- Product Details
- {{item.text}}
Quick Details
-
Place of Origin:
-
Guangdong, China
-
Engine:
-
Cummins diesel engine
-
Alternator:
-
Stamford,LeroySomer, Marathon
-
Control panel:
-
Electric start
-
Cooling System:
-
Water cooled
-
Power factor:
-
0.8
-
Insulation class:
-
H
-
Protection class:
-
IP21-23
-
After-sales Service Provided:
-
engineers available to service machinery overseas
-
Certificates:
-
ISO9001:2008, CE,
Quick Details
-
Rated Voltage:
-
120V, 230V/400V, 240V/415V
-
Rated Current:
-
1800A
-
Frequency:
-
50Hz or 60Hz
-
Place of Origin:
-
Guangdong, China
-
Engine:
-
Cummins diesel engine
-
Alternator:
-
Stamford,LeroySomer, Marathon
-
Control panel:
-
Electric start
-
Cooling System:
-
Water cooled
-
Power factor:
-
0.8
-
Insulation class:
-
H
-
Protection class:
-
IP21-23
-
After-sales Service Provided:
-
engineers available to service machinery overseas
-
Certificates:
-
ISO9001:2008, CE,
Project construction Heavy duty Electricity power 1 Megawatt Generator
1. Genuine industrial diesel engine
2. Radiator 50°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 10-hour operation base tank
Technical data |
|
Genset Model |
GNRC1000 |
Prime Power |
1000KW/1250KVA |
Rated Voltage |
400/230V |
Frequency |
50/60Hz |
Power Factor |
0.8(lagging) |
The regulating rate of steady voltage |
≤±0.5% |
The regulating rate of instantaneous voltage |
≤-15%/ +20% |
The time of steady voltage |
≤1.5sec |
The waving rate of voltage |
≤1.0% |
The regulating rate of steady frequency |
≤3% |
The regulating rate of instantaneous frequency |
≤±10% |
The time of steady frequency |
3sec |
Dimension (L×W×H) (mm) |
5300*2100*2500 |
Genset weight (kg) |
10000 |
Diesel Engine |
|
Brand |
Cummins |
Model |
KTA50-G3 |
Number of Cylinders |
16 |
Rotating Speed |
1500/18000RPM |
Cycle |
Four stroke |
Type |
waste gas turbine boost,direct spurting type |
Bore×Stroke(mm) |
159*159 |
Displacement(L) |
50 |
Lubricating Capacity(L) |
204 |
Speed Governor |
Electrical |
Cooling System |
Water-cooled |
Speed Stability (%) |
≤5% |
Fuel Consumption at 100% Load |
205g/kw.h |
Starting Method |
DC24V Electrical starting |
Alternator |
|
Brand |
Stamford |
Model |
LVI634G |
Number of Phase |
3 |
Connecting Type |
Three Phase and Four Lines |
Number of Bearing |
1 |
Grading Protection |
IP23 |
Altitude |
≤1000m |
Exciter Type |
Brushless (AVR automatic voltage regulating) |
Insulation Class |
H degree |
The components of the genset |
|
(1) Cummins Diesel Engine; (2)Stamford Alternator; (3) Control Panel |
|
Control Panel |
|
The control panel is Quadruplication protection control panel, with the display of frequency table/water temperature/schedule/battery voltmeter. The genset with low oil pressure, high water temperature, over speed emergency, stop and other pre-protection |
1. Optional Accessories of 1 Megawatt Generator
1) ATS ( Automatic Transfer switch);
Which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator.
And ATS have the function of AMF (automatic Main power failure)
2) MCCB (Molded case circuit breaker);
It can protect the loading machine and the diesel generator.
3) Battery charger (float charger);
When the generator hasn’t been used for a long time, the batteries will be no power, in that way, you can’t start the generator. But the battery charger can charge the batteries from main power.
4) Extra daily fuel tank ;
It will be requested while the base fuel tank capacity is not enough for daily fuel consumption.
5) Paralleling system ;
This system can make several generators work together and automatically distribute the load according to set.
6) Remote Control Panel ;
Which can control the generator by computer, if use a RS484 or RS232 digital cable to connect the generator to the computer.
7) Water separate (additional cooling system);
If the ambient temperature is too high, it will be harmful to the diesel generator. Fan and water cooling is not enough for radiate. The water separate system is much better for cooling, and the life of generator will be much longer.
8) Spare Parts of Cummins engine;
All the spare parts of each Cummins engine are supplied at very competitive price.
1. what is the warranty ?
the standard warranty is 12months or 1000 running hours, subject to the earlier mature term.
but we will offer life-time and free technological support and problem solutions.
During warranty , if any problem , the spare parts supplying will be free .
2. how do we install the generator in our place ?
before delivering the generators , our engineers have installed and checked everyhing well.
when you receive the generator , you just need to fill the cooling water ,lube oil and fuel ,
then you just push the start button ,the generator will be running automatically. your local technician also know it well .
3. What is the generator maintenance period ?
you should do the maintenances according to the manual book , your local technician can do it easily .
4.What is your MOQ, payment method, delivery time?
Our MOQ is only 1 set.
Payment method usually is 30% T/T as deposit, 70% balance T/T before delivering. Or 100% L/C.
Welcome to place the order through the trade assurance of Alibaba.
Delivery period normally will be 15~20 days after receiving customers' deposit.
5. Can you offer OEM service and print our logo in your genertator ?
Yes. Please inform us formally before our production.