Products
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector
Conventional Smoke Detector  Photoelectric Fire Alarm Cigarette Smoke Detector

Conventional Smoke Detector Photoelectric Fire Alarm Cigarette Smoke Detector

FOB Reference Price: Get Latest Price
≥100 Pieces
US $4
Free Inquiry
Customized Request
  • Product Details
  • {{item.text}}

Quick Details

Operating Voltage Range:
9 to 28 VDC Volts Non-polarized
Standby Current:
≤60uA@24VDC
Maximum Alarm Current:
≤30mA@24VDC (1K Ohm current-limiting resistance)
Operating Temperature Range:
-10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity:
0.15-0.3dB/m
Height:
48 mm installed in Base
Diameter:
99 mm
Certification:
CE

Quick Details

Place of Origin:
Guangdong, China
Brand Name:
Risol
Model Number:
CSD81
Operating Voltage Range:
9 to 28 VDC Volts Non-polarized
Standby Current:
≤60uA@24VDC
Maximum Alarm Current:
≤30mA@24VDC (1K Ohm current-limiting resistance)
Operating Temperature Range:
-10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity:
0.15-0.3dB/m
Height:
48 mm installed in Base
Diameter:
99 mm
Certification:
CE
Product Description
Overview This smoke detector can be used in all areas where photoelectric smoke detector is required. It is suitable for fires ranging from smoldering to flaming fires. This smoke detector is designed to provide open area protection and to be used with any conventional fire alarm control panel. Two LED lights on each detector provide local 360° visible for indication of status. In the normal condition the LED lights flash red every 5 seconds. When the detector senses smoke goes into pre-alarm sensitivity the LED lights will flash red every 1 second. When the detector goes into alarm the LED lights will light on red. The alarm can be reseted only by a momentary power interruption.
Item
Value
Operating Voltage Range
9 to 28 VDC Volts Non-polarized
Standby Current
≤60µA@24VDC
Maximum Alarm Current
≤30mA@24VDC (1K Ohm current-limiting resistance)
Operating Temperature Range
-10°C to 50°C (14°F to 122°F)
Smoke Alarm Sensitivity
0.15-0.3dB/m
Height
48 mm installed in Base
Diameter
99 mm
Specification
Packing & Delivery
APP
Post My RFQ
WhatsApp
+86-17326049340