonic motion
Forced vibration
Uniform linear motion,uniform variable rectilinear motion
Experimental Apparatus
Datalogger
Motion sensor
Car &rail experimental device
Motion sensor
Art No. 30162.20
TS2117 Range: 40cm~600cm
Resolution: 1mm
Photogate sensor
Art No. 30162.21
Measuring range: 0~∞s
Resolution: 0.01ms
Typical Experiment
Newton's Second Law
Study the pendulum movement
Theorem of momentum
Mechanical Energy Conservation Law
Measure the rotating speed of rotating objects
Study of centripetal force
Study of Atwood machine
Experimental Apparatus
Datalogger
Photogate sensor
Car &rail experimental device
Dissolved oxygen sensor
Art No. 30162.22
Measuring range: 0~20mg/L
Resolution: 0.005mg/L
Accuracy: ±0.2mg/L
Typical Experiment
Study the breathing way of saccharomycetes
Study the dissolved oxygen of different water
Factors that affect plant photosynthesis
Art No. 30162.23
Measuring range: -50℃~150℃
Resolution: 0.05℃
Accuracy: ±0.5℃
Typical Experiment
Cooling water naturally
Liquid's evaporation cooling
Work-to-internal energy conversion
Study the relation between liquid boiling point and pressure
Study the thermoelectricity phenomena
The comparison of different material's heat conduction
performance
The convex lens convergence effect
Experimental Apparatus
Convex lens' ray convergence experimenter
Datalogger
Temperature sensor
Light source
High-Temperature Sensor
Art No. 30162.24
Measuring range: -200℃~1200℃
Resolution: 0.3℃
Accuracy: ±0.1℃
Typical Experiment
Study on the melting point of crystal
Measurement on temperature of flame
Liquid cooling via evaporation
Study on relation between boiling point and pressure of liquid
Study on the thermoelectricity phenomenon
Comparison on heat conduction performance of different
substances
Experimental Apparatus
Datalogger
Hight temperature sensor
Alcohol lamp
Surface Temperature Sensor
Art No. 30162.25
Measuring range: -30℃~150℃
Resolution: 0.05℃
Accuracy: ±0.5℃
Typical Experiment
The conversion between power and energy
comparison on thermal conductivity of different objects
Experimental Apparatus
Datalogger
Surface temperature sensor
Friction working experimenter
Cotton string
Sound Sensor
Art No. 30162.26
Low range: 30~90dB
Resolution: 0.1dB
High range: 80~120dB
Resolution: 0.1dB
Sound wave
Measuring range:20Hz~20kHz
Typical Experiment
Measure the level of sound intensity
Measure the environmental intensity of noise
Measure the velocity of sound in the air
Synthesis of sound wave
Art No. 30162.27
Measuring range: -6g~6g
Resolution: 0.003g
Accuracy: ±0.01g
Typical Experiment
Study the Newton's Law of Motion
Study the centripetal acceleration
Explore the resonance phenomena
Study the simple harmonic motion in a vertical direction
Damping vibration
Experimental Apparatus
Dynamic support rod
Datalogger Acceleration sensor Gorce sensor
Spring oscillator
ECG Sensor
Art No. 30162.28
Measuring range: -5mV~+5mV
Accuracy: 0.0025mA
Typical Experiment
Measure the human electrocardiogram
Experimental Apparatus
Datalogger
EKG sensor
Gas Pressure Sensor
Art No. 30162.29
Measuring range: 0~700kPa
Resolution: 0.025kPa
Accuracy: ±0.5kPa
Typical Experiment
Boyle's Law
Charles' Law
Study the relation between liquid boiling point and pressure
Experimental Apparatus
Boyle's law experimenter
Datalogger
Gas pressure sensor
Relative Pressure Sensor
Art No. 30162.30
Measuring range: -20kPa~20kPa
Resolution: 0.01kPa
Accuracy: ±0.1kPa
Typical Experiment
Boyle's Law
Charles's Law
Relation between the boiling point and the pressure
Explore the transpiration of plant
Experimental Apparatus
Datalogger
Relative pressure sensor
Charles's law experimenter
Electronic Compass Sensor
Art No. 30162.31
Measuring range: 0~360°
Resolution: 0.1°
Accuracy: 1°
Typical Experiment
Application of simulating compass
Art No. 30162.32
Low measuring range:0~3000μs/cm
Resolution:1μs/cm
Accuracy:±1μs/cm
High measuring range:0~30000μs/cm
Resolution:8μs/cm
Accuracy:±1μs/cm
Typical Experiment
Comparison on the conductivity of different water
Reaction of phenol and saturated bromine water
Study on the purity of drinking water
Relation between cell size and material transport
Art No. 30162.33
Measuring range:0~400NTU
Resolution:0.1NTU
Typical Experiment
Comparison on the turbidity of different water
Study the reaction rate of the sodium thiosulfate and acid
Art No. 30162.34
Measuring range:±10L/S
Resolution:0.01L/s
Typical Experiment
Measurement on the respiratory rate of human
Measurement on vital capacity
Experimental Apparatus
Datalogger
Respiration sensor
Breathing mouthpiece
Airflow head
Drop Counter Sensor
Art No. 30162.35
Measuring range:0~∞c/0~∞ml
Resolution:1c/0.01mL
Accuracy:±1c/±0.1mL
Typical Experiment
Acid-base neutralization titration
Titration experiment of the device similar to the acid
base titration
Experiment Apparatus
Datalogger
Drop counter pH sensor
Neutralization titration device
Magnetic strring device
Light Sensor
Art No. 30162.36
Low measuring range:0~6000LUX
Resolution:1.5LUX
Accuracy:1LUX
High measuring range:0~50000LUX
Resolution:12.5LUX
Accuracy:1LUX
Typical Experiment
Study the relation between illumination intensity and distance
Study the diffraction,interference,polarization of light
Art No. 30162.37
Low measuring range:0~600LUX
Resolution:0.2Lux
Accuracy:±2%
Middle measuring range:0~6000LUX
Resolution:1Lux
Accuracy:±2%
High measuring range:0~150000LUX
Resolution:38LUX
Accuracy:5%
Typical Experiment
Explore the relation between the intensity of illumination
and the distance
Study the diffraction of light,interference of light and
polarization of light
Explore the influence caused by the intensity of
illumination to the photosynthesis rate of plants
Experiment Apparatus
Datalogger
3-measuring range light sensor
Light source Straightedg
CCD Sensor
Art No. 30162.38
Measuring range: 125Dot/mm
Resolution: 125Pix/mm
Accuracy: 0.008mm
Typical Experiment
Interference of light
Diffraction of light
Polarization of light
Experiment Apparatus
Optical Experiment Components
Smart Datalogger
Light Distribution Sensor
NO
Art No. 30162.39
Measuring range: 30V/1A
Typical Experiment
To switch a small bulb on or off with current sensor
To switch a small bulb on or off automatically as per the
brightness around
Control temperature of thermostat automatically
Experimental Apparatus
Datalogger
NO controller Current sensor
Student power supply
Sliding rheostat
NC
Art No. 30162.40
Measuring range: 30V/1A
Typical Experiment
To switch a small bulb on or off with current sensor
To switch a small bulb on or off automatically as per
the brightness around
Control temperature of thermostat automatically
Experimental Apparatus
Datalogger
NC controller Current sensor
Student power supply
Sliding rheostat
Cherge
Art No. 30162.41
Low measuring range: ±22nC
Resolution: 0.01nC
High measuring range: ±220nC
Resolution: 0.01nC
Typical Experiment
Photoelectric effect
Electrostatic phenomenon
Electric charge shares between conductors
Faraday ice bucket experiment
Electrostatic shielding
Number and symbol of electric charges on different objects
Charge density on conductor surface
Experimental Apparatus
Datalogger
Electric charge sensor
Iron stand
Rubber bar
Thermal radiation
Art No. 30162.42
Measuring range: -70℃~380℃
Resolution: 0.01℃
Accuracy: ±0.5℃
Typical Experiment
Measure blackbody radiation
Leslie Tube Experiment
Measure solar radiation
Imitate non-contact temperature sensor