- Product Details
- {{item.text}}
Quick Details
-
height measure range:
-
70.0~200cm
-
Blood pressure monitor range:
-
0 mmHg to 280 mmHg
-
blood oxygen measure range:
-
35%~100%
Quick Details
-
Place of Origin:
-
Guangdong, China
-
Brand Name:
-
INBCA
-
weight measure range:
-
500kgs
-
height measure range:
-
70.0~200cm
-
Blood pressure monitor range:
-
0 mmHg to 280 mmHg
-
blood oxygen measure range:
-
35%~100%
Product Description
Health Care Check Kiosk All in One Body Check Station Overall Solution for Public Health Medical System
A comprehensive type of integrated system, including a variety of medical examination equipment and unified information processing software, can provide customers with more then ten kinds of normal medical examinations,and can collect data from various testing instruments together for unified processing and reporting to the cloud platform, widely used in chain of medical examination centers, health management institutions,health cabin equipment integration.
Specification
Body weight measurement
|
Measuring system
|
Resistance strain gauge
|
|
Body weight index
|
Automatic intelligent calculation of body mass index
|
||
Range of measurement
|
500kg
|
||
Height measurement
|
Verified precision
|
±0.1kg
|
|
Measuring system
|
Ultrosonic probe
|
||
Range of measurement
|
70.0~200cm
|
||
Verified precision
|
0.1cm
|
||
Blood pressure measurement
|
Model
|
Panasonic EW3153 Arm cuff
|
|
Display
|
LCD Digital Display
|
||
Measurement Method
|
Oscillometric method
|
||
Measurement Range
|
Pressure: 0 mmHg to 299 mmHg, Pulse: 40 to 180/min.
|
||
Accuracy
|
Pressure: ±3 mmHg, Pulse: ± 5%
|
||
Inflation
|
Electric pump
|
||
Deflation
|
Automatic pressure release valve
|
||
Pressure Detection
|
Capacitive pressure sensor
|
||
Memory
|
84 Measurements with date and time for each user
|
||
(A and B)
|
|||
Power Source
|
AC/DC adapter (Included; Input 100-240V 50Hz/60Hz,
|
||
AC/DC adapter (Included; Input 100-240V
|
Output 6V/9.6W)
|
||
50Hz/60Hz,Output 6V/9.6W)
|
10°C to 40°C/30 to 85% RH
|
||
Storage temperature/Humidity/Air Pressure
|
-20°C to 60°C/10 to 95% RH700 - 1060 hPa
|
||
Console Weight
|
Approximately 2600 g
|
||
Outer Dimensions
|
Approximately 286 (l) mm * 294 (w) mm * 271 (h) mm
|
||
Arm Circumference
|
22 to 42 cm
|
||
Measurement of fat
|
Measuring system
|
Multi-frequency 4- Electrode
|
|
Measurement frequency
|
5kHz/50kHz/250kHz/500kHz
|
||
Measurement category
|
Body fat, Muscle, Visceral fat, Body water, Basal metabolism, Body Type
|
||
Material
|
Electroplating material
|
||
Current for measurement
|
90μA or below
|
||
Range of measurement
|
75.0~1,500.00Ω(0.1ΩUnit)
|
||
Body parts of surveyor
|
Body, right leg, left leg, right arm, left arm
|
||
Measurement of blood oxygen
|
Blood oxygen probe
|
CREATIVE KS-CM01
|
|
Sensor
|
Dual wavelength LED
|
||
Wavelength
|
"Visible light( Max):663nm
|
||
Invisible Light:890nm"
|
|||
Measurement range
|
35%~100%
|
||
Average output power(Max)
|
≤2mW
|
||
Measurement error
|
In the range of 70% to 100% < ±2%
|
||
Accuracy
|
In the range of 70% to 100% < ±3%
|
||
Pulse rate measurement error
|
30~250bpm
|
||
Monitoring error is ±2bpm or ±%2, whichever is the
|
|||
largest
|
|||
Working humidity
|
5℃~40℃
|
||
Relative humidity
|
15%~95%(Non-condensing)
|
||
Atmospheric pressure
|
70kpa~106kpa
|
||
Power supply mode
|
Powered by ancillary equipment
|
||
Range of measurement
|
95-99%(±2%normal status,±3% motion or weak perfusion,less than 95% undefined)
|
||
Body temperature
|
Infrared thermometer
|
Calibeur DT-8836
|
|
Accuracy
|
0.1 ℃
|
||
Operating Temperature
|
10~40℃
|
||
Storage temperature
|
0~50℃
|
||
Relative humidity
|
≤85%
|
||
Power supply
|
DC 9V(6F22:a layer-built battery)
|
||
Specification
|
150*75*40mm
|
||
Weight
|
Gross weight:400g, Net weight:172g
|
||
Body temperature range
|
32.0~42.5℃
|
||
Object temperature range
|
0~100℃
|
||
Accuracy
|
≤±0.3℃
|
||
Power dissipation
|
≤120mw
|
||
Measurement distance
|
5-8cm
|
||
Auto power off
|
About 15 seconds
|
Detailed Image
Advantage
A.Human data model (body composition model)
B.DSM-BIA technology
C.Lot intelligent networking technology
D.AI deep learning and algorithm optimization technology
E.High-performance intelligent gateway technology
F.Face image identification technology
G.HDR data optimization acquisition technology
H.Multi-language selection, free switching between bilingual screens
DSM-BIA Technology
Integrated Solution for Public Health Medical System
Our health check-up kiosk can connect to Public Health Medical System .
The overall solution for the public health medical system refers to a collection of solutions designed to improve the efficiency and quality of public health and medical services. These solutions typically include:
System architecture and design: Design and build information system architecture and databases based on the needs and actual situation of public health and medical services to ensure system stability and reliability.
Data collection and management: Collect and manage relevant public health and medical data through various means, including disease monitoring, epidemiological investigations, medical records, etc., for data analysis and research.
Data analysis and mining: Utilize technologies such as data mining and artificial intelligence to analyze and mine public health and medical data, identify potential health problems and risks, and provide more accurate medical services and management.
Integration and optimization of medical resources: Improve the efficiency and quality of public health and medical services through the integration and optimization of medical resources, including medical facilities, personnel, and equipment.
Technological innovation and application: Promote innovation and application in public health and medical services through the application of the latest technologies, such as remote medical care, mobile medical care, intelligent medical care, etc.
Security and privacy protection: Ensure the security and privacy protection of the public health medical system to avoid security risks such as personal information leakage and cyber attacks.
These are some of the main contents of the overall solution for the public health medical system. Specific solutions may vary due to factors such as region, culture, and economy.
Product Packing
Usage Notice
Certificates